Payment Terms | L/C, D/A, D/P, T/T |
Supply Ability | 100000pcs/month |
Delivery Time | 35 work days after receipt of the deposit |
Packaging Details | Standard export carton box package suitable for container shipment. |
Panel Design | QA |
EER | 2.5~3.5 |
Logo | Oem or Yuetu |
Name | Wall Mounted Air Cond |
Paytmen term | TT/LC/OA |
Factory Certification | ISO |
Brand Name | YUETU or OEM |
Model Number | 18000BTU |
Certification | CE/BC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
50hz 220V R410a Wall Mounted AC Unit 24000BTU 7000W UA Panel
9000BTU Wall Mounted Split Type Aircon UA Panel 60hz 220V R410a
UA Panel 60hz 220V Wall Mounted AC Unit R410a 18000BTU GMCC
R410a 18000BTU Door Mounted Air Conditioner 60hz 220V UA Panel
Product Specification
Payment Terms | L/C, D/A, D/P, T/T | Supply Ability | 100000pcs/month |
Delivery Time | 35 work days after receipt of the deposit | Packaging Details | Standard export carton box package suitable for container shipment. |
Panel Design | QA | EER | 2.5~3.5 |
Logo | Oem or Yuetu | Name | Wall Mounted Air Cond |
Paytmen term | TT/LC/OA | Factory Certification | ISO |
Brand Name | YUETU or OEM | Model Number | 18000BTU |
Certification | CE/BC | Place of Origin | CHINA |
High Light | 48GW Wall Mounted Air Cond ,18000BTU Wall Mounted Air Cond ,1300RPM R32 Wall Mounted ac |
ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU
QA Panel 50HZ 220V R410a/R32 18000BTU Cooling Heating High Quality Wifi Control PCB 3 Year Warranty
18000BTU | |||
Model No. | TAC-18CHS/Z | ||
KFR-48GW | |||
indoor860(Φ7×2)+outdoor820(Φ7.94×2) | |||
Type | Heating Pump | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 15695;4600 | |
Rated heating capacity | Btu/h;W | 17674;5180 | |
EER for cooling | Btu/h.w; W/W | 2.4 | |
COP for heating | W/W | 2.64 | |
Moisture removal | Liters/h | 1.99 | |
Pressure | High(DP) | MPa | 2.6 |
Low(SP) | MPa | 1 | |
Indoor noise level at cooling | High | dB(A) | 42 |
Med. | dB(A) | 39 | |
Low | dB(A) | 36 | |
Outdoor noise level | dB(A) | 58 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 9.8 |
Heating | A | 9.5 | |
Rated input | Cooling | W | 2042 |
Heating | W | 1958 | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 13.5 |
Heating | A | 11.7 | |
Max Power input | Cooling | W | 2472 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R410A/R22 | |
Compressor | Type | Rotary | |
Model | QX-D336F030 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 800/850 | |
Indoor fan type | Cross flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1300/1140/980 |
Heating | rpm | 1300/1140/980 | |
Dry | rpm | 980 | |
Sleep | rpm | 980 | |
Indoor fan motor output | W | 18 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 45 | |
Connecting Pipe | Gas | mm | Φ12 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*1.5 | |
Drainage Pipe | |||
Suitable area | m2 | 20~30 | |
Net dimensions (W x H x D) | Indoor | mm | 860*299*190 |
Outdoor | mm | 820*600*300 | |
Net weight | Indoor | kg | 13 |
Outdoor | kg | 39 | |
Packing dimensions (W x H x D) | Indoor | mm | 910*365*265mm |
Outdoor | mm | 920*405*645 | |
Gross weight | Indoor | kg | 15.5 |
Outdoor | kg | 41/42 |
Precautions
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
8000000-10000000
Employee Number:
500~700
Ecer Certification:
Active Member
In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s... In 2015, Yuetu moved to Ninghua from Wenzhou, and covering an area with 300,000 square meter. There are total 12 production lines with 3 million sets production capacity annually and 95% of the parts self produced, such as heat exchanger, welding, bending, automatic coating, plastic injection, and s...
Get in touch with us
Leave a Message, we will call you back quickly!