| Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production |
| AC Recovery Strategy | High - Power Generator or Utility Recharge |
| Solar Design Approach | Larger PV Input for Daily Energy Recovery |
| Remote Site Profile | Cabin / Remote Office / Communication Station |
| Supply Ability | 5000 Units per Month |
| Operating Boundary | Integrated Source for Selected Loads, Not Whole - Site Power |
| Off - Grid Capacity Tier | Extended Essential-Load Energy System |
| Payment Terms | L/C,T/T,Western Union |
| System Portability | Relocatable without Permanent Electrical Cabinet |
| Load Control Level | Scheduled Medium - Power Equipment |
| Backup Reserve Method | Separate Daily Use from Emergency Capacity |
| Packaging Details | Heavy-Duty Wooden Case with Protective Foam |
| Certification | MSDS , UN38.3 |
| Model Number | PS-2KWH-1KW-US-A-2 |
| Brand Name | Voltertech |
| Place of Origin | China |
View Detail Information
Explore similar products
1000W 2009Wh Portable Off Grid Energy Storage System With MPPT Solar Charging
1kWh LiFePO4 Off Grid Energy Storage With 300W PV 500W AC Charging
61kWh 12kW Stacked Off Grid Energy Storage System 10kW PV Array Microgrid Hub
15.36kWh 12kW Off Grid Energy Storage System With Pure Sine Wave Output
Product Specification
| Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production | AC Recovery Strategy | High - Power Generator or Utility Recharge |
| Solar Design Approach | Larger PV Input for Daily Energy Recovery | Remote Site Profile | Cabin / Remote Office / Communication Station |
| Supply Ability | 5000 Units per Month | Operating Boundary | Integrated Source for Selected Loads, Not Whole - Site Power |
| Off - Grid Capacity Tier | Extended Essential-Load Energy System | Payment Terms | L/C,T/T,Western Union |
| System Portability | Relocatable without Permanent Electrical Cabinet | Load Control Level | Scheduled Medium - Power Equipment |
| Backup Reserve Method | Separate Daily Use from Emergency Capacity | Packaging Details | Heavy-Duty Wooden Case with Protective Foam |
| Certification | MSDS , UN38.3 | Model Number | PS-2KWH-1KW-US-A-2 |
| Brand Name | Voltertech | Place of Origin | China |
| High Light | 2kWh Off Grid Energy Storage System ,UN38.3 Off Grid Energy Storage System ,550W Off Grid Solar Storage | ||
2kWh Off Grid Energy Storage System with 550W Solar and 1000W AC Charging
This 2kWh off-grid energy storage system combines a 2000Wh LiFePO4 battery, 1000W pure sine wave inverter, 550W solar charging input and 1000W AC charging capability. It is designed for selected loads at cabins, remote offices, temporary work locations and communication sites.
A reliable off-grid plan starts with a full 24-hour load schedule. Record when each device operates, how much power it uses and whether it must remain available during poor weather or generator downtime.
The 2000Wh rating is nominal battery energy. The amount delivered to AC loads is affected by inverter efficiency, station consumption, temperature and the reserve maintained for critical equipment.
Base Load
Include routers, security systems, lighting and communication devices that run for long periods.
Scheduled Work Load
Laptops, monitors and selected equipment can be assigned to periods when solar charging is strongest.
Restricted Load
High-consumption appliances should be limited when preserving energy for essential operation is more important.
The PV input supports 12–60V and up to 550W. Solar-array voltage must remain within this range at both normal operating voltage and maximum open-circuit voltage.
The required solar capacity depends on how much energy is used each day and the number of effective sunlight hours. Weather losses, panel temperature, shading and conversion efficiency should be included.
When daily energy use approaches the battery capacity, the solar source must provide enough surplus energy to operate daytime loads and recharge the battery.
The station supports up to 1000W AC charging from a compatible 85–135Vac, 60Hz source. This can reduce recovery time when solar conditions are poor or when the system must be prepared quickly for the next operating period.
When a generator is used, its voltage, frequency and available continuous power must remain stable enough for the charging input. Other generator loads should be included in the capacity calculation.
The pure sine wave inverter supplies a rated 1000W AC output at 110Vac and 60Hz. This supports a wider range of compatible loads than lower-output stations, but combined equipment must remain within the rating.
No separate surge-output value is listed in the source specification. Pumps, compressors and motor-driven equipment should therefore be reviewed before inclusion in the off-grid load plan.
USB and PD 20W Type-C ports provide direct charging for compatible electronics and may reduce the need to operate AC adapters.
This unit integrates the battery, inverter and charging functions. Solar panels, generator, external extension wiring and site-specific protection are separate items.
The station weighs 18.5kg net and can be relocated when required, but it should be placed on a stable surface with protected airflow and cable access.
No exposed-outdoor rating is stated. Install the system in a dry, covered and ventilated location away from rain and condensation.
| Off-Grid Storage Capacity | 2000Wh LiFePO4 Battery |
| AC Supply Rating | 1000W / 110Vac ±5Vac / 60Hz ±0.5% |
| AC Output Waveform | Pure Sine Wave |
| Solar Charging Capacity | 12–60V / 550W Maximum |
| AC or Generator Charging | 85–135Vac / 60Hz / 1000W |
| Low-Voltage Device Ports | 2 × USB 2.0 / Type-C PD 20W |
| Source Transfer Time | Less Than 50ms |
| Physical System Data | 280 × 230 × 285mm / 18.5kg Net / 20.1kg Gross |
| Working Environment | -10°C to 40°C / 20–95% RH / Noise Below 50dB |
It integrates battery, inverter and charging functions, but solar panels and site wiring are selected separately.
That depends on simultaneous power, daily energy use and whether high-consumption loads are restricted.
The generator must provide compatible voltage, frequency and sufficient stable power after its other loads are considered.
The equipment’s startup demand must be confirmed because no separate inverter surge rating is stated.
Provide the 24-hour load schedule, peak power, solar conditions, generator data and required backup reserve.
Need to evaluate solar recovery and selected remote-site loads?
Company Details
Business Type:
Manufacturer
Year Established:
15 Years
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
/* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width... /* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width...
Get in touch with us
Leave a Message, we will call you back quickly!