| Supply Ability | 500set/month |
| Standard | ANSI IEEE |
| Operation | Step-down |
| Vector group | YNyn0 |
| Capacity | 1000kVA |
| Delivery Time | 30days |
| Secondary Voltage | 480Y/277V |
| Payment Terms | T/T |
| Cooling Class | KNAN |
| Type | Three Phase Pad Mounted Transformer |
| Primary Voltage | 24940Y/14400V |
| Packaging Details | Plywood case |
| Model Number | ZGS-Z-1000/24.94/0.48 |
| Certification | UL/cUL |
| Brand Name | WINLEY |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
1500 KVA Three Phase Pad Mounted Transformer with 7-Level Off-Circuit Tapping
2500Kva Three Phase Pad Mounted Isolation Oil-Immersed Transformer 480V To 480Y
3000 Kva 3 Phase Pad Mounted Transformer Step-Down 24940V & 12470V UL Certified
2000Kva Three Phase Pad Mounted Transformer Oil Immersed 12.47KV Distribution UL
Product Specification
| Supply Ability | 500set/month | Standard | ANSI IEEE |
| Operation | Step-down | Vector group | YNyn0 |
| Capacity | 1000kVA | Delivery Time | 30days |
| Secondary Voltage | 480Y/277V | Payment Terms | T/T |
| Cooling Class | KNAN | Type | Three Phase Pad Mounted Transformer |
| Primary Voltage | 24940Y/14400V | Packaging Details | Plywood case |
| Model Number | ZGS-Z-1000/24.94/0.48 | Certification | UL/cUL |
| Brand Name | WINLEY | Place of Origin | CHINA |
| High Light | 1000kVA three phase pad mounted transformer ,UL listed distribution transformer 480Y/277V ,24940Y/14400V pad mounted transformer | ||
Engineered to meet the demanding requirements of modern power networks, this 1000 kVA three-phase pad-mounted transformer delivers efficient and reliable voltage conversion from 24940Y/14400V to 480Y/277V. Designed and tested in accordance with ANSI C57.12.34, the rugged, tamper-resistant unit integrates medium-voltage switching, coordinated overcurrent protection, and low-voltage terminations within a compact pad-mounted enclosure—making it a strong choice for outdoor utility distribution, commercial complexes, logistics hubs, and light industrial facilities.
Using biodegradable FR3 non-PCB insulating fluid together with KNAN natural cooling, the transformer supports dependable continuous operation at a 65°C temperature rise without auxiliary forced-air cooling equipment. Its engineered configuration includes a five-position off-circuit tap changer with ±5% adjustment, 125 kV HV BIL, coordinated bayonet and current-limiting fuse protection, and a two-position load-break switch. Together, these features provide flexible voltage matching, enhanced fault protection, convenient high-voltage circuit control, and lasting value for outdoor distribution systems.
| Specification | Data | Specification | Data |
|---|---|---|---|
| Product Type | Three-Phase Pad-Mounted Transformer | Model | ZGS-Z-1000/24.94/0.48 |
| Rated Capacity | 1000 kVA | Phase | Three Phase |
| Primary Voltage | 24940Y/14400V | Secondary Voltage | 480Y/277V |
| Rated Frequency | 60 Hz | Vector Group | YNyn0 |
| Specification | Data | Specification | Data |
|---|---|---|---|
| Cooling Method | KNAN | HV BIL / LV BIL | 125 kV / 30 kV |
| Temperature Rise | 65°C | Winding Material | Copper |
| Dimensions | 71 W × 69 D × 67 H in | Total Weight | 8,095 lb |
| Test Item | Tested Value | Test Item | Tested Value |
|---|---|---|---|
| No-Load Loss | 1128 W | Load Loss at 85°C | 11900 W |
| No-Load Current | 0.21% | Short-Circuit Impedance | 5.39% |
Suitable Applications:
Shopping centers, office buildings, mixed-use developments, hotels, and school campuses.
Why This Transformer Fits:
The 480Y/277V secondary provides a widely used North American distribution voltage for HVAC equipment, pumps, motors, lighting, and building distribution panels. Its compact pad-mounted construction allows the transformer to be installed outdoors, helping preserve valuable indoor electrical space. FR3 natural ester insulating fluid also supports commercial projects that prioritize improved fire performance and lower environmental impact.
Suitable Applications:
Manufacturing plants, assembly workshops, processing facilities, logistics centers, and warehouse distribution hubs.
Why This Transformer Fits:
The 1000 kVA rating provides substantial capacity for motors, production equipment, conveyors, material-handling systems, HVAC equipment, and facility auxiliary loads. Its liquid-filled KNAN design supports dependable outdoor operation without auxiliary forced-air cooling, while the enclosed pad-mounted construction helps protect the high-voltage and low-voltage connection areas from direct access and outdoor exposure.
Suitable Applications:
Municipal underground distribution systems, suburban utility service points, commercial parks, and institutional distribution networks.
Why This Transformer Fits:
Designed and tested in accordance with ANSI C57.12.34, the transformer is configured for North American three-phase pad-mounted distribution. Its 24940Y/14400V primary rating connects to 25 kV-class distribution systems, while the dead-front medium-voltage interfaces, two-position load-break switch, and coordinated bayonet and current-limiting fuse protection support secure outdoor switching, cable connection, and primary fault protection.
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
|---|---|---|---|---|---|---|---|---|---|
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
A: Winley delivers standard three-phase pad-mounted transformers with a 4–6 weeks production time after technical approval. We provide a detailed production schedule and real-time manufacturing photos to help track progress.
A: We offer a flexible MOQ of just 1 unit. Complete inquiries are quoted within 1–2 days with 24/7 support. Leveraging our extensive North American project experience, we ensure highly cost-effective and reliable solutions.
A: Yes, We accept OEM and ODM. Winley three-phase pad-mounted transformers are available in standard ratings from 45–5000kVA (and maximum capability up to 7000 kVA), with HV systems up to 36 kV. We can customize electrical parameters, structure, fluid, protection, switches, gauges, tank and paint according to customer drawings, with the capability to integrate components from brands like Qualitrol, Eaton Cooper, and MR.
A: Yes. Our full range of products are UL/cUL-certified under UL File No. E536138, designed strictly in compliance with ANSI/IEEE, CSA, DOE, and NEMA requirements to meet grid connection and regulatory standards.
A: We deliver a complete compliance package: approval drawings, datasheets, routine test reports, UL/cUL certs, DOE 2016 docs, and operation manuals. We also back your project with lifetime documentation support.
A: Winley ensures quality through 4 annual unannounced UL audits and strict ISO 9001 process management with dedicated QC oversight. Prior to delivery, every unit undergoes comprehensive routine testing, including Winding Resistance, Turns Ratio, Polarity and Phase Relation, and No-Load Loss and Excitation Current tests. We also fully support Factory Acceptance Testing (FAT) and third-party inspections (SGS).
A: 24 months from B/L. During the warranty period, If there are any accessory problems, just provide photos of damaged accessory, then we will provide free service. According to the number of products, we will provide easily damaged accessories for free. We can also provide technical support if you need.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions ...
Get in touch with us