China factories

China factory - Dongguan Ruixiang Machinery Co., Ltd

Dongguan Ruixiang Machinery Co., Ltd

  • China,Dongguan ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China R23 Laboratory Recirculating Water Chiller Air Cooled Customizable
China R23 Laboratory Recirculating Water Chiller Air Cooled Customizable

  1. China R23 Laboratory Recirculating Water Chiller Air Cooled Customizable

R23 Laboratory Recirculating Water Chiller Air Cooled Customizable

  1. MOQ: 1 set
  2. Price: RMB 6500-800000/PC
  3. Get Latest Price
Place Of Origin Dongguan China
Packaging Details Wooden Box Packaging
Delivery Time 15-20 Units
Payment Terms T/T
Supply Ability 500days
Evaporator Type Plate, Shell And Tube
Display LCD Touch Screen
Pump Type Centrifugal, Magnetic Drive
Refrigerant R404A, R407C, R134A, R23
Safety Features High And Low Pressure Protection, Overload Protection, Anti-freezing Protection
Temperature Range -80°C To 10°C
Condenser Type Air-cooled, Water-cooled
Communication Interface RS485, Ethernet
Brand Name Ruixiang
Model Number RX-12HP
Certification ISO9001/CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Place Of Origin Dongguan China Packaging Details Wooden Box Packaging
Delivery Time 15-20 Units Payment Terms T/T
Supply Ability 500days Evaporator Type Plate, Shell And Tube
Display LCD Touch Screen Pump Type Centrifugal, Magnetic Drive
Refrigerant R404A, R407C, R134A, R23 Safety Features High And Low Pressure Protection, Overload Protection, Anti-freezing Protection
Temperature Range -80°C To 10°C Condenser Type Air-cooled, Water-cooled
Communication Interface RS485, Ethernet Brand Name Ruixiang
Model Number RX-12HP Certification ISO9001/CE
High Light R23 Laboratory Recirculating Water ChillerR23 ultra low temp chillerCustomizable Laboratory Recirculating Water Chiller

12 HP 12 Ton Portable Low Temperature Glycol Chiller

 

Production Description:


The air-cooled low-temperature chiller is a low-temperature refrigeration equipment that uses air-cooled cooling. It is mainly composed of compressor, condenser, evaporator, electric control system, etc., and realizes the purpose of cooling and cooling through the change of refrigerant in the cycle.

 


JLSFD-10HP Low Temperature Chiller , Scroll Air Cooled Industrial Chiller 0
 

Production Features:


The air-cooled low-temperature chiller has the following characteristics:

 

1.Low-temperature refrigeration: Air-cooled low-temperature chillers can realize low-temperature refrigeration, which can meet the needs of some special industries for low-temperature refrigeration, such as medicine, food and other industries.

 

2.High efficiency and energy saving: Air-cooled cooling method is adopted, no additional water circulation system is required, water resources are saved, water treatment costs are reduced, and the cooling efficiency of the equipment is also improved.

 

3.Easy to operate: It has an intelligent control system, which can realize automatic and intelligent operation and control, and is easy to operate.

 

4.Wide range of applications: Air-cooled low-temperature chillers can be used in many industries, such as medicine, food, chemical and other industries, and have broad application prospects.

 

In short, the air-cooled low-temperature chiller is a low-temperature refrigeration equipment, which has the characteristics of low-temperature refrigeration, high efficiency and energy saving, easy operation, and wide application. It is suitable for the low-temperature refrigeration needs of many industries.

 

 

Working Principle:


Specifically, the working principle of the air-cooled low-temperature chiller is:

1.The compressor sucks in low-temperature and low-pressure refrigerant and compresses it into a high-temperature and high-pressure gas.

 

2.The high-temperature and high-pressure gas enters the condenser, releases heat into the air through the radiator, and turns into a high-temperature and high-pressure liquid.

 

3.The high-temperature and high-pressure liquid enters the evaporator, exchanges heat with the outside through the evaporator, and turns into low-temperature and low-pressure steam.

 

4.The low-temperature and low-pressure steam enters the compressor again, and the cycle repeats.



JLSFD-10HP Low Temperature Chiller , Scroll Air Cooled Industrial Chiller 1

 

Techinical Parameters:

Model RX-3HP RX-5HP RX-10HP RX-20HP RX-30HP RX-40HP RX-50HP RX-60HP
Cooling capacity KW/h 9.3 15.5 31 77.5 93 124 155 186
  Kcal/h 8,100 13,500 27,000 61,683 74,992 97,675 116,521 156,249
Temperature range -30℃~35℃
Power supply 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ
Total power KW 6.2 10.3 19.8 22.75 28.3 39.2 46.75 56.1
Compressor Type   Hermetic scroll type or piston
  Power KW 2.25 3.75 7.5 15 22.5 30 37.5 45
Circulating pump Power KW 1.5 1.5 2.2 2.2 4 4 4 5.5
  Head m 21.5 21.5 22 22 25 25 25 26
Refrigerant Type   R22/R407c/R404a/R410a
  Control method   Temperature Sensing External Pressure Equalizing Expansion Valve
  filling volume Kg 7.2 9.1 12.2 15.3 18.6 24.5 30.6 36.8
Evaporator Flow m³/h 5.81 7.6 10.16 12.34 15.2 19.53 23.3 30.52
  water capacity m³/h 0.18 0.21 0.28 0.32 0.32 0.61 0.66 0.72
  Diameter inch 1.5" 2" 2.5" 3"
Condensator Type   Efficient brass sets corrugated aluminum fin
Fan Type   Axial flow
  air volume m³/h 12000 15000 20000 25000 30000 40000 50000 60000
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 1400 1750 2000 2000 2200 2000 2000 2400
  W mm 725 750 900 900 900 1800 1800 1800
  H mm 1450 1500 1770 1770 1770 2200 2300 2300
Unit weight Kg 370 480 590 590 880 1000 1280 1420

 


Application Industry:


Cryogenic chillers are commonly used in industries and applications that require operation at low temperatures. The following are some common low temperature chiller application industries:

 

1.Refrigeration and air-conditioning industry: Low-temperature chillers can be used in refrigeration and air-conditioning systems to provide cooling services for buildings, commercial facilities, and industrial equipment.

 

2.Food processing industry: Low-temperature chillers can be used in food processing industries, such as freezing, refrigeration, quick freezing and cooling.

 

3.Medical industry: Low-temperature chillers can be used for refrigeration equipment in the pharmaceutical and biotechnology industries, such as low-temperature refrigerators, medical refrigerators, refrigerated trucks, and freeze dryers.

 

4.Chemical industry: Low temperature chillers can be used in chemical and pharmaceutical industries, such as synthesis reactions, cooling and freezing, etc.

 

5.Electronics industry: Low-temperature chillers can be used in semiconductor manufacturing and testing equipment in the electronics industry, such as low-temperature processing and testing of semiconductor materials.

 

6.Aerospace industry: Cryogenic chillers can be used for testing equipment and refrigeration equipment in the aerospace industry, such as cryogenic test chambers and refrigeration equipment for propulsion systems.

 

7.Metallurgical industry: Low-temperature chillers can be used for refrigeration equipment in the metallurgical industry, such as cooling and freezing in metallurgical reactions.

 

In conclusion, low temperature chillers are widely used in many industries and applications to meet the needs of low temperature refrigeration in different fields.

 

JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 1 JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 2 JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 4
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

 

JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 6 JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 7 JLSF-100D Air Cooled Screw Chiller High Efficiency Energy Saving Good Stability air conditioner Refrigeration 8

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

 

 

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

Precautions:


The low-temperature chiller is a special refrigeration equipment, and the following items should be paid attention to when using it:

1.Safety precautions: The use of low-temperature chillers involves low-temperature refrigerants and high-pressure refrigerants, and relevant safety regulations and operating procedures must be followed, such as wearing protective clothing and protective gloves.

 

2.Regular maintenance: Low-temperature chillers must be regularly maintained and maintained, including cleaning the refrigeration system, replacing filters, and checking the electrical system, etc., to ensure the normal operation of the equipment and extend the life of the equipment.

 

3.Temperature control: When the low-temperature chiller is used, the temperature of the equipment must be well controlled to avoid over-cooling or overheating, which will affect the performance and life of the equipment.

 

4.Air circulation: When using low-temperature chillers, it is necessary to ensure that the air circulation around the equipment is good to avoid overheating or overcooling of the equipment, and at the same time prevent the equipment from being polluted by external substances.

 

5.Operation skills: The operation of low-temperature chillers requires certain professional knowledge and skills, such as understanding the characteristics of refrigerants, mastering the operation methods and adjustment methods of the equipment, etc.

 

6.Environmental protection precautions: In the use and maintenance of low-temperature chillers, it is necessary to pay attention to environmental protection issues, such as correct disposal of waste refrigerants and waste equipment components, etc., to reduce the impact on the environment.

 

In short, when using low-temperature chillers, you need to pay attention to many aspects, including safety, maintenance, temperature control, air circulation, operating skills and environmental protection, to ensure the normal operation of the equipment and extend the life of the equipment.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2012

  • Total Annual:

    10000000-15000000

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

Dongguan Ruixiang Machinery Co., Ltd. is a modern enterprise focusing on the research and development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. It has strong resea... Dongguan Ruixiang Machinery Co., Ltd. is a modern enterprise focusing on the research and development, production, sales and service of industrial temperature control equipment. Since its establishment, the company has been focusing on the field of industrial temperature control. It has strong resea...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Ruixiang Machinery Co., Ltd
  • Building 1, No. 12, Shentian 4th Road, Hengli Town, Dongguan City, Guangdong Province
  • https://www.waterchillersolutions.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!