| Standard | ANSI/IEEE |
| Supply Ability | 500set/month |
| Operation | Step-down |
| Secondary Voltage | 120/240V |
| Delivery Time | 30 days |
| Cooling Class | ONAN |
| Payment Terms | T/T |
| Connection Symbol | Ii0 |
| Capacity | 75kVA |
| Type | Single-phase Pole-mounted Overhead Distribution Transformer |
| Primary Voltage | 24940Y/14400V |
| Packaging Details | Plywood case |
| Model Number | D11-75/24.94/0.12-0.24 |
| Certification | UL, cUL |
| Brand Name | WINLEY |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
167kva Single Phase Pole Mounted Transformer CSP Type oil immersed distribution
Submersible Transformers Underground Vault Installation 25 Kva 13.8KV To 120V
CSA Standard 50kva Pole Mounted Transformer Oil Type 13856V To 120v cUL
15kva Pole Mount Distribution Single Phase Transformer Oil Immersed 4160v To
Product Specification
| Standard | ANSI/IEEE | Supply Ability | 500set/month |
| Operation | Step-down | Secondary Voltage | 120/240V |
| Delivery Time | 30 days | Cooling Class | ONAN |
| Payment Terms | T/T | Connection Symbol | Ii0 |
| Capacity | 75kVA | Type | Single-phase Pole-mounted Overhead Distribution Transformer |
| Primary Voltage | 24940Y/14400V | Packaging Details | Plywood case |
| Model Number | D11-75/24.94/0.12-0.24 | Certification | UL, cUL |
| Brand Name | WINLEY | Place of Origin | CHINA |
| High Light | 75 kVA single-phase pole-mounted transformer ,pole-mounted transformer for rural distribution ,24940GrdY/14400V to 120/240V transformer | ||
This 75 kVA single-phase pole-mounted distribution transformer converts 24940GrdY/14400V primary voltage to 120/240V secondary voltage, built to ANSI C57.12.20 and DOE 2016 standards. Designed with heavy-duty hanger brackets for overhead pole installation, it delivers dependable step-down power distribution for rural grids, residential neighborhoods, and commercial utility networks.
Engineered with 100% copper windings and an ONAN mineral oil immersion system, the unit ensures high thermal endurance and reliable continuous duty under 65°C temperature rise conditions. Equipped with a factory-integrated 24 kV surge arrester and cutout fuse, it protects grid equipment against overvoltage spikes and line faults, significantly reducing maintenance down-time and operational costs for utility power projects.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Conventional liquid-filled pole-mounted transformer | Model | D11-75/24.94/0.12-0.24 |
| Rated Capacity | 75 kVA | Phase | Single phase |
| Primary Voltage | 24940GrdY/14400V | Secondary Voltage | 120/240V |
| Frequency | 60 Hz | Connection Symbol | Ii0 |
| Cooling Method | ONAN, self-cooled | Temperature Rise | 65°C |
| Insulation Class | Class E, 120°C | HV/LV BIL | 150/30 kV |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Winding Material | Copper | Insulating Liquid | Non-PCB mineral oil |
| Ambient Temperature | Up to 40°C | Installation Elevation | Up to 3,300 ft |
| Dimensions | 28.3 W × 30.4 D × 51.2 H in | Total Mass | 1,200 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| No-Load Loss | 124.5 W | No-Load Current | 0.17% |
| Load Loss at 85°C | 743 W | Short-Circuit Impedance at 85°C | 2.39% |
![]()
Ideal for stepping down 14.4 kV primary utility lines to 120/240V for farmsteads, irrigation systems, and remote utility customers.
Suitable for single-phase residential split-phase power supply requiring reliable split 120V and 240V service.
Provides direct power to light commercial buildings, roadside infrastructure, and pole-mounted equipment.
Supports remote industrial pumping stations, mining outpost facilities, and infrastructure construction setups.
![]()
| Rated Capacity (kVA) | High Voltage (kV) | No Load Loss (W) | On Load Loss (W) | Height (mm) | Depth (mm) | Width (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 15kVA |
34.5/19.92 13.8/7.96 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 294 |
| 25kVA | 80 | 290 | 840 | 740 | 610 | 362 | |
| 37.5kVA | 106 | 360 | 840 | 760 | 610 | 476 | |
| 50kVA | 135 | 500 | 840 | 810 | 610 | 553 | |
| 75kVA | 190 | 650 | 840 | 860 | 610 | 672 | |
| 100kVA | 280 | 1010 | 910 | 1200 | 965 | 714 | |
| 167kVA | 435 | 1530 | 1000 | 1200 | 965 | 913 | |
| 250kVA | 550 | 2230 | 1250 | 1300 | 1430 | 1106 |
A: Winley delivers standard pole-mounted distribution transformers within 30 days after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support, we ensure highly cost-effective and reliable solutions.
A: Yes. We accept OEM and ODM. Winley pole-mounted distribution transformers are available in standard ratings from 15-333 kVA (and maximum capability up to 500kVA), with HV systems up to 34.5 kV. According to customer drawings, we can customize secondary voltage, conventional or CSP design, copper or aluminum windings, low-carbon steel or stainless-steel tanks, tap changers, surge arresters, secondary circuit breakers, meter sockets and custom colors. We also integrate components from brands such as Qualitrol and Eaton Cooper.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E543292, designed strictly in compliance with ANSI/IEEE, CSA, DOE, NEMA and IEC 60076 to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, UL/cUL certs, DOE 2016 docs and accessory manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.
A: Yes. Winley matches existing nameplates, utility specifications, mounting dimensions and protection configurations for replacement projects.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...
Get in touch with us
Leave a Message, we will call you back quickly!