Payment Terms | T/T, Western Union |
Delivery Time | 2-4 work days |
Packaging Details | Neutral Package |
Service | Outright sale |
Category | ultrasound calorie flow transducer |
Warranty | 1 year |
Description | healthcare solutions |
Purpose | use for patient |
Condition | compatible |
Brand Name | Siemens |
Model Number | VF10-5 |
View Detail Information
Explore similar products
PVT 375AT Toshiba Ultrasound Probes 2MHz for abdominal ultrasonic cleaning probe
Mindray 35C50HA Compatible Ultrasound Probe For General Imaging
Aloka UST 5299 Compatible Ultrasound Probe For Diagnosis Device
3.75 MHz Toshiba Ultrasound Probe , Convex Ultrasound Transducer PVM 375AT
Product Specification
Payment Terms | T/T, Western Union | Delivery Time | 2-4 work days |
Packaging Details | Neutral Package | Service | Outright sale |
Category | ultrasound calorie flow transducer | Warranty | 1 year |
Description | healthcare solutions | Purpose | use for patient |
Condition | compatible | Brand Name | Siemens |
Model Number | VF10-5 | ||
High Light | Siemens Linear Array Transducer ,Acuson VF10 5 Compatible Ultrasound Pr ,Acuson VF10 5 Linear Array Transducer |
Siemens Acuson VF10-5 Linear Array Transducer
1. Type:linear
2. Frequency:10-5MHz
3. Compatible system: Acuson Antares, Sonoline G40, Acuson X300
4. Application:Small parts, Peripheral Vascular, Cerebrovascular, Musculoskeletal
5. Condition: in good working condition
6. With 1 year warranty
Other Siemens compatible probes we can offer:
Brand | Model | Compatible System |
Siemens | 3.5C40H | Sonoline Elegra |
Siemens | 3.5C40S | SONOLINE Prima, SONOLINE Adara |
Siemens | 6.5EV13S | Prima / Adara |
Siemens | C5-2 | G50,G60, Omnia, Sienna,X300, |
Siemens | C5-2 | G20 |
Siemens | C6-2 | G50, G60, X500,X300,G60S |
Siemens | CH5-2 | G40, G60 S, X150, X300, X500 |
Siemens | CH6-2 | Antares |
Siemens | EC9-4 | G40,X300,X150,G50 |
Siemens | EC9-4 | G60,cv70 |
Siemens | EC9-4 | Antares |
Siemens | L10-5 | G50,X500,CV70,X300 |
Siemens | P4-2 | CV70,Sonoline G50, Sonoline G60, X500 |
Siemens | P4-2X | X300,G40,X150,Omnia |
Siemens | VF10-5 | G40, X300,X150 |
Siemens | VF10-5 | Antares |
Siemens | VF13-5 | G40, G50, X150, X300,G60 |
Siemens | VF13-5 | Antares |
Siemens | VF7-3 | Antares |
Knowledge point
Color Doppler flow imaging
Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.
Harmonic imaging
Harmonic imaging exploits non-linear propagation of ultrasound through the body tissues. When the frequency of emitted sound wave is f 0, the frequency of echo (due to reflection or scattering) includes f 0 (called fundamental wave), 2f 0, 3F 0 and so on The second harmonic (2f 0) has the largest energy.
Ultrasonic harmonic imaging (UHI) is based on the information of human body carried by the second harmonic in echo (reflection or scattering). Harmonic imaging without UCA is called native harmonic imaging or tissue harmonic imaging. Harmonic imaging using UCA (ultrasound contrast agent) is called contrast harmonic imaging.
Multi-frequency probe
Multi-frequency probe is a new development of pulse-echo transducer. The probe can send out several different ultrasonic pulses, so as to cover the near field with high-frequency ultrasound, the intermediate-frequency ultrasound to cover the transition zone between the far and near fields, and the low-frequency ultrasound to cover the far field. The unit multi-frequency probe is to bond multiple layers of piezoelectric ceramics (or polymer piezoelectric materials) to each other, and lead wires from the electrodes between each layer to obtain multiple frequency ultrasonic pulse emission through exciting different layers . The digital coding of the multi-frequency probe is simple but easy to lose the signal.
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Verified Supplier
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!