| Supply Ability | 500set/month |
| Type | Single-phase Pole-mounted Overhead Distribution Transformer |
| Cooling Class | ONAN |
| Primary Voltage | 24940Y/14400V |
| Packaging Details | Plywood case |
| Delivery Time | 30 days |
| Secondary Configuration | Dual Secondary, X1-X2-X3 and Y1-Y2-Y3 |
| Payment Terms | T/T |
| Operation | Step-down |
| Secondary Voltage | 120/240V |
| Capacity | 5kVA |
| Standard | ANSI/IEEE |
| Certification | UL, cUL |
| Place of Origin | CHINA |
| Model Number | D11-5/24.94/0.24-0.12 |
| Brand Name | WINLEY |
View Detail Information
Explore similar products
167kva Single Phase Pole Mounted Transformer CSP Type oil immersed distribution
Submersible Transformers Underground Vault Installation 25 Kva 13.8KV To 120V
CSA Standard 50kva Pole Mounted Transformer Oil Type 13856V To 120v cUL
15kva Pole Mount Distribution Single Phase Transformer Oil Immersed 4160v To
Product Specification
| Supply Ability | 500set/month | Type | Single-phase Pole-mounted Overhead Distribution Transformer |
| Cooling Class | ONAN | Primary Voltage | 24940Y/14400V |
| Packaging Details | Plywood case | Delivery Time | 30 days |
| Secondary Configuration | Dual Secondary, X1-X2-X3 and Y1-Y2-Y3 | Payment Terms | T/T |
| Operation | Step-down | Secondary Voltage | 120/240V |
| Capacity | 5kVA | Standard | ANSI/IEEE |
| Certification | UL, cUL | Place of Origin | CHINA |
| Model Number | D11-5/24.94/0.24-0.12 | Brand Name | WINLEY |
| High Light | 5kVA pole mounted transformer ,dual-secondary single phase transformer ,DOE efficiency transformer 120/240V | ||
This 5kVA single-phase pole-mounted transformer is configured for a 24.94kV grounded-wye distribution system, using a 14.4kV phase-to-neutral primary input and two separately terminated 120/240V secondary windings. The X and Y secondary groups are brought out through six low-voltage bushings with NEMA 4-hole spade terminals, providing clearly identified connection points for two low-voltage circuit groups.
Built with copper windings, Type II non-PCB mineral oil, ONAN self-cooling and 125kV/30kV BIL, the transformer is designed for outdoor overhead distribution. A five-position no-load tap changer provides primary voltage adjustment from 13.68kV to 15.12kV. The configuration is well suited to utility replacement projects, special rural service points and applications requiring two separately identified 120/240V outputs.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Conventional single-phase pole-mounted distribution transformer | Model | D11-5/24.94/0.24-0.12 |
| Primary Voltage | 24940Y/14400V | Secondary Voltage | 2 × 120/240V |
| Rated Capacity | 5kVA | Phase | Single phase |
| Frequency | 60Hz | BIL | 125kV HV, 30kV LV |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Transformer Configuration | Liquid-filled, conventional pole-mounted | Cooling Method | ONAN |
| Insulating Liquid | Type II non-PCB mineral oil | Winding Material | Copper |
| Core Material | Cold-rolled grain-oriented steel | Insulation Class | Class E, 120°C |
| Temperature Rise | 65°C | Ambient Range | -40°C to +40°C |
| Dimensions | Approx. 18.9 W × 25.1 D × 51.2 H in | Total Mass | 406 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| Short-Circuit Impedance at 85°C | 2.11–2.15% | No-Load Loss | 19.9–22.0W |
| Load Loss at 85°C | 61.5–63.2W | No-Load Current | 0.80–0.89% |
Additional verification included:
Provide H1 and H0 connection points for the 14.4kV phase-to-neutral primary circuit.
Provide separate X1-X2-X3 and Y1-Y2-Y3 terminal groups for the two 120/240V secondary windings.
Allows de-energized primary voltage adjustment from 13.68kV to 15.12kV.
The X2 and Y2 center taps are connected to the transformer grounding arrangement.
Provides a dedicated field connection for grounding the transformer tank.
Relieves excessive internal pressure during abnormal tank pressure buildup.
Provides access for insulating-oil draining, sampling and maintenance.
Allow surge arresters to be installed close to the high-voltage terminals.
Secure the transformer to the utility pole structure.
Provide defined lifting points for transportation and field installation.
Displays electrical ratings, tap positions, terminal connections and unit identification.
![]()
Suitable for replacing existing pole-mounted transformers where voltage ratio, dual-secondary arrangement, polarity, tap range, mounting interface and terminal positions must match an established utility specification.
Configured for service points requiring two separately identified 120/240V secondary groups through X1-X2-X3 and Y1-Y2-Y3 terminals.
Ideal for remote residences, cabins, small farms, barns and agricultural pump systems connected to 24.94kV grounded-wye overhead feeders.
Provides auxiliary power for irrigation controls, livestock equipment, gate automation, outdoor lighting and remote monitoring systems.
| Rated Capacity (kVA) | High Voltage (kV) | No Load Loss (W) | On Load Loss (W) | Height (mm) | Depth (mm) | Width (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 15kVA |
34.5/19.92 13.8/7.96 13.2/7.6 12.47/7.2 or others |
50 | 195 | 840 | 740 | 610 | 294 |
| 25kVA | 80 | 290 | 840 | 740 | 610 | 362 | |
| 37.5kVA | 106 | 360 | 840 | 760 | 610 | 476 | |
| 50kVA | 135 | 500 | 840 | 810 | 610 | 553 | |
| 75kVA | 190 | 650 | 840 | 860 | 610 | 672 | |
| 100kVA | 280 | 1010 | 910 | 1200 | 965 | 714 | |
| 167kVA | 435 | 1530 | 1000 | 1200 | 965 | 913 | |
| 250kVA | 550 | 2230 | 1250 | 1300 | 1430 | 1106 |
A: Winley delivers standard pole-mounted distribution transformers within 30 days after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support, we ensure highly cost-effective and reliable solutions.
A: Yes. We accept OEM and ODM. Winley pole-mounted distribution transformers are available in standard ratings from 15-333 kVA (and maximum capability up to 500kVA), with HV systems up to 34.5 kV. According to customer drawings, we can customize secondary voltage, conventional or CSP design, copper or aluminum windings, low-carbon steel or stainless-steel tanks, tap changers, surge arresters, secondary circuit breakers, meter sockets and custom colors. We also integrate components from brands such as Qualitrol and Eaton Cooper.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E543292, designed strictly in compliance with ANSI/IEEE, CSA, DOE, NEMA and IEC 60076 to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, UL/cUL certs, DOE 2016 docs and accessory manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.
A: Yes. Winley matches existing nameplates, utility specifications, mounting dimensions and protection configurations for replacement projects.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...
Get in touch with us
Leave a Message, we will call you back quickly!