Payment Terms | T/T, L/C, Western Union |
Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment |
Packaging Details | export package / Negotiate |
Uc | 275V |
Condition | 100% Original |
CertificationCE,CQC | CE / CQC / SGS |
System voltage | 220V |
Environment temperature | (-25℃~+60℃) |
Status indicator | Green(good)/red(need replacement) |
Response time (L-N) | ≤100ns |
Protection rating | IP 20 |
Iimp(10/350μs) | 25ka |
In(8/20μs) | 100kA |
Type | I |
Brand Name | Uchi |
Model Number | OBV-I25-2 |
Certification | CE / SGS / ISO9001 |
Place of Origin | Dongguan China |
View Detail Information
Explore similar products
275VAC Power Surge Protection Device , Class 1 Surge Protection EN 61643-11
AC 100KA Power Surge Protection Device Low Voltage IEC61643-1
Single Phase AC Power Surge Protection Device 385V Limp 15KA
60KA Type 2 Power Surge Protection Device EN 61643-11
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 60000 pieces per month |
Delivery Time | 5-15 days after payment | Packaging Details | export package / Negotiate |
Uc | 275V | Condition | 100% Original |
CertificationCE,CQC | CE / CQC / SGS | System voltage | 220V |
Environment temperature | (-25℃~+60℃) | Status indicator | Green(good)/red(need replacement) |
Response time (L-N) | ≤100ns | Protection rating | IP 20 |
Iimp(10/350μs) | 25ka | In(8/20μs) | 100kA |
Type | I | Brand Name | Uchi |
Model Number | OBV-I25-2 | Certification | CE / SGS / ISO9001 |
Place of Origin | Dongguan China | ||
High Light | Type I Surge Protection Device SPD ,Iimp 25kA Surge Protection Device SPD ,Multilayer Graphite Ignition Structure SPD Device |
Uc(maximum continuous operating voltage) | 275V |
Iimp(impulse discharge current for class I test) | 25kA |
In(nominal discharge current for class II test) | 100kA |
Up(voltage protection level) | ≤2.0kv |
response time | ≤100ns |
Housing Material | thermoplastic material |
Housing self-extinguishing class | UL94_V0 |
Temperature range | -40℃~+80℃ |
Humidity range | 5%RH~95%RH |
Elevational | ≤3000m |
Method of connecting wire | multiple (Connect In Parallel ) |
Mounting method | DIN:35mm |
IP(degree of protection of enclosure) | IP20 |
Application standard | GB18802-1;IEC61643-1 |
Product features:
1. Multilayer graphite ignition structure
2. Integrated surge protector unit
3. Withstand up to 50kA (10/350 μs) of lightning strike
4. Action response time is less than 100ns
Surge protection device T1,T2,T3 relative info
1. According to the definition of IEC61643.1 standard: base on the application environment and test requirements, it can be divided into class I test, class II test and class III test, which are identified as "T1", "T2" and "T3". The test waveforms weremaximum impulse current Iimp (10/350μs); In (8/20μs), impulse voltage of 1.2/50μs. The energy difference between T1 and T2 is huge, T1 being hit directly and T2 being affected by the shock wave
2. From the point of view of the product analysis, as to T1, T2 and T3 level lightning protection device can not be used "advantage" and "disadvantage" to distinguish good or bad, because these lightning protection device each with different use. These can be compared according to the environment and energy used. T1 is applied environment LPZ0A or LPZ0B and LPZ1 interface area, used for lightning high incidence area, lightning current intensity is large level I protection. According to the building lightning protection code, Class I buildings should have T1 SPD of no less than 12.5kA (10/350μs), and local laws and regulations will have more stringent requirements, T1 SPD impulse current will be larger, and T2 SPD should not be less than 60kA (8/20μs). The SPD installation of II and III buildings is different.
3. Class T2 and Class T3 should be installed base on the way of gradual weakening of lightning protection energy and the required configuration of insulation and voltage resistance of protection equipment. For example, the T2 class and T3 class SPD can achieve low residual pressure and more effective protection for equipment. These lightning protection devices have different uses, can be configured according to the appropriate situation of lightning protection device
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
1,500,000-2,500,000
Employee Number:
138~168
Ecer Certification:
Verified Supplier
Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China. After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...
Get in touch with us