| Primary Voltage | 23kV |
| Payment Terms | T/T |
| Frequency | 60Hz |
| Standard | ANSI/IEEE |
| Secondary Voltage | 4.16Y/2.4kV |
| Delivery Time | 90 days |
| Cooling Class | ONAN |
| Supply Ability | 100set/month |
| Temperature Rise | 55/65K |
| Vector group | Dyn1 |
| Packaging Details | Plywood case |
| Capacity | 10000/11200kVA |
| Model Number | S-10000/23 |
| Certification | ISO CE |
| Place of Origin | CHINA |
| Brand Name | WINLEY |
View Detail Information
Explore similar products
2000kva Substation Power Transformer ONAF Step Down 34.5kv To 480v Electrical
40MVA Substation Power Transformer Oil Immersed High Voltage Step Down 44KV To
34MVA 11kV Substation Transformer for Large Industrial Substations
Multi-Capacity Multi-Voltage 10/11.2/12.5/14 MVA Oil Immersed Substation Power
Product Specification
| Primary Voltage | 23kV | Payment Terms | T/T |
| Frequency | 60Hz | Standard | ANSI/IEEE |
| Secondary Voltage | 4.16Y/2.4kV | Delivery Time | 90 days |
| Cooling Class | ONAN | Supply Ability | 100set/month |
| Temperature Rise | 55/65K | Vector group | Dyn1 |
| Packaging Details | Plywood case | Capacity | 10000/11200kVA |
| Model Number | S-10000/23 | Certification | ISO CE |
| Place of Origin | CHINA | Brand Name | WINLEY |
| High Light | 10MVA oil type power transformer ,23kV to 4.16kV substation transformer ,industrial substation power transformer | ||
Rated at 10000/11200kVA, this oil type substation power transformer steps 23kV primary power down to 4.16Y/2.4kV for outdoor industrial and utility substations. The three-phase unit uses a delta primary, grounded-wye secondary and Dyn1 vector group, with ONAN cooling, copper windings, mineral-oil insulation, and standards identified for the unit as IEEE/ANSI C57.12.00 and IEC60076.
Its 4.16kV secondary is well suited to medium-voltage plant buses and large motor-driven loads, while the off-load ±2×2.5% tap range provides voltage adjustment for system conditions. A 150kV HV BIL and 60kV LV BIL support insulation coordination for 23kV-class outdoor substation service.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Model | S-10000/23 | Rated Capacity | 10000/11200kVA |
| Phase | 3 Phase | Frequency | 60Hz |
| Primary Voltage | 23kV Delta | Secondary Voltage | 4.16Y/2.4kV |
| Vector Group | Dyn1 | Tapping Type | Off-load |
| Tapping Range | ±2×2.5% | HV BIL / LV BIL | 150kV / 60kV |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Oil Type Substation Power Transformer | Insulation Class | Class A |
| Cooling Method | ONAN | Insulating Liquid | Mineral Oil |
| Winding Material | Copper | Core Material | Silicon Steel |
| Temperature Rise | 55/65K | Ambient Temperature | 40°C |
| Service Condition | Outdoor | Altitude | ≤1000m |
| Dimensions | 165×158×98in | Weight | 48000lbs |
| Specification | Data | Specification | Data |
|---|---|---|---|
| No-Load Loss | 9570W | Load Loss at 75°C | 45300W |
| Impedance | 7.0% | No-Load Current | 0.14% |
Ideal for stepping 23kV incoming power down to 4.16kV for medium-voltage plant buses, large motors, pumps and production equipment.
Suitable for outdoor substations supplying 4.16kV medium-voltage distribution to crushers, conveyors, pumps and other high-demand equipment.
Provides centralized 23kV to 4.16kV step-down power for process facilities using medium-voltage motors and plant distribution systems.
Supports outdoor substation applications requiring 10000/11200kVA capacity, ONAN cooling and a grounded 4.16kV secondary system.
![]()
| Specification | Available Options |
|---|---|
| High Voltage (kV) | 4.16 / 12.47 / 13.2 / 13.8 / 24.94 / 34.5 or others |
| Low Voltage (V) | 208/120 / 480/277 / 600 / 12,470 / 13,200 / 13,800 or others |
| Connection Symbol | Dyn1 / Ynyn0 / Dyn11 / Dd0 / Ynd11 or others |
| Short-Circuit Impedance (%) | 2.7 / 3.1 / 4.35 / 5.75 / 6.0 |
| Rated Capacity (kVA) | No-Load Loss (W) | On-Load Loss (W) | Dimensions W × H × D (mm) | Weight (kg) |
|---|---|---|---|---|
| 800 | 980 | 9,350 | 1,060 × 1,500 × 1,780 | 2,050 |
| 1,000 | 1,160 | 11,500 | 1,085 × 1,570 × 1,800 | 2,450 |
| 1,250 | 1,380 | 13,900 | 1,160 × 1,610 × 1,890 | 2,900 |
| 1,600 | 1,660 | 16,600 | 1,190 × 1,630 × 1,950 | 3,400 |
| 2,000 | 2,030 | 18,300 | 1,260 × 1,700 × 2,090 | 4,100 |
| 2,500 | 2,450 | 19,600 | 1,150 × 2,150 × 2,250 | 4,750 |
| 3,000 | 3,240 | 26,500 | 1,900 × 2,600 × 2,150 | 6,500 |
| 5,000 | 4,500 | 27,000 | 2,500 × 2,210 × 3,180 | 9,500 |
| 7,500 | 7,200 | 32,000 | 3,660 × 3,100 × 5,100 | 13,600 |
| 10,000 | 8,500 | 35,500 | 3,830 × 2,640 × 2,216 | 15,800 |
A: Winley provides clear capacity-based lead times after technical approval: 8-10 weeks for transformers below 10 MVA, 10-12 weeks for 10-40 MVA transformers, and 18-20 weeks for 40-100 MVA transformers. We also provide a detailed production schedule and real-time manufacturing photos to help track progress.We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1-3 days with 24/7 support. Leveraging our extensive North American experience in renewable energy, data centers and large industrial projects, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley provides services for substation power transformers up to 100MVA, with HV systems up to 145kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Winley substation transformers are engineered and manufactured in strict accordance with ANSI/IEEE, CSA, NEMA, relevant ASTM standards and IEC 60076.We bring a proven track record across the United States and Canada, supporting critical applications in industrial manufacturing, renewable energy, and power distribution across a range of capacity and voltage requirements.
A: We deliver a complete compliance package: approval drawings, datasheets, nameplate drawings, routine test reports, installation manuals and accessory manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: Yes. Winley Electric provides tailored, fully controllable transportation solutions for large-scale transformer projects to ensure compliant customs clearance and zero-damage delivery. We actively assist in verifying critical logistics factors, including shipping dimensions, total weight, offloading conditions, site accessibility, and lifting/rigging requirements.
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...
Get in touch with us
Leave a Message, we will call you back quickly!