| Supply Ability | 500set/month |
| Type | Conventional single-phase pole-mounted distribution transformer |
| Cooling Class | ONAN |
| Capacity | 5kVA |
| Primary Voltage | 24940Y/14400V |
| Delivery Time | 30 days |
| Frequency | 60HZ |
| Payment Terms | T/T |
| Operation | Step-down |
| Secondary Voltage | 120/240V |
| Packaging Details | Plywood case |
| Standard | ANSI/IEEE |
| Model Number | D11-5/24.94/0.24-0.12 |
| Certification | UL, cUL |
| Place of Origin | CHINA |
| Brand Name | WINLEY |
View Detail Information
Explore similar products
167kva Single Phase Pole Mounted Transformer CSP Type oil immersed distribution
Submersible Transformers Underground Vault Installation 25 Kva 13.8KV To 120V
CSA Standard 50kva Pole Mounted Transformer Oil Type 13856V To 120v cUL
15kva Pole Mount Distribution Single Phase Transformer Oil Immersed 4160v To
Product Specification
| Supply Ability | 500set/month | Type | Conventional single-phase pole-mounted distribution transformer |
| Cooling Class | ONAN | Capacity | 5kVA |
| Primary Voltage | 24940Y/14400V | Delivery Time | 30 days |
| Frequency | 60HZ | Payment Terms | T/T |
| Operation | Step-down | Secondary Voltage | 120/240V |
| Packaging Details | Plywood case | Standard | ANSI/IEEE |
| Model Number | D11-5/24.94/0.24-0.12 | Certification | UL, cUL |
| Place of Origin | CHINA | Brand Name | WINLEY |
| High Light | 5kVA single phase pole mounted transformer ,UL listed rural service transformer ,24940Y/14400V to 120/240V transformer | ||
Engineered for North American overhead distribution, this 5kVA single-phase pole-mounted transformer steps down 24.94kV grounded-wye lines (14.4kV phase-to-neutral) to two independent 120/240V split-phase outputs.
Built with all-copper windings, 125kV BIL insulation, and standard mineral oil cooling (ONAN), this unit delivers exceptionally reliable performance for rural drops, agricultural facilities, and remote infrastructure. Its unique dual-secondary design allows utilities and operators to power two separate low-voltage circuit groups from a single pole location—saving equipment cost and pole space while ensuring standard-compliant isolation.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Conventional single-phase pole-mounted distribution transformer | Model | D11-5/24.94/0.24-0.12 |
| Rated Capacity | 5kVA | Phase | Single phase |
| Primary Voltage | 24940Y/14400V | Secondary Voltage | 2 × 120/240V |
| Frequency | 60Hz | BIL | 125kV HV, 30kV LV |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Transformer Configuration | Liquid-filled, conventional pole-mounted | Cooling Method | ONAN |
| Insulating Liquid | Type II non-PCB mineral oil | Winding Material | Copper |
| Core Material | Cold-rolled grain-oriented steel | Insulation Class | Class E, 120°C |
| Temperature Rise | 65°C | Ambient Range | -40°C to +40°C |
| Dimensions | Approx. 18.9 W × 25.1 D × 51.2 H in | Total Mass | 406 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| Short-Circuit Impedance at 85°C | 2.11–2.15% | No-Load Loss | 19.9–22.0W |
| Load Loss at 85°C | 61.5–63.2W | No-Load Current | 0.80–0.89% |
Ideal for remote residences, cabins, small farms, barns, and agricultural pump systems connected to 24.94kV grounded-wye overhead feeders.
Provides dependable power for irrigation controls, livestock equipment, gate automation, outdoor lighting, and remote monitoring systems.
Supports traffic signals, communication equipment, security systems, municipal control cabinets, and other small distributed loads along overhead networks. distribution point.
Suitable for low-capacity overhead distribution extensions and replacement projects requiring 14.4kV phase-to-neutral input and 120/240V service power.
| Rated Capacity (kVA) | High Voltage (kV) | No Load Loss (W) | On Load Loss (W) | Height (mm) | Depth (mm) | Width (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 15kVA |
34.5/19.92 13.8/7.96 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 294 |
| 25kVA | 80 | 290 | 840 | 740 | 610 | 362 | |
| 37.5kVA | 106 | 360 | 840 | 760 | 610 | 476 | |
| 50kVA | 135 | 500 | 840 | 810 | 610 | 553 | |
| 75kVA | 190 | 650 | 840 | 860 | 610 | 672 | |
| 100kVA | 280 | 1010 | 910 | 1200 | 965 | 714 | |
| 167kVA | 435 | 1530 | 1000 | 1200 | 965 | 913 | |
| 250kVA | 550 | 2230 | 1250 | 1300 | 1430 | 1106 |
A: Winley delivers standard pole-mounted distribution transformers within 30 days after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support, we ensure highly cost-effective and reliable solutions.
A: Yes. We accept OEM and ODM. Winley pole-mounted distribution transformers are available in standard ratings from 15-333 kVA (and maximum capability up to 500kVA), with HV systems up to 34.5 kV. According to customer drawings, we can customize secondary voltage, conventional or CSP design, copper or aluminum windings, low-carbon steel or stainless-steel tanks, tap changers, surge arresters, secondary circuit breakers, meter sockets and custom colors. We also integrate components from brands such as Qualitrol and Eaton Cooper.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E543292, designed strictly in compliance with ANSI/IEEE, CSA, DOE, NEMA and IEC 60076 to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, UL/cUL certs, DOE 2016 docs and accessory manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.
A: Yes. Winley matches existing nameplates, utility specifications, mounting dimensions and protection configurations for replacement projects.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...
Get in touch with us
Leave a Message, we will call you back quickly!