China factories

Chat Now Send Email
China factory - Henan Hongtai HVAC Equipment Co., Ltd.

Henan Hongtai HVAC Equipment Co., Ltd.

  • China,Zhengzhou ,Henan
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Wall Mounted VRF Unit CE Certified Gold Fin Residential Commercial HVAC The Wall
China Wall Mounted VRF Unit CE Certified Gold Fin Residential Commercial HVAC The Wall

  1. China Wall Mounted VRF Unit CE Certified Gold Fin Residential Commercial HVAC The Wall
  2. China Wall Mounted VRF Unit CE Certified Gold Fin Residential Commercial HVAC The Wall

Wall Mounted VRF Unit CE Certified Gold Fin Residential Commercial HVAC The Wall

  1. MOQ:
  2. Price:
  3. Get Latest Price
Optional Pump Head 1,200 mm
Minimum Sound Level 27 dB(A)
Refrigerant R32 low GWP (GWP 675, F-Gas compliant)
Capacity Range 2.2–7.1 kW
Bus Communication HyperLink, up to 2,000 m
Product Name Wall Mounted
Power Supply Independent supply (partial shutdown tolerant)
Certification CB, ISO
Place of Origin China
Brand Name OEM; MIDEA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Optional Pump Head 1,200 mm Minimum Sound Level 27 dB(A)
Refrigerant R32 low GWP (GWP 675, F-Gas compliant) Capacity Range 2.2–7.1 kW
Bus Communication HyperLink, up to 2,000 m Product Name Wall Mounted
Power Supply Independent supply (partial shutdown tolerant) Certification CB, ISO
Place of Origin China Brand Name OEM; MIDEA
High Light Wall Mounted VRF Unit CE CertifiedResidential Commercial HVAC unitDC Inverter VRF with warranty
Wall Mounted VRF Unit - CE Certified Gold Fin Residential Commercial HVAC
The wall-mounted unit that installs like a ducted system and looks like one, featuring 30mm top-flush mounting, 27 dB(A) sound floor, and triple-vector drainage to eliminate traditional wall-mounted compromises.
Product Overview
Wall-mounted units have historically been the "last resort" option—chosen when ceiling access is impossible and aesthetics are sacrificed for functionality. The Midea V8 Wall Mounted overturns that assumption entirely. A re-engineered heat exchanger geometry enables top-flush mounting with just 30 mm clearance from the ceiling—eliminating the unsightly gap that collects dust and undermines the room's visual continuity. The result is a wall-mounted unit that looks as intentional and integrated as a concealed ducted installation.
At 27 dB(A) minimum sound level, the unit operates below the ambient noise floor of most residential and hospitality environments—making it virtually inaudible during sleeping hours. The bidirectional Coanda effect intelligently routes air: ceiling-hugging in cooling mode to prevent cold downdrafts, and wall-following in heating mode to deliver warmth to floor level where occupants actually feel it. Combined with mmWave occupancy sensing and unrestricted drainage routing (horizontal, downward, or upward—plus optional pumped lift), this is the wall-mounted unit that designers no longer need to apologize for specifying.
As part of the V8 heat pump VRF platform, the Wall Mounted provides all-season climate control through reverse-cycle cooling and heating. Individual zone control lets each room maintain its own setpoint independently—critical for hotel VRF solutions where guest room climate control must balance comfort with energy conservation. The DC inverter compressor's variable speed operation delivers energy saving up to 40% versus conventional systems.
Core Features & Benefits
27 dB(A) Ultra-Quiet Operation
At minimum fan speed, the unit produces just 27 decibels—quieter than a whisper in a library. This acoustic benchmark makes it ideal for sleeping quarters, patient rooms, and environments where HVAC noise impacts occupant satisfaction.
30mm Top-Flush Mounting
Redesigned thermal exchange geometry eliminates the traditional 100+ mm gap between the unit top and ceiling. With only 30 mm clearance required, the unit sits visually flush against the ceiling plane—eradicating dust-collecting ledges and creating clean architectural lines.
Bidirectional Coanda Air Routing
In cooling mode, the Coanda effect adheres the air jet to the ceiling surface, preventing cold drafts from descending into occupied zones. In heating mode, the warm air stream follows the wall surface downward, naturally delivering heat to floor level where human thermal comfort is most sensitive.
mmWave Occupancy-Aware Operation
Integrated radar module detects room vacancy and autonomously transitions to energy-reduction mode; re-entry triggers immediate return to active comfort. This demand-driven approach is valuable in hotel VRF solutions and patient rooms where occupancy is intermittent.
Three-Axis 3D Air Distribution
Simultaneous automatic vertical and horizontal louver actuation creates a three-dimensional air pattern that sweeps conditioned air throughout the room volume—eliminating stagnant pockets and thermal stratification.
Unrestricted Drainage Routing
Unlike conventional wall-mounted units limited to gravity-only drainage, the V8 Wall Mounted supports horizontal, downward, and upward drain paths—plus an optional 1,200 mm high-lift pump. This eliminates major installation constraints in complex building layouts.
Fully Enclosed Acoustic Architecture
Internal components and optional pump adopt sealed enclosures that prevent sound transmission through the unit casing—directly contributing to the 27 dB(A) performance and ensuring consistent acoustic performance.
Dedicated Sleep Protocol
Sleep mode gradually modifies temperature setpoint and fan speed throughout the night cycle—optimizing thermal comfort and energy conservation during hours when occupants cannot adjust settings.
Application Scenarios
Scenario Description
Hotel Guest Rooms 27 dB(A) preserves sleep quality; 30mm flush mount eliminates visual compromise; hotel VRF solution at its most guest-friendly
Premium Residential Suites Residential-grade aesthetics with commercial VRF efficiency and centralized controllability
Hospital Patient Rooms Ultra-low sound supports recovery protocols; occupancy radar automates unoccupied setbacks; hospital VRF system integration
Senior Living Quarters Intuitive wall-level controls; Coanda heating delivers warmth at floor level for elderly comfort
Boutique Office Suites Clean visual lines without duct infrastructure; flexible drainage adapts to partition layouts; office building VRF versatility
School Dormitories Reliable, quiet operation for student accommodation; campus air conditioning with individual room control
Certifications & Standards
• CE Certified – Full European conformity, R32 low GWP refrigerant (GWP 675), F-Gas compliant
• Eurovent – Certified performance data for European market compliance
• TÜV SÜD – Third-party verified safety and performance standards
• SASO Certified – Saudi Arabian standards approval
• ESMA Approved – UAE standardization compliance
• GCC Standard Compliant – Gulf region deployment ready
• ISO 9001 – Quality management ensuring consistent manufacturing quality
• ISO 14001 – Environmental management system for responsible production
• ISO 45001 – Occupational health and safety standards across the product lifecycle
Technical Specifications
Parameter Wall Mounted
Capacity Range 2.2-7.1 kW
Minimum Sound Level 27 dB(A)
Top-Flush Clearance 30 mm minimum
Air Distribution 3D (auto vertical + horizontal sweep)
Coanda Routing Bidirectional (cooling-to-ceiling / heating-to-wall)
Occupancy Radar mmWave (auto setback)
Drainage Paths Horizontal / downward / upward (unrestricted)
Optional Pump Head 1,200 mm
Acoustic Design Fully enclosed architecture
Sleep Protocol Supported
Pump Fault Feedback Supported
Bus Communication HyperLink, up to 2,000 m
Power Architecture Independent supply (partial shutdown tolerant)
Refrigerant R32 low GWP (GWP 675, F-Gas compliant)
System Compatibility Heat pump VRF / Heat recovery VRF
BMS Integration Modbus RTU / BACnet compatible
System Compatibility
Compatible with all V8 series outdoor units via HyperLink arbitrary topology communication. Full BMS integration via Modbus RTU and BACnet protocols.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2023

  • Total Annual:

    6,000,000-8,000,000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Henan Hongtai HVAC Equipment Co., Ltd. is a technology-based service enterprise integrating the sales of air-conditioning system and related accessories, exporting the products with good quality and the most suitable ones for customers' project. Our main products include VRF system, Chille... Henan Hongtai HVAC Equipment Co., Ltd. is a technology-based service enterprise integrating the sales of air-conditioning system and related accessories, exporting the products with good quality and the most suitable ones for customers' project. Our main products include VRF system, Chille...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Hongtai HVAC Equipment Co., Ltd.
  • NO. 1406, 14TH FLOOR, BUILDING 3, NO. 50, CHUANGFU XINCHENG, JINGGUANG ROAD STREET, ERQI DISTRICT, ZHENGZHOU CITY, HENAN PROVINCE, CHINA
  • https://www.unit-hvac.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement