| Battery-Side Architecture | 1000–1500V High-Voltage DC |
| Control Integration | Battery & Dispatch Communication |
| Supply Ability | 5000 Units per Month |
| System Function | MW-Class Energy Storage Power Conversion |
| Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production |
| Installation Format | Containerized Power Equipment |
| Payment Terms | L/C,T/T,Western Union |
| Electrical Position | AC-Side Conversion & Grid Interface |
| Isolation Design | Transformer-Isolated |
| Grid Connection Class | 10kV Medium-Voltage Interface |
| Project Buyer | EPC / System Integrator / Energy Contractor |
| Packaging Details | Heavy-Duty Wooden Case with Protective Foam |
| Place of Origin | China |
| Model Number | BESS-25MW-W |
| Certification | IEC62477-1 , IEC61000-6/2/4 , UN3536 |
| Brand Name | Voltertech |
View Detail Information
Explore similar products
233kWh Liquid Cooled Commercial Battery Energy Storage Cabinet with LiFePO4
12kW 64kWh Rack Mount Commercial Energy Storage System With Dual MPPT
200kWh 640V Rack Mount LiFePO4 Battery 314Ah Utility Storage Titan
3.72MWh 1331.2V Containerized Commercial Battery Energy Storage System With
Product Specification
| Battery-Side Architecture | 1000–1500V High-Voltage DC | Control Integration | Battery & Dispatch Communication |
| Supply Ability | 5000 Units per Month | System Function | MW-Class Energy Storage Power Conversion |
| Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production | Installation Format | Containerized Power Equipment |
| Payment Terms | L/C,T/T,Western Union | Electrical Position | AC-Side Conversion & Grid Interface |
| Isolation Design | Transformer-Isolated | Grid Connection Class | 10kV Medium-Voltage Interface |
| Project Buyer | EPC / System Integrator / Energy Contractor | Packaging Details | Heavy-Duty Wooden Case with Protective Foam |
| Place of Origin | China | Model Number | BESS-25MW-W |
| Certification | IEC62477-1 , IEC61000-6/2/4 , UN3536 | Brand Name | Voltertech |
| High Light | 2.5MW Energy Storage Power Conversion System ,10kV Containerized Energy Storage System ,Transformer-Isolated Power Conversion Unit | ||
2.5MW 10kV Containerized Energy Storage Power Conversion System.
This containerized power conversion unit provides 2500kW rated DC-side power across a 1000–1500V operating voltage range and a 2500kVA AC-side interface rated at 10kV. Transformer isolation, battery communication and dispatch communication interfaces are specified for integration within an energy storage project.
For a MW-class energy storage project, selecting the power conversion equipment begins with electrical compatibility rather than battery energy capacity alone. The battery-side DC voltage, required conversion power and AC grid interface all need to match the project architecture.
The DC side is rated at 2500kW with a maximum current of 2619A. On the AC side, rated output power is specified at 2500kVA with a rated voltage of 10kV.
The specified AC-side power factor is adjustable from -1 to +1, while maximum total harmonic distortion is listed as no more than 3% at rated power.
Swipe left or right to view the full specification table.
| Section | Parameter | Specification |
|---|---|---|
| DC Side | Operating Voltage Range | 1000–1500V |
| DC Side | Rated Output Power | 2500kW |
| DC Side | Maximum Current | 2619A |
| AC Side | Rated Output Power | 2500kVA |
| AC Side | Rated AC Voltage | 10kV |
| AC Side | Rated AC Current | 145A |
| AC Side | Isolation Mode | Transformer Isolation |
| AC Side | Total Harmonic Distortion | ≤3% at Rated Power |
| AC Side | Power Factor | -1 to +1 Adjustable |
| System | Cooling Mode | Air Cooling |
| System | Operating Temperature | -25°C to +50°C |
| System | Storage Temperature | -25°C to +55°C |
| System | Operating Relative Humidity | 0% – 95% |
| System | Working Altitude | ≤2000m |
| System | Dimensions | 5523 × 2400 × 2800mm |
| System | Net Weight | Approx. 15T |
The specification separates battery-side communication from dispatch communication, allowing the power conversion unit to exchange information with compatible battery equipment and project-level control systems.
Electrical compatibility is only one part of project selection. The physical container measures 5523 × 2400 × 2800mm and has an approximate net weight of 15 tonnes.
These values should be considered when planning the available installation area and equipment handling requirements. The specified operating temperature range is -25°C to +50°C, with a working altitude of up to 2000m.
Air cooling is specified as the cooling method for this configuration. Although the source document carries a general liquid-cooling product heading, the individual technical parameter for this model explicitly lists air cooling.
Suitability depends on the required conversion power, battery-side DC voltage and AC grid connection. This configuration is rated at 2500kW on the DC side, operates within a 1000–1500V DC range and provides a 10kV AC interface. These values should be checked against the electrical architecture of the project.
The AC side is specified at 2500kVA with a rated voltage of 10kV and transformer isolation. Final connection design should still be confirmed according to the project's grid requirements and electrical design.
The specified DC operating voltage range is 1000V to 1500V, with a maximum DC current of 2619A. The battery system should be configured so that its operating voltage remains within these limits.
The technical parameter sheet does not specify a fixed battery capacity in kWh or MWh. This product is defined by its power conversion, DC input and 10kV AC-side parameters, so the battery configuration should be confirmed separately according to the project requirements.
Yes. Dispatch communication interfaces include Modbus RTU, Modbus TCP and IEC 60870-5-104. Battery-side communication interfaces include CAN and RS485. Final compatibility should be checked against the project's control platform.
The main difference is rated power capacity. The appropriate configuration should be selected according to the project's required power, battery DC architecture, 10kV AC-side requirements, installation space and overall system design rather than choosing by power rating alone.
The equipment dimensions are 5523 × 2400 × 2800mm with an approximate net weight of 15 tonnes. The specified operating temperature range is -25°C to +50°C and the working altitude is up to 2000m. These values should be considered during site planning.
Provide the required system power, battery-side DC voltage range, AC grid voltage, communication requirements, site temperature, altitude and available installation space. If the battery system has already been selected, its DC voltage and current information should also be provided for compatibility checking.
Provide your required power, battery-side DC voltage, AC grid voltage, communication requirements and site conditions. The 2.5MW / 10kV configuration can then be evaluated against your project parameters.
Discuss Your 2.5MW Energy Storage ProjectCompany Details
Business Type:
Manufacturer
Year Established:
15 Years
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
/* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width... /* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width...
Get in touch with us
Leave a Message, we will call you back quickly!