| Payment Terms | T/T |
| Supply Ability | 500set/month |
| Delivery Time | 30days |
| Packaging Details | Plywood case |
| Type | Substation Transformer |
| Operation | Step-Up |
| Capacity | 6500KVA |
| Primary Voltage | 480Y/277-480Y/277 |
| Secondary Voltage | 13800V |
| Vector group | Dyn11,yn11 |
| Cooling Class | ONAN; Self-Cooled |
| Standard | IEC60076 |
| Brand Name | WINLEY |
| Model Number | S-6500/13.8 |
| Certification | CE,ISO |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
2500kva Three Phase Pad Mounted Transformer ANSI IEEE Standard Electric Power 12
167kva Single Phase Pole Mounted Transformer CSP Type oil immersed distribution
167Kva Oil Immersed Single Phase Pad Mounted Transformer 12.47Kv
10MVA Three Phase Substation Transformer Oil Type Step Down 22.9KV To 4160V
Product Specification
| Payment Terms | T/T | Supply Ability | 500set/month |
| Delivery Time | 30days | Packaging Details | Plywood case |
| Type | Substation Transformer | Operation | Step-Up |
| Capacity | 6500KVA | Primary Voltage | 480Y/277-480Y/277 |
| Secondary Voltage | 13800V | Vector group | Dyn11,yn11 |
| Cooling Class | ONAN; Self-Cooled | Standard | IEC60076 |
| Brand Name | WINLEY | Model Number | S-6500/13.8 |
| Certification | CE,ISO | Place of Origin | CHINA |
| High Light | 6500KVA Substation Transformer ,480V to 13800V Power Transformer ,Dyn11 ,yn11 Oil Type Transformer | ||
A Solar Double-Split Step-Up Transformer is a specialized transformer tailored for solar power systems. It uses dual split windings to efficiently raise the low-voltage output from solar panels (or an inverter) to a higher voltage suitable for grid connection or energy storage. The transformer splits the input across two separate windings and steps it up while preserving electrical isolation, thereby enhancing both efficiency and safety.
![]()
![]()
![]()
![]()
| SF-6500/13.8/0.48-0.48 specification data | |||
| No. | Particulars | Unit | Specification |
| 1 | Type | ~ | oil immersed, conservator type |
| 2 | Rated power | kVA | 6500 |
| 3 | Power 1 | kVA | 3700KVA, Max. current 6000A |
| 4 | Power 2 | kVA | 2800KVA, Max. current 4500A |
| 5 | No. of Phase | ~ | 3 |
| 6 | Primary voltage | V | 480Y/277-480Y/277 |
| 7 | Primary connection 1 | ~ | (4) 16-hole spade |
| 8 | Primary connection 2 | ~ | (4) 12-hole spade |
| 9 | Secondary voltage | V | 13800 |
| 10 | Secondary connection | ~ | (3) 15kV Porcelain bushing |
| 11 | Tapping type | ~ | off circuit |
| 12 | Tapping range | % | ±2*2.5% |
| 13 | Cooling method | ~ | ONAN |
| 14 | Rated frequency | Hz | 60 |
| 15 | Vector group | ~ | Dyn11,yn11 |
| 16 | Insulation class | ~ | A |
| 17 | Ambiant temperature | ℃ | from -10 to 40 |
| 18 | Temperature rise | K | 65 |
![]()
![]()
Large photovoltaic power plants use 500 kW as the basic generation unit, and 500 kW inverters are the market standard. Connecting the inverter to the prefabricated (box-type) substation is a critical step in the PV system, so the design must balance cost control with technical soundness. The double-split transformer therefore offers an ideal voltage-boosting solution.
![]()
| Substation Transformer Specification | |||||
| kVA | HV | LV | Width(mm) | Length(mm) | Height(mm) |
| 315kVA | 11000V | 400V | 800 | 696 | 1336 |
| 500kVA | 27600V | 480GrdY/277V | 1730 | 2300 | 1510 |
| 500kVA | 11000V | 415V | 1700 | 1700 | 1650 |
| 750kVA | 11000V | 433V | 1850 | 1845 | 1465 |
| 1000kVA | 14400V | 415/240V | 1085 | 1860 | 1570 |
| 1200kVA | 13800V | 240V | 2450 | 1850 | 1820 |
| 1500kVA | 24940V | 600V | 1800 | 1880 | 1895 |
| 2000kVA | 7200V | 600GrdY/346 | 1766 | 2680 | 1982 |
| 2000kVA | 44000V | 600V | 1260 | 2090 | 1700 |
| 2500kVA | 24940V | 480GrdY/277V | 2400 | 2200 | 2060 |
| 3000kVA | 11000V | 415V | 1600 | 2330 | 1920 |
| 3000kVA | 22800V | 415/240V | 2130 | 3500 | 1910 |
| 3750kVA | 44000V | 600V | 2240 | 2650 | 2700 |
| 4000kVA | 33kV | 600Y/347 | 2150 | 3250 | 2290 |
| 5000kVA | 34500V | 7200V | 3780 | 1850 | 3450 |
| 5000kVA | 34500V | 4160V | 2799 | 2400 | 2938 |
| 6300kVA | 35000V | 400V | 3520 | 2820 | 3470 |
| 6800kVA | 34500V | 800V | 3400 | 2670 | 3400 |
| 7500kVA | 27600Y | 4160V | 3350 | 3290 | 2270 |
![]()
![]()
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$15M-$20M
Employee Number:
50~70
Ecer Certification:
Verified Supplier
WINLEY is located in Xiamen, China. We are specialized in manufacturing all kinds of transformers, voltage stabilizers, voltage regulators, etc. The products are widely used in industrial machinery, new energy, power generation, power supply, coal, metallurgy, petroleum, chemical, construction,... WINLEY is located in Xiamen, China. We are specialized in manufacturing all kinds of transformers, voltage stabilizers, voltage regulators, etc. The products are widely used in industrial machinery, new energy, power generation, power supply, coal, metallurgy, petroleum, chemical, construction,...