| Packaging Details | Neutral carton |
| Delivery Time | 5-8 working days |
| Payment Terms | Online order,T/T |
| Supply Ability | 100 Unit/Week |
| Test Method | 4-AAP (4-aminoantipyrine) spectrophotometric method |
| Measuring Range | 0~10mg/L (segmented measurement, expandable) |
| Detection Limit | ≤0.002mg/L |
| Resolution | 0.001mg |
| Accuracy | ±5% |
| Power Supply | AC 220±10% V |
| Dimensions | 520H × 370W × 265D (mm) |
| Weight | 40kg |
| Brand Name | JUGE |
| Model Number | AG9005 |
| Certification | IOS9001, CE |
| Place of Origin | Nanjing, China |
View Detail Information
Explore similar products
Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online
Online CODcr COD Water Quality Analyzer Potassium Dichromate Oxidation
Industrial Sewage Online Ammonia nitrogen Water Quality Analyzer
CODmn Permanganate Index Online Water Quality Analyzer
Product Specification
| Packaging Details | Neutral carton | Delivery Time | 5-8 working days |
| Payment Terms | Online order,T/T | Supply Ability | 100 Unit/Week |
| Test Method | 4-AAP (4-aminoantipyrine) spectrophotometric method | Measuring Range | 0~10mg/L (segmented measurement, expandable) |
| Detection Limit | ≤0.002mg/L | Resolution | 0.001mg |
| Accuracy | ±5% | Power Supply | AC 220±10% V |
| Dimensions | 520H × 370W × 265D (mm) | Weight | 40kg |
| Brand Name | JUGE | Model Number | AG9005 |
| Certification | IOS9001, CE | Place of Origin | Nanjing, China |
| High Light | Volatile phenol Water Quality Analyser ,Volatile phenol online water analyzer ,0.001mg Resolution Water Quality Analyser | ||
Volatile phenol Online Water Quality Analyzer
>>Overview
Phenols are categorized into volatile phenols and non-volatile phenols based on their ability to co-distill with water vapor. Volatile phenols typically refer to monohydric phenols with boiling points below 23°C. Phenolic compounds primarily originate from industrial effluents such as petroleum refining, gas scrubbing, coking, papermaking, synthetic ammonia production, wood preservation, and chemical manufacturing.
Phenols are highly toxic protoplasmic toxicants. Low concentrations denature proteins, while high concentrations precipitate proteins, causing direct damage to cells and severe corrosion to skin and mucous membranes. Long-term consumption of phenol-contaminated water may lead to dizziness, rashes, itching, anemia, nausea, vomiting, and neurological disorders. Phenolic compounds also exhibit cancer-promoting effects in humans and mammals.
This analyzer operates autonomously under long-term unattended continuous monitoring based on field configurations. It is widely applicable to industrial wastewater discharge, process wastewater, industrial and municipal sewage treatment plants, and similar environments. Depending on the complexity of on-site conditions, optional preprocessing systems can be integrated to ensure reliable testing processes, accurate results, and compliance with diverse operational demands.
>>Technical Parameter
| Test Method |
4-AAP (4-aminoantipyrine) spectrophotometric method |
| Measuring Range |
0~10mg/L (segmented measurement, expandable) |
| Detection Limit |
≤0.002mg/L |
| Resolution |
0.001mg/L |
| Accuracy |
±5% |
| Repeatability |
≤±5% |
|
Drift (24h) |
Zero drift: ±5% Span drift: ±10% |
| Measurement Time |
<25min (digestion time adjustable) |
| Measurement Modes |
Adjustable time interval, fixed time point, or triggered measurement |
|
Calibration Modes |
Automatic calibration (1~99 days adjustable) Manual calibration based on actual water samples |
|
Maintenance Cycle |
|
| Human-Machine Interface |
Touchscreen display and command input |
|
Self-Diagnosis & Protection |
Self-diagnoses operational status; retains data during anomalies/power outages Automatically clears residual reactants and resumes operation after reset/power recovery |
| Data Storage |
5-year data capacity |
| Input Interface |
Digital input |
|
Output Interfaces |
1× RS232, 1× RS485 2× 4~20mA analog outputs |
|
Operating Environment |
Indoor use; recommended temperature: 5~28℃, humidity ≤90% (non-condensing) |
|
Power Supply |
Voltage: AC 220±10% V Frequency: 50±0.5 Hz Power: ≤150W (excluding sampling pump) |
|
Dimensions |
520H × 370W × 265D (mm) |
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
2000000-3000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref... JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref...
Get in touch with us
Leave a Message, we will call you back quickly!