China Water - Cooled Plate Accessory Flow Divider Fitting Shunt Liquid Cooling Plate
China Water - Cooled Plate Accessory Flow Divider Fitting Shunt Liquid Cooling Plate

  1. China Water - Cooled Plate Accessory Flow Divider Fitting Shunt Liquid Cooling Plate

Water - Cooled Plate Accessory Flow Divider Fitting Shunt Liquid Cooling Plate

  1. MOQ: 100pcs
  2. Price: Dollars
  3. Get Latest Price
Payment Terms T/T,paypal, Western Union,MoneyGram
Supply Ability 50000000pcs per Month
Delivery Time not limited
Material CU1020
size 250x150x15mm
Weight 2.5 kg
Technology CNC machining
Feature Good cooling capability and No leakage default
Surface treatment oil cleared,cleaned and passivation
Heat conducting power 1300W
Brand Name Uchi
Model Number Heat Sink
Certification SMC
Place of Origin Dongguan,Guangdong,China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,paypal, Western Union,MoneyGram Supply Ability 50000000pcs per Month
Delivery Time not limited Material CU1020
size 250x150x15mm Weight 2.5 kg
Technology CNC machining Feature Good cooling capability and No leakage default
Surface treatment oil cleared,cleaned and passivation Heat conducting power 1300W
Brand Name Uchi Model Number Heat Sink
Certification SMC Place of Origin Dongguan,Guangdong,China
High Light water-cooled liquid cooling plateflow divider fitting shuntliquid cooling plate accessory

Model: OMWH12-H-6-IR-A

 
Version: V1.0
 
Date: 2026-XX-XX
 
Application Scenarios: Electronic liquid cooling systems, high-power industrial power supplies, charging pile BMS, industrial control current sensing
 

1. Product Overview

 
This product is a customized Kelvin lead-type power shunt resistor. It adopts an integrated welding structure of high-conductivity copper alloy resistive element and electrolytic copper bracket.
 
It features low resistance, high current carrying capacity, and high-precision sampling, specially designed for industrial current sensing at hundreds of amperes, suitable for harsh high-temperature and high-vibration working conditions.
 
  1. Welding: Bracket and copper alloy resistive element welded on non‑sheared surfaces; no gaps, cold joints or false welds. Pickling before welding, passivation after welding.
  2. Appearance: Flat, smooth and uniform surface; no burrs, burns, slag, contamination or cracks.
  3. Encapsulation: Welded areas covered with transparent heat‑shrink tube, tight and wrinkle‑free. Leads firmly fixed, color coding clear.
 

6. Test & Acceptance Criteria

 
  1. Factory Test: 100% inspection of resistance (200μΩ±3%), appearance and lead continuity; Factory Test Report issued.
  2. Sampling Test: Per GB/T 2828.1-2012, sampling for withstand voltage, insulation and tensile strength, AQL=0.65.
  3. Acceptance Documents: Factory test report, material certificate, RoHS/REACH compliance (upon request).
 

7. Packaging & Transportation

 
  1. Packaging: Individually packed in anti‑static bags, 50/100 pcs per box. Outer box labeled with model, quantity, date and batch number.
  2. Transportation: Moisture‑proof and anti‑vibration packaging, avoid impact. Comply with RoHS and REACH for international logistics.

 

Core Functions

 
  • Flow Distribution / Collection: Distribute coolant from the main line evenly to multiple cold plates; collect heated fluid from each branch and return it to the cooling source / CDU after heat exchange.
  • Pressure & Resistance Management: Control pressure drop in each branch to prevent local overheating caused by uneven flow.
  • Simplified Piping & Maintenance: Reduce the number of connectors; with quick connectors, single cold plates can be rapidly installed or removed for maintenance.
  • Monitoring & Regulation (High‑end Models): Integrated flow meters, temperature / pressure sensors, and even valves for fine‑tuning flow in each branch.
 

Common Types & Structures

 

By Application

 
  • Manifold (Supply Side): 1 inlet, N outlets.
  • Collector (Return Side): N inlets, 1 outlet; usually used in pairs.
 

By Flow Division Method

 
  • Y‑type / Tee Manifold: 1 inlet, 2 outlets; suitable for small systems with two cold plates.
  • Bar / Row Manifold: 1 inlet, multiple outlets (e.g., 1‑to‑4, 1‑to‑6); commonly used in data centers / mining rigs.
  • Annular Manifold: For closed‑loop liquid cooling circuits.
 

By Adjustability

 
  • Fixed Type: No valves, low cost; flow determined by orifice / channel design.
  • Adjustable Type: Each branch equipped with needle / ball valves; flow adjustable manually or electrically.
 

Material & Interface

 
  • Materials: Mainly aluminum alloy / stainless steel / copper.
     
    Aluminum alloy: lightweight, moderate cost.
     
    Stainless steel: high pressure resistance, good corrosion resistance.
     
    Copper: excellent thermal conductivity but high cost.
     
    Must be compatible with system coolant to prevent corrosion.
  • Interfaces:
     
    PC water cooling: commonly G1/4" thread.
     
    Industrial / data center: flanges, compression fittings, quick connectors (e.g., DME, ISO 8434).
  • Sealing: Must use O‑rings / gaskets to prevent leakage; recommended materials: Nitrile Rubber (NBR) or Fluororubber (FKM).
 

Key Selection Parameters

 
  • Number of Branches & Flow Demand: Ensure sufficient flow for each cold plate to meet cooling requirements and avoid excessive pressure drop.
  • Working Pressure / Temperature: Industrial cold plates typically operate at 0.3–1 MPa, 30–50°C.
  • Flow Resistance & Uniformity: Flow channel design determines flow deviation; high‑end systems require inter‑branch flow deviation < 5%.
  • Interface Size & Compatibility: Match inner diameter of tubing and connector type.
  • Installation Space: Length and height of bar manifolds must fit cabinet / equipment layout.
 

Application Scenarios

 
  • Personal PC / Workstation: Y‑type manifold for CPU + GPU dual cold plates.
  • Data Center AI Servers: Rack‑mount bar manifolds, 1‑to‑8/16 for multi‑GPU cold plates.
  • Miner Clusters: Multi‑branch manifolds cooling multiple hash boards simultaneously.
  • New Energy Vehicle Battery Packs: Centralized supply and return for liquid cooling plates.
 

Installation & Notes

 
  • Separate supply and return lines to avoid thermal short‑circuit.
  • Tighten connectors evenly; torque wrench recommended.
  • Fully vent air during initial system filling.
  • Regularly inspect seal aging to prevent leakage.
  • Install manifold in an easily accessible and observable location.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    1,500,000-2,500,000

  • Employee Number:

    138~168

  • Ecer Certification:

    Verified Supplier

Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ... Uchi was established in 2006 in Dongguan, China.  After years of development, Uchi has become a large scale hi-tech enterprise that specialized in development and production of complete series of MOV,PTC, NTC series, PPTC series, Fuse(ALL TYPE),Resistor、integrated circuit 、 Capacitor, ...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Uchi Electronics Co.,Ltd
  • Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
  • https://www.uchidg.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement