Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100000pieces per year |
Delivery Time | within 15days |
Packaging Details | Standard export package |
Cooling capacity | 18KW~4000KW |
Refrigerant | R134a |
Refrigerating medium | Sulfate solution |
Shell material | Seamless steel pipe |
Application | Refrigeration industry |
Type | shell and tube type |
Brand Name | GREEFOUN |
Model Number | QX-310M |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
R404A Flooded Type Evaporator
Full Liquid Type R22 Water Cooled Evaporator Flooded Heat Exchanger
Chiller Water Cooled Full Liquid Type Heat Exchanger Vapour Condenser
R22 Flooded Heat Exchanger
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100000pieces per year |
Delivery Time | within 15days | Packaging Details | Standard export package |
Cooling capacity | 18KW~4000KW | Refrigerant | R134a |
Refrigerating medium | Sulfate solution | Shell material | Seamless steel pipe |
Application | Refrigeration industry | Type | shell and tube type |
Brand Name | GREEFOUN | Model Number | QX-310M |
Certification | CE | Place of Origin | CHINA |
High Light | flooded shell and tube evaporator ,tube shell heat exchanger |
Refrigeration Industry Water Cooling
Flooded Type Evaporator
The "full liquid" refers to the unit used in the "shell and tube evaporator" using a "full liquid evaporator" in
the form, which is different from the "dry", "falling film" of a shell and tube Evaporator.
Its "shell" inside the refrigerant cycle, "pipe" to take the chilled water cycle, from the profile point of view,
as if there are half of the cylinder tube refrigerant, and the water pipe bundle soaked in the refrigerant. It
is the opposite of the "dry evaporator", dry type is "pipe" to take the refrigerant, "shell" water, like the
refrigerant tube soaked in water.
Full-liquid evaporator, and full-liquid unit, than the dry evaporator / dry unit heat transfer efficiency is
higher, the water temperature and the temperature difference between the temperature difference is
small, along the resistance is small, suitable for large circulation Of the unit (such as centrifuges), cooling
effect is good.
But the refrigerant charge requirements, and the need for a dedicated oil return system to help the
compressor back to the oil.
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(SINGLE CIRCUIT) CAPACITY: 350KW TO 650KW
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 350 | 370 | 410 | 460 | 530 | 570 | 650 | |
Heating capacity (KW) | 400 | 445 | 480 | 540 | 630 | 690 | 730 | ||
Wa | m3/h | 61 | 63.5 | 71 | 80 | 91.5 | 98.6 | 112.3 | |
Wb | m3/h | 76 | 80 | 88.5 | 100 | 114.3 | 123 | 141 | |
Dpn | bar | 0.53 | 0.55 | 0.51 | 0.52 | 0.55 | 0.60 | 0.61 |
Models | QX-350M | QX-370M | QX-410M | QX-460M | QX-530M | QX-570M | QX-650M | |
Dimension(mm) | A | 2050 | 2050 | 2050 | 2050 | 2350 | 2350 | 2540 |
A1 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
A2 | 350 | 350 | 380 | 380 | 380 | 380 | 380 | |
L1 | 2200 | 2200 | 2200 | 2200 | 2500 | 2500 | 2690 | |
B | 1140 | 1140 | 1300 | 1300 | 1300 | 1300 | 1300 | |
B1 | 600 | 600 | 680 | 680 | 680 | 680 | 680 | |
C1 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
C2 | 808 | 808 | 870 | 870 | 870 | 870 | 870 | |
D1 | 355 | 355 | 426 | 426 | 426 | 426 | 426 | |
D2 | 426 | 426 | 480 | 480 | 480 | 480 | 480 | |
H1 | 280 | 280 | 300 | 300 | 300 | 300 | 300 | |
H2 | 240 | 240 | 260 | 260 | 260 | 260 | 260 | |
Inlet/Outlet (diameter) Connection | a/b(DN) | 125 | 125 | 150 | 150 | 150 | 150 | 150 |
c1-2 (mm) | 35 | 35 | 35 | 35 | 42 | 42 | 42 | |
d1(mm) | 80 | 92 | 92 | 92 | 92 | 92 | 92 | |
d2(mm) | 54 | 67 | 67 | 67 | 67 | 80 | 80 | |
Corresponding external oil | Volume (L) | 45 | 50 | 55 | 60 | 65 | 70 | 75 |
Weight | P (KG) | 451 | 580 | 690 | 786 | 920 | 1028 | 1150 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(SINGLE CIRCUIT) CAPACITY: 700KW TO 1800KW
Models | QX-700M | QX-820M | QX-950M | QX-1100M | QX-1300M | QX-1500M | QX-1800M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 700 | 820 | 950 | 1100 | 1300 | 1500 | 1800 | |
Heating capacity (KW) | 810 | 950 | 1120 | 1350 | 1625 | 1875 | 2250 | ||
Wa | m3/h | 121 | 141.5 | 164 | 190 | 224 | 258.5 | 310 | |
Wb | m3/h | 151 | 177 | 205 | 237 | 280 | 323 | 387 | |
Dpn | bar | 0.63 | 0.65 | 0.68 | 0.72 | 0.76 | 0.79 | 0.86 |
Models | QX-700M | QX-820M | QX-950M | QX-1100M | QX-1300M | QX-1500M | QX-1800M | |
Dimension(mm) | A | 2710 | 2710 | 2710 | 2710 | 2710 | 2850 | 3050 |
A1 | 500 | 500 | 550 | 550 | 550 | 550 | 550 | |
A2 | 400 | 400 | 450 | 450 | 450 | 450 | 450 | |
L1 | 2860 | 2860 | 2860 | 2860 | 2860 | 3000 | 3200 | |
B | 1420 | 1420 | 1580 | 1580 | 1670 | 1670 | 1670 | |
B1 | 740 | 740 | 820 | 820 | 860 | 860 | 860 | |
C1 | 920 | 920 | 1003 | 1003 | 1053 | 1053 | 1053 | |
C2 | 920 | 920 | 1003 | 1003 | 1053 | 1053 | 1053 | |
D1 | 480 | 480 | 566 | 566 | 616 | 616 | 616 | |
D2 | 530 | 530 | 616 | 616 | 666 | 666 | 666 | |
H1 | 350 | 350 | 420 | 420 | 420 | 420 | 420 | |
H2 | 280 | 280 | 380 | 380 | 420 | 420 | 420 | |
Inlet/Outlet (diameter) Connection | a/b(DN) | 200 | 200 | 250 | 250 | 250 | 250 | 250 |
c1-2 (mm) | 42 | 42 | 42 | 42 | 54 | 54 | 54 | |
d1(mm) | 92 | 105 | 105 | 105 | 105 | 105 | 105 | |
d2(mm) | 80 | 80 | 80 | 92 | 92 | 92 | 92 | |
Corresponding external oil | Volume (L) | 85 | 100 | 110 | 160 | 200 | 240 | 300 |
Weight | P (KG) | 1360 | 1580 | 1790 | 1930 | 2270 | 2480 | 2660 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL
(DOUBLE CIRCUIT) CAPACITY: 800KW TO 2200KW
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | QX-1900M | QX-2200M | ||
Refrigerant R22 (or other environmental refrigerants) | Refrigerating capacity (KW) | 800 | 960 | 1200 | 1380 | 1600 | 1900 | 2200 | |
Heating capacity (KW) | 950 | 1140 | 1400 | 1650 | 2000 | 2380 | 2650 | ||
Wa | m3/h | 138 | 165.5 | 207 | 238 | 276 | 327.5 | 379 | |
Wb | m3/h | 192 | 206 | 259 | 297 | 344 | 400 | 473 | |
Dpn | bar | 0.71 | 0.73 | 0.75 | 0.76 | 0.79 | 0.82 | 0.84 |
Models | QX-800M | QX-950M | QX-1200M | QX-1380M | QX-1600M | QX-1900M | QX-2200M | |
Dimension(mm) | A | 3909 | 3909 | 3909 | 3909 | 4245 | 4245 | 4245 |
A1 | 450 | 500 | 500 | 500 | 500 | 500 | 500 | |
A2 | 360 | 400 | 400 | 400 | 400 | 400 | 400 | |
L1 | 2032 | 2032 | 2032 | 2032 | 2200 | 2200 | 2200 | |
B | 1340 | 1440 | 1470 | 1470 | 1470 | 1570 | 1570 | |
B1 | 690 | 740 | 755 | 755 | 755 | 805 | 805 | |
C1 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
C2 | 925 | 975 | 1008 | 1008 | 1008 | 1058 | 1058 | |
D1 | 426 | 480 | 480 | 480 | 480 | 530 | 530 | |
D2 | 480 | 530 | 566 | 566 | 566 | 616 | 616 | |
H1 | 300 | 350 | 350 | 350 | 350 | 350 | 350 | |
H2 | 260 | 280 | 280 | 280 | 280 | 350 | 350 | |
Inlet/Outlet (diameter) Connection | a/b(DN) | 150 | 200 | 200 | 200 | 200 | 200 | 200 |
c1-4 (mm) | 35 | 42 | 42 | 42 | 42 | 42 | 42 | |
d1-2(mm) | 92 | 92 | 92 | 92 | 92 | 92 | 105 | |
D3-4(mm) | 67 | 67 | 67 | 80 | 80 | 80 | 80 | |
Corresponding external oil | Volume (L) | 90*2 | 95*2 | 100*2 | 110*2 | 130*2 | 160*2 | 180*2 |
Weight | P (KG) | 1745 | 2006 | 2570 | 2780 | 3140 | 3480 | 3610 |
Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C. |
COOPERATED CLENTS
Company Details
Business Type:
Manufacturer
Year Established:
2003
Total Annual:
14,000,000.00-15,000,000.00
Employee Number:
150~200
Ecer Certification:
Active Member
WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ... WUHAN QIAOXIN REFRIGERATION EQUIPMENT CO., LTD. was founded in 2003, located in Wuhan Hubei province, which is a professional manufacturing enterprise dedicated to R&D, design, production and marketing of shell and tube condenser, evaporator and heat exchanger products ...