| Packaging Details | Wooden Case |
| Delivery Time | 35 days |
| Payment Terms | T/T |
| Supply Ability | 30 Units/Month |
| Flow Rate Stability | <0.1% |
| Eluent Concentration Range | KOH、MSA-0.1~100.0mM |
| Flow Rate Setting Rate | <0.1% |
| Pump Pressure | 0~42MPa |
| Column Capacity | 2pcs, 250mm And 150mm |
| Injection Volume | 10μL---4000μL |
| Quantitative Repeatability | ≤0.5% |
| Flow Rate Range | 0.001~12.000ml/min |
| Brand Name | Wayeal |
| Model Number | IC6600 |
| Place of Origin | Anhui, China |
| Certification | CE |
View Detail Information
Explore similar products
Wayeal IC Ion Chromatography Instrument Machine For Lab Water Analysis
Wayeal Ion Chromatography Systems Instrumentation Multi Functional ISO
Laboratory Use High Pressure Ion Chromatography Instrument 35Mpa
IC6200 PEEK Pump Ion Exchange Chromatography Instrument for Anions or Cations
Product Specification
| Packaging Details | Wooden Case | Delivery Time | 35 days |
| Payment Terms | T/T | Supply Ability | 30 Units/Month |
| Flow Rate Stability | <0.1% | Eluent Concentration Range | KOH、MSA-0.1~100.0mM |
| Flow Rate Setting Rate | <0.1% | Pump Pressure | 0~42MPa |
| Column Capacity | 2pcs, 250mm And 150mm | Injection Volume | 10μL---4000μL |
| Quantitative Repeatability | ≤0.5% | Flow Rate Range | 0.001~12.000ml/min |
| Brand Name | Wayeal | Model Number | IC6600 |
| Place of Origin | Anhui, China | Certification | CE |
Introduction of IC6600 Ion Chromatography Instrument
The IC6600 multi-functional ion chromatograph features an innovative modular design, offering flexible configurations and powerful capabilities. Equipped with an all-PEEK pump head, it is resistant to acids, bases, and reversed-phase organic solvents, thereby preventing metal contamination. Additionally, the system can be flexibly configured with conductivity detectors, amperometric detectors, or UV detectors to meet a wide range of user detection needs.
Technical Parameters of IC6600 Ion Chromatography Instrument
| Product Name | Multifunctional Ion Chromatography |
| Model | IC6600 |
| Working power | 220V, 50Hz |
| Ambient temperature | 10-40°C |
| Relative humidity | 20-85% |
| Qualitative repeatability | ≤0.1% |
| Quantitative repeatability | ≤0.5% |
| Pump flow rate range | 0.001~12.000mL/min |
| Pressure resistance of pump head | 0-40MPa |
| Flow setting error | <0.1% |
| Flow stability | <0.1% |
| Pressure display accuracy | 0.001MPa |
| Pressure plusation | <0.25% |
| Conductivity detector | |
| Baseline noise | ≤0.03%FS |
| Baseline drift | ≤0.1%FS |
| Mini detectable concentration (Cl): | ≤0.0001μg/mL |
| Mini detectable concentration (Li): | ≤0.00005μg/mL |
| Mini detectable concentration (NO3): | ≤0.001μg/mL |
| Mini detectable concentration (Na+): | ≤0.001μg/mL |
| Mini detectable concentration (Ca2+): | ≤0.005μg/mL |
| Conductivity cell volume | ≤0.4μL |
| Conductivity detection range | 0-45000μS/cm |
| Detector resolution | 0.00238nS/cm |
| Conductivity cell temperature setting error | ±0.01°C |
| Conductivity cell temperature display resolution | 0.001°C |
| Conductivity cell temperature control range | Detector temperature zone temperature +5°C-65°C |
| Conductivity cell temperature control stability | 0.05°C |
| Conductivity cell temperature setting value error | 0.1°C/h |
| Ampere detector | |
| Type | Thin-layer structure, automatic range |
| Driving voltage range | -2.0V-2.0V |
| Drive voltage resolution | 0.001V |
| Output signal range |
Integral mode: 50pc-200uC DC mode: 1pA-74μA |
| Noise |
Integration mode<30pC DC mode<5pA, DC mode static noise<1pA |
| Cell material | Titanium |
| Pool volume | <0.2μL |
| Maximum pool pressure | 0.7MPa |
| Minimum detectable concerntration | I-0.001μg/mL |
| Minimum detectable concerntration fructose | 0.01μg/mL |
| UV Detector | |
| Wavelength indication error | 0.1nm |
| Wavelength repeatability | 0.1nm |
| Mini detectable concentration | BrO3-0.0005μg/mL |
| Mini detectable concentration | CrO42-0.001μg/mL |
| Qualitative repeatability | ≤0.05% |
| Quantitative repeatability | ≤0.3% |
| Suppressor | |
| Dead volume | 50μL |
| Inhibition capacity | 170ueq/min |
| Pressure resistance | 3MPa |
| Column oven | |
| Temperature range | Room temperature +5°C~70°C |
| Temperature control stability | 0.1°C/h |
| Error of temperature setting value | 0.05°C |
| Autosampler | |
| Number of samples | ≥120 (1.5ml sample bottle) |
| Temperature | 4~30°C |
| Linear | >0.999 |
| Cross-contamination | <0.01% |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2003
Total Annual:
50 Million-100 Million
Employee Number:
1000~1300
Ecer Certification:
Verified Supplier
Anhui Wanyi Science & Technology Co., Ltd. (hereinafter referred to as Wayeal) was founded in 2003 and is listed on the Science and Technology Board of the Shanghai Stock Exchange (stock code: 688600). As a professional supplier of precision instruments, Wayeal’s business mainly covers Ind... Anhui Wanyi Science & Technology Co., Ltd. (hereinafter referred to as Wayeal) was founded in 2003 and is listed on the Science and Technology Board of the Shanghai Stock Exchange (stock code: 688600). As a professional supplier of precision instruments, Wayeal’s business mainly covers Ind...
Get in touch with us