| Packaging Details | Neutral carton |
| Delivery Time | 5-8 working days |
| Payment Terms | Online order,T/T |
| Supply Ability | 100 Unit/Week |
| Test Method | Potassium persulfate oxidation-resorcinol spectrophotometric method |
| Measuring Range | 0~300mg/L (segmented measurement, expandable) |
| Repeatability | ±10% |
| Zero Drift | ±5% |
| Span Drift | ±10% |
| Power Supply | AC 220±10% V |
| Dimensions | 520H × 370W × 265D (mm) |
| Weight | 40kg |
| Brand Name | JUGE |
| Model Number | AG9003 |
| Certification | IOS9001, CE |
| Place of Origin | Nanjing, China |
View Detail Information
Explore similar products
Nessler Spectrophotometric Method Ammonia Nitrogen Water Quality Online
Online CODcr COD Water Quality Analyzer Potassium Dichromate Oxidation
Industrial Sewage Online Ammonia nitrogen Water Quality Analyzer
CODmn Permanganate Index Online Water Quality Analyzer
Product Specification
| Packaging Details | Neutral carton | Delivery Time | 5-8 working days |
| Payment Terms | Online order,T/T | Supply Ability | 100 Unit/Week |
| Test Method | Potassium persulfate oxidation-resorcinol spectrophotometric method | Measuring Range | 0~300mg/L (segmented measurement, expandable) |
| Repeatability | ±10% | Zero Drift | ±5% |
| Span Drift | ±10% | Power Supply | AC 220±10% V |
| Dimensions | 520H × 370W × 265D (mm) | Weight | 40kg |
| Brand Name | JUGE | Model Number | AG9003 |
| Certification | IOS9001, CE | Place of Origin | Nanjing, China |
| High Light | customization Total Nitrogen Analyzer ,Online Water Analyzer Customization ,TN Online Water Analyzer | ||
TN Online Total Nitrogen Water Quality Analyzer
>>Overview
Total nitrogen in water primarily originates from nitrogenous organic matter decomposed by microorganisms in domestic wastewater, industrial effluents such as coking and synthetic ammonia production, and agricultural drainage. Elevated total nitrogen levels in water bodies pose toxic effects on aquatic life and varying degrees of harm to humans. Measuring total nitrogen concentrations aids in assessing water pollution levels and "self-purification" status, making it a critical indicator of water quality contamination.
This analyzer operates autonomously under long-term unattended and continuous operation based on field configurations. It is widely applicable to industrial wastewater discharge, municipal sewage treatment plants, environmental surface water monitoring, and similar scenarios. Depending on on-site complexity, optional preprocessing systems can be integrated to ensure reliable testing processes, accurate results, and compliance with diverse operational demands.
>>Principle
The analyzer employs the potassium persulfate oxidation-resorcinol spectrophotometric method. After mixing the water sample with a masking agent, total nitrogen (existing as free ammonia, ammonium ions, or other forms) reacts with potassium persulfate under alkaline conditions in the presence of a sensitizing agent, forming a colored complex. The analyzer detects this chromatic change, converts it into a total nitrogen concentration value, and outputs the result. The intensity of the colored complex corresponds to the total nitrogen concentration.
>>Technical Parameter
| Test Method |
Potassium persulfate oxidation-resorcinol spectrophotometric method |
| Measuring Range |
0~300mg/L (segmented measurement, expandable) |
|
Indication Error |
≤±0.2mg/L for standard solutions/samples ≤2mg/L ≤±10% for standard solutions/samples ≥2.0mg/L |
| Repeatability |
±10% |
|
Drift (24h) |
Zero Drift: ±5% Span Drift: ±10% |
|
Linearity |
±10% |
| Measurement Time |
<50min (digestion time adjustable) |
| Measurement Modes |
Adjustable time interval, fixed time point, or triggered measurement |
|
Calibration Modes |
Automatic calibration (1~99 days adjustable) Manual calibration based on actual water samples |
|
Maintenance Cycle |
|
| Human-Machine Interface |
Touchscreen display and command input |
|
Self-Diagnosis & Protection |
Self-diagnoses operational status; retains data during anomalies/power outages Automatically clears residual reactants and resumes operation after reset/power recovery |
| Data Storage |
5-year data capacity |
| Input Interface |
Digital input |
|
Output Interfaces |
1× RS232, 1× RS485 2× 4~20mA analog outputs |
|
Operating Environment |
Indoor use; recommended temperature: 5~28℃, humidity ≤90% (non-condensing) |
|
Power Supply |
Voltage: AC 220±10% V Frequency: 50±0.5 Hz Power: ≤150W (excluding sampling pump) |
|
Dimensions |
520H × 370W × 265D (mm) |
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
2000000-3000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref... JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref...
Get in touch with us