Payment Terms | T/T,Western Union |
Delivery Time | 2-4 work days |
Packaging Details | Neutral Package |
Category | laparoscopy instruments |
Description | certified refurbished echo ultrasound |
System | troubleshooting ultrasound device |
Warranty | 60 days after fixed |
Condition | Siemens X150 used medical device |
Purpose | medical repair engineer team |
Brand Name | Siemens |
Model Number | Siemens X150 |
View Detail Information
Explore similar products
Preirus Troubleshoot Ultrasound Machine Repair Hitachi Aloka
S2000 Color Doppler Medical Machine Repair For Startup Failure
GE Clinic Ultrasound Machine Repair
EPIQ 7 Ultrasound Machine Repair
Product Specification
Payment Terms | T/T,Western Union | Delivery Time | 2-4 work days |
Packaging Details | Neutral Package | Category | laparoscopy instruments |
Description | certified refurbished echo ultrasound | System | troubleshooting ultrasound device |
Warranty | 60 days after fixed | Condition | Siemens X150 used medical device |
Purpose | medical repair engineer team | Brand Name | Siemens |
Model Number | Siemens X150 | ||
High Light | Simens X150 Ultrasound Machine Repair ,Laparoscopy Ultrasound Machine Repair |
Siemens ventilator has internal alarm system test function, technical error should be the test alarm system failure prompt. There are three reasons for this failure:
The first is the failure of the system software;
The second is the device behind the speaker failure;
The third is the PC1777 circuit board hardware failure.
After the boot into the maintenance engineer software status, the use of software is proofread, found that the latest version of the system software is running normally, and then the loudspeaker test, show that its working parameters are not normal.
Apart the speaker will be removed after breathing machine screen, measured with a multimeter and found that the parts have been damaged, intends to replace the original speaker, but the factory price is very expensive, according to the measured parameters, found that a speaker can completely replace the electronics market performance, be replaced after purchase, installed the screen restart, not the technical errors now red alarm, The fault is removed.
Repair List of Featured Ultrasonic Board & Assy | |||
Brand | System | Description | Part Number |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P6 | CPU mainboard | |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |
Aloka | Alpha 5 | mainboard | EP493700DD |
Aloka | Alpha 6 | RX Beam Former | EP555501AA |
Aloka | Alpha 6 | CW board | EP555700 |
Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
Aloka | Alpha 6 | TX/RX | EP555300 |
Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
Aloka | Alpha 10 | RX Beamformer board | EP531800CE |
Aloka | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | mainboard | EP575700BC/EP560800 |
Aloka | F75 | USP board | EP556600 |
Aloka | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Ascendus | CELL | 7352830A |
Siemens | X150/G40 | BE | 10131804 |
Siemens | X300 | BE 2.0/BE 3.0/BE 7.5 | 10131990 |
Siemens | X700 | BE | 10136465 |
Siemens | X700 | RC | 10136467 |
Siemens | X700 | TI | 11014292 |
Siemens | Antares | BE | 7472421 |
Siemens | Antares | CB | 7288504 |
Siemens | S2000 | RM300 | 10852163 |
Siemens | S2000 high version/S3000 | RM301 | 10854749 |
iU22/iE33 | EMB excelsior motherboard | 453561419431/453561382231/453561419431 | |
iU22/iE33 | UMB Unified Motherboard | 453561254492/453561360251 | |
HD15 | ACB acquisition control board | 453561197145/453561197144 | |
HD15 | AIM board | 4.53561E+11 | |
CX50 | control panel | 4.53562E+11 | |
CX50 | mainboard | 453561368033/453561622163/453561495832 | |
Affiniti 70 | ACQ acquisition control board | ||
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561734844/453561704246 | |
Biosound | Mylab Series | CPU mainboard | 9501361000 |
Toshiba | Aplio 300/400/500 | mainboard | PM30-38696 |
Toshiba | Aplio 500 | RX | ywm2056*a |
Toshiba | Xario 200 | TX | PM30-32732-1 |
Toshiba | Xario 200 | RX | PM30-32733-1 |
Remarks | |||
1.The repair cycle is within 3-5 days. | |||
2.Warranty after fixed:60 days. | |||
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge. | |||
4.Package price is available if repair 3 pcs or more at one time. | |||
5.Extra discount for VIP partners. | |||
6.You could have different part No.under same description. |
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2014
Total Annual:
5,000,000-10,000,000
Employee Number:
50~60
Ecer Certification:
Active Member
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...
Get in touch with us
Leave a Message, we will call you back quickly!