China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE
China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE

  1. China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE
  2. China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE
  3. China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE
  4. China 225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE

225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE

  1. MOQ: 1unit
  2. Price: $1000-$100000
  3. Get Latest Price
Supply Ability 500set/month
Standard ANSI/IEEE
Phase Three Phase
Delivery Time 30days
Secondary Voltage 480Y/277V
Payment Terms T/T
Temperature Rise 85K
Cooling Class AN/AF
Capacity 225kVA
Type Dry type, Cast Resin Transformer
Primary Voltage 12470V
Packaging Details Plywood case
Model Number SCL14-225/12.47
Certification CE ISO
Brand Name WINLEY
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 500set/month Standard ANSI/IEEE
Phase Three Phase Delivery Time 30days
Secondary Voltage 480Y/277V Payment Terms T/T
Temperature Rise 85K Cooling Class AN/AF
Capacity 225kVA Type Dry type, Cast Resin Transformer
Primary Voltage 12470V Packaging Details Plywood case
Model Number SCL14-225/12.47 Certification CE ISO
Brand Name WINLEY Place of Origin CHINA
High Light 225kVA cast resin dry type transformerthree phase transformer 12470V to 480Y/277VANSI/IEEE DOE 2016 cast coil transformer
225kVA Three Phase Cast Resin Dry Type Transformer 12470V to 480Y/277V ANSI/IEEE DOE 2016 Standards
Product Overview

This 225kVA three phase cast resin dry type transformer is designed for 12470V primary to 480Y/277V secondary power distribution in North American commercial buildings and light industrial facilities. Built with a NEMA 3R pad/floor mounted enclosure and configured to ANSI/IEEE C57.12.01 and DOE 2016 requirements, it suits utility-fed electrical rooms, outdoor equipment pads and facility service upgrades where medium-voltage supply needs to be stepped down for 480V equipment and 277V branch circuits.

Its cast resin dry type structure provides an oil-free installation advantage for projects where liquid containment, oil maintenance or indoor environmental restrictions must be considered. This makes it practical for facility distribution points that require enclosed equipment, service access and stable dry-type operation.



Why Choose Us


1. Winley Electric manufactures cast resin transformers up to 10 MVA and 35 kV, designed in accordance with applicable ANSI/IEEE, AS 60076, IEC 60076 and related dry-type transformer standards.
2. Winley Electric cast resin transformers are engineered for demanding applications, offering high overload capability, low maintenance needs, strong mechanical strength, and reliable short-circuit withstand performance.
3. Winley Electric has extensive experience in cast resin transformer projects and can tailor product designs for solar PV, data centers, and other applications, including dual-split winding designs, multi-tap designs, and other customized electrical configurations.



Product Photos 






Main Data


Item Data
Product type Three phase cast resin dry type distribution transformer
Rated capacity 225 kVA
Phase 3 Phase
Primary voltage 12470V
Secondary voltage 480Y/277V
Frequency 60Hz
Vector group Dyn1
HV BIL / LV BIL 95 kV / 30 kV
Cooling method AN / AF
Winding material Aluminum
No-load loss 486.0W
Load loss 2456.6W
Impedance 4.92%
Efficiency 99%
Dimensions 71L × 59W × 71H inch
Weight 3610 lbs



Technical drawings




Standard Features

  • NEMA 3R Enclosure
    Provides weather-resistant protection for indoor or outdoor pad/floor mounted installation.
  • Cooling Fans
    Supports forced-air ventilation to help manage transformer operating temperature.
  • Temperature Controller
    Monitors transformer temperature and supports alarm or control signal output.
  • PT100 Temperature Sensors in LV Coil
    Detects winding temperature and sends accurate temperature signals to the controller.
  • LV Copper Busbar
    Provides a reliable low-voltage connection point for outgoing power distribution.
  • HV Copper Busbar
    Provides a defined high-voltage connection structure for primary-side wiring.
  • 3 × 15A Fuse
    Provides primary-side circuit protection for the transformer.
  • Auxiliary Transformer BK-1, 240V IN / 220V OUT
    Supplies control power for auxiliary devices inside the enclosure.
  • Temperature and Humidity Controller
    Helps manage enclosure temperature and humidity for more stable internal conditions.
  • Aluminum Alloy Heater
    Helps reduce condensation risk inside the enclosure in humid or low-load conditions.
  • Fan Fuse
    Provides circuit protection for the cooling fan system.
  • Comm Socket / Sensor Socket
    Provides connection points for communication and sensor wiring.
  • Fault / Door-Open Signal / Fan / Alarm / Power Off / Power Indication
    Provides operating status signals for monitoring, alarm and maintenance reference.


Applications
  • Sector: Commercial Buildings and Facility Service Entrances
    Suitable applications: Utility-fed 12.47kV service rooms, building distribution switchboards, HVAC power supply and 277V lighting distribution.
  • Sector: Light Industrial Facilities
    Suitable applications: Workshops, small production areas, packaging lines, pumps, fans and 480V distribution panels.
  • Sector: Outdoor Electrical Rooms and Customer-Owned MV Distribution Points
    Suitable applications: Outdoor equipment pads, facility electrical rooms, customer-owned medium-voltage distribution points and campus utility feeders.
  • Sector: Retrofit and Replacement Projects
    Suitable applications: Replacing or upgrading existing 12.47kV to 480Y/277V dry-type transformers in commercial or industrial facilities.


Specification

Rated capacity
(KVA)

High Voltage
(KV)

Low
Voltage
(KV)

Connection Symbol

No-Load Loss
(W)

On-Load Loss
(W)

No Load Current
(%)

Weight
(KG)

Dimension 

L*W*H(mm)

 

100




6

6.3

10

10.5

11






0.4





Dyn11
Yyn0

540

1990

 2.4

 520

 1600*1300*2200

315

970

4080

 1.8

 1085

 1800*1350*2200

500

1350

5790

 1.8

 1520

 2000*1400*2200

630

1530

 6840

 1.6

 1820

 2000*1400*2200

1000

2070

 9780

 1.4

 2550

 2450*1450*2200

1250

2380

11500 

 1.4

 2900

 2300*1500*2200

1600

2790

13800

 1.4

 3490

 2400*1550*2200

2000

3240

16300

 1.2

 4220

 2600*1600*2200

2500

3870

 19300

 1.2

 4955

 2600*1600*2200


Production Process





Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2007

  • Total Annual:

    $45M-$60M

  • Employee Number:

    150~210

  • Ecer Certification:

    Verified Supplier

R&D and production capabilities   Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities   Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...

+ Read More

Get in touch with us

  • Reach Us
  • Xiamen Winley Electric Co.,Ltd
  • No. 99 Yilan Road,Siming,Xiamen,Fujian,China
  • https://www.winley-electric.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement