Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"IO Board 5433408-12 GE LOGIQ E9 for Ultrasound System Repair\/Sell","imgUrl":"https:\/\/img.chinax.com\/nimg\/25\/9f\/6c0e4bbdef6923f8f85dd36c91b2-200x200-1\/io_board_5433408_12_ge_logiq_e9_for_ultrasound_system_repair_2fsell.jpg","attrs":{"Brand Name":"GE","Model Number":"5433408-12","Minimum Order Quantity":"1","Price":"Negotiable"}}
{"title":"Ultrasonic Board CX50 Control Board Imaging Device sonic cleaning machine","imgUrl":"https:\/\/img.chinax.com\/nimg\/c8\/38\/d32b8e8e839c909e8748ebb395fd-200x200-1\/ultrasonic_board_cx50_control_board_imaging_device_sonic_cleaning_machine_453561685791_for_philips.jpg","attrs":{"Brand Name":"philips","Model Number":"453561210241","Price":"Negotiable","Payment Terms":"T\/T,Western Union"}}
{"title":"Ultrasonic Board Siemens X300 BE Board (P\/N:10348317)\/Ultrasound Point Of Care","imgUrl":"https:\/\/img.chinax.com\/nimg\/f9\/c6\/babde6b49018bcf2f6fca5fb4058-200x200-1\/ultrasonic_board_siemens_x300_be_board_28p_2fn_3a10348317_29_2fultrasound_point_of_care.jpg","attrs":{"Brand Name":"Siemens","Model Number":"10348317","Price":"Negotiable","Payment Terms":"T\/T,Western Union"}}
1.Part number: 5433408-12 2.Pre-owned original one ,in excellent condition 3.We provide 60 days warranty
Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison ultrasonic boards are within our repair/ maintenance range.
Other ultrasound parts related to GE that we can offer:
Knowledge Point
GE LOGIQ E9 IO Board 5433408-12
1. Basic Information
Name: GE LOGIQ E9 IO Board (spare part number: 5433408-12)
Equipment: GE LOGIQ E9 Ultrasound Diagnostic Instrument
Function: IO Board (input and output board) is a key component in the ultrasound diagnostic instrument, responsible for signal transmission and communication between the internal equipment and external equipment (such as probes, displays, keyboards, etc.). In GE LOGIQ E9, IO Board may carry important tasks such as receiving ultrasound signals from the probe, sending image data to the display, and processing control commands entered by users through the keyboard and mouse.
2. Functions and Roles
Signal Transmission: IO Board acts as a bridge between the internal and external equipment of the device to ensure accurate and fast transmission of information such as ultrasound signals, image data, and control commands.
Equipment Communication: It may also be responsible for communication with other internal boards (such as processing boards, power boards, etc.) to ensure the coordinated operation of the entire ultrasound diagnostic instrument system.
Performance Guarantee: The performance of IO Board directly affects the image quality, response speed, and overall stability of the ultrasound diagnostic instrument.
3. Possible faults and solutions Although it is impossible to directly give specific fault phenomena and solutions for the IO Board with spare part number 5433408-12, based on the general maintenance experience of ultrasonic diagnostic instruments, the following are some possible fault phenomena and general solutions:
No image display or abnormal image: There may be a problem with the connection between the IO Board and the display or probe. At this time, you can check whether the connection cable is plugged in tightly and whether it is damaged, and try to re-plug the connection cable. If the problem persists, you may need to replace the IO Board or related components.
The device cannot recognize the probe: There may be a fault in the probe interface on the IO Board. You can try to replace the probe to eliminate the problem of the probe itself. If the problem persists, you need to consider replacing the IO Board.
System freeze or restart: In some cases, the failure of the IO Board may cause the system to freeze or restart frequently. This may be caused by damage to the circuit components on the IO Board or software conflicts. At this time, you can try to restart the device to resume normal operation. If the problem cannot be solved, you need to contact professional maintenance personnel for troubleshooting and repair.
We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.
If you need any product, please feel free to contact us.
Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex... Rongtao Medical was established in 2013, we have been focusing on providing after-sales service for medical equipment for the last ten years, especially in ultrasound. We have been continuously improving our technical capabilities, breaking through technical problems, innovating service models to ex...