| Payment Terms | T/T | 
| Supply Ability | 10-100000 | 
| Delivery Time | 3~7Day | 
| Operating Mode | Automatic And Manual Working Modes Are Available | 
| Pump Protection | Protection Functions Such As Overload, No Load, And Ultra Low Voltage | 
| Control Distance: | The Longest Control Distance Is 500 Meters | 
| Signal: | AC Digital Signal Detection Function, | 
| power | 0.4KW~15KW | 
| memory | Fault memory function, 5 reasons for failure can be found | 
| Brand Name | Kinda | 
| Model Number | PC | 
| Place of Origin | China | 
View Detail Information
Explore similar products
 
                            Easy Operation Water Pump Controller 220/380V Self - Contained Overload
 
                            Self Contained Water Pump Controller 500m Control Distances Ultra Low Pressure
 
                            Durable Automatic Water Tank Pump Controller Adopts Digital Core With Overload
 
                            3 Phase Automatic Water Pump Controller 380V 0.4-15KW 500 Meters Control
Product Specification
| Payment Terms | T/T | Supply Ability | 10-100000 | 
| Delivery Time | 3~7Day | Operating Mode | Automatic And Manual Working Modes Are Available | 
| Pump Protection | Protection Functions Such As Overload, No Load, And Ultra Low Voltage | Control Distance: | The Longest Control Distance Is 500 Meters | 
| Signal: | AC Digital Signal Detection Function, | power | 0.4KW~15KW | 
| memory | Fault memory function, 5 reasons for failure can be found | Brand Name | Kinda | 
| Model Number | PC | Place of Origin | China | 
| High Light | automatic water level controller ,water pump pressure controller | ||
Self-contained automatic pump controller with no-load protection
The automatic pump controller is simple and efficient. When the pump is started to pump water, it is often forgotten to shut it down, resulting in waste of electricity and water. The installation of the fully automatic pump is simple and efficient to solve the start and stop of the pump. When the pool is filled with high water level, the pump water supply is stopped by the sensor signal. When the pool is at low water level, the sensor signal starts the pump to pump water.
 
 The automatic water pump controller adopts digital core with overload, no load and ultra low voltage protection. The upper and lower levels and pressure are automatically controlled in one.
Can be connected to float control, pressure gauge control and probe sensor control
Selection Guide
| Inverter Model | Suitable motor | Pump quantity | Breaker | 
| Single phase 220V | |||
| PC1-S2-1500 | 0.37~1.5kW | 1 | No | 
| PC1-S2-2200 | 0.37~2.2kW | 1 | No | 
| PC2-S2-2200B | 0.37~2.2kW | 2 | Build-in | 
| Three phase 220V | |||
| PC1-T2-2200 | 0.37~2.2kW | 1 | No | 
| PC1-T2-2200B | 0.37~2.2kW | 1 | Build-in | 
| PC2-T2-2200B | 0.37~2.2kW | 2 | Build-in | 
| PC1-T2-4000 | 1.0~4.0kW | 1 | No | 
| PC1-T2-4000B | 1.0~4.0kW | 1 | Build-in | 
| PC2-T2-4000B | 1.0~4.0kW | 2 | Build-in | 
| PC1-T2-7500B | 1.0~7.5kW | 1 | Build-in | 
| PC2-T2-7500B | 1.0~7.5kW | 2 | Build-in | 
| Three phase 380V | |||
| PC1-T4-2200 | 0.37~2.2kW | 1 | No | 
| PC1-T4-2200B | 0.37~2.2kW | 1 | Build-in | 
| PC2-T4-2200B | 0.37~2.2kW | 2 | Build-in | 
| PC1-T4-4000 | 1.0~4.0kW | 1 | No | 
| PC1-T4-4000B | 1.0~4.0kW | 1 | Build-in | 
| PC2-T4-4000B | 1.0~4.0kW | 2 | Build-in | 
| PC1-T4-7500 | 1.0~7.5kW | 1 | No | 
| PC1-T4-7500B | 1.0~7.5kW | 1 | Build-in | 
| PC2-T4-7500B | 1.0~7.5kW | 2 | Build-in | 
| PC1-T4-11000B | 2.2~11kW | 1 | Build-in | 
| PC2-T4-11000B | 2.2~11kW | 2 | Build-in | 
| PC1-T4-15000B | 2.2~15kW | 1 | Build-in | 
| PC2-T4-15000B | 2.2~15kW | 2 | Build-in | 
Technical Specifications
| Item | Technical Index | Specification | 
| Input | Input voltage | 1AC 220V±15%, | 
| 3AC 220V±15% | ||
| 3AC 380V±15% | ||
| Input frequency | 50/60Hz±5% | |
| Self-consumed power | Standby state | <3.5W | 
| Running state | <4.5W | |
| Default setting | No-load current | 0.0A | 
| No-load restart time | 30 minutes | |
| Control distance | Maximum control distances | 500m | 
| Overload protection time | Inverse time limit (±15% time error | 120% / 50s | 
| 150% / 30s | ||
| 200% / 15s | ||
| 300% / 6s | ||
| 500% / 1s | 
Description of wiring connection and parameters setting area
1.Build-in the main circuit breaker

2.Without the main circuit breaker

Company Details
Business Type:
Manufacturer 
Year Established:
2012 
Total Annual:
12000000.00-15000000.00
Employee Number:
300~500 
Ecer Certification:
Active Member 
Shenzhen Kinda Technology Co., Ltd., established in 2012, is a technology innovation enterprise. Specializing in the production of export servo drive inverters permanent magnet synchronous motors, integrating product design, development and production. Our company is located in the urban area of ... Shenzhen Kinda Technology Co., Ltd., established in 2012, is a technology innovation enterprise. Specializing in the production of export servo drive inverters permanent magnet synchronous motors, integrating product design, development and production. Our company is located in the urban area of ...
Get in touch with us
Leave a Message, we will call you back quickly!