China ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU
China ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU

  1. China ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU
  2. China ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU

ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU

  1. MOQ: 100pcs
  2. Price: $180
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T
Supply Ability 100000pcs/month
Delivery Time 35 work days after receipt of the deposit
Packaging Details Standard export carton box package suitable for container shipment.
Panel Design QA
EER 2.5~3.5
Logo Oem or Yuetu
Name Wall Mounted Air Cond
Paytmen term TT/LC/OA
Factory Certification ISO
Brand Name YUETU or OEM
Model Number 18000BTU
Certification CE/BC
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T Supply Ability 100000pcs/month
Delivery Time 35 work days after receipt of the deposit Packaging Details Standard export carton box package suitable for container shipment.
Panel Design QA EER 2.5~3.5
Logo Oem or Yuetu Name Wall Mounted Air Cond
Paytmen term TT/LC/OA Factory Certification ISO
Brand Name YUETU or OEM Model Number 18000BTU
Certification CE/BC Place of Origin CHINA
High Light 48GW Wall Mounted Air Cond18000BTU Wall Mounted Air Cond1300RPM R32 Wall Mounted ac

ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU

 

QA Panel 50HZ 220V R410a/R32 18000BTU Cooling Heating High Quality Wifi Control PCB 3 Year Warranty

 

      18000BTU
Model No. TAC-18CHS/Z
  KFR-48GW
  indoor860(Φ7×2)+outdoor820(Φ7.94×2)
Type Heating Pump
Control type  
Rated cooling capacity Btu/h;W 15695;4600
Rated heating capacity Btu/h;W 17674;5180
EER for cooling Btu/h.w; W/W 2.4
COP for heating W/W 2.64
Moisture removal Liters/h 1.99
Pressure High(DP) MPa 2.6
Low(SP) MPa 1
Indoor noise level at cooling High dB(A) 42
Med. dB(A) 39
Low dB(A) 36
Outdoor noise level dB(A) 58
       
Power supply  
Voltage Range V 198~242
Rated current Cooling A 9.8
Heating A 9.5
Rated input Cooling W 2042
Heating W 1958
Annual energy consumption kwh (cooling)  
Max Current Cooling A 13.5
Heating A 11.7
Max Power input Cooling W 2472
Heating W N.A
       
Refrigerant/Charge Gram R410A/R22
Compressor Type Rotary
Model QX-D336F030
LRA A /
MFG GREE
       
Indoor air circulation(Cooling/Heating) m3/h 800/850
Indoor fan type Cross flow
Indoor fan speed H/M/L Cooling rpm 1300/1140/980
Heating rpm 1300/1140/980
Dry rpm 980
Sleep rpm 980
Indoor fan motor output W 18
Outdoor fan type Propeller
Outdoor fan speed rpm 850
Outdoor fan motor output W 45
       
Connecting Pipe Gas mm Φ12
Liquid mm Φ6
Connecting Wiring Size x Core number 5*1.5
Drainage Pipe  
       
Suitable area m2 20~30
Net dimensions (W x H x D) Indoor mm 860*299*190
Outdoor mm 820*600*300
Net weight Indoor kg 13
Outdoor kg 39
Packing dimensions (W x H x D) Indoor mm 910*365*265mm
Outdoor mm 920*405*645
Gross weight Indoor kg 15.5
Outdoor kg 41/42

 

Precautions

- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;

- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;

When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;

- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;

- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged

- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2015

  • Total Annual:

    8000000-10000000

  • Employee Number:

    500~700

  • Ecer Certification:

    Active Member

In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s... In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s...

+ Read More

Get in touch with us

  • Reach Us
  • ninghua Yuetu Technology Co., Ltd
  • NO. 6 Chengnan Industry Park,Ninghua, Sanming, Fujian, China
  • https://www.wallmountedac.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement