| Primary Voltage | 4.16kV |
| Delivery Time | 90days |
| Type | Substation Power Transformer |
| Vector group | Dyn1yn1 |
| Operation | Step-down |
| Capacity | 1500kVA |
| Supply Ability | 100set/month |
| Standard | ANSI C57.12.00 |
| Payment Terms | T/T |
| Secondary Voltage | 480Y/277 V |
| Packaging Details | Plywood case |
| Cooling Class | KNAN |
| Brand Name | WINLEY |
| Model Number | S-1500/4.16/0.48 |
| Certification | ANSI/IEEE |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
2000kva Substation Power Transformer ONAF Step Down 34.5kv To 480v Electrical
40MVA Substation Power Transformer Oil Immersed High Voltage Step Down 44KV To
1000 KVA 3 Phase Power Distribution Substation Transformer 7200V To 480V IEEE
6500Kva Substation Power Transformer
Product Specification
| Primary Voltage | 4.16kV | Delivery Time | 90days |
| Type | Substation Power Transformer | Vector group | Dyn1yn1 |
| Operation | Step-down | Capacity | 1500kVA |
| Supply Ability | 100set/month | Standard | ANSI C57.12.00 |
| Payment Terms | T/T | Secondary Voltage | 480Y/277 V |
| Packaging Details | Plywood case | Cooling Class | KNAN |
| Brand Name | WINLEY | Model Number | S-1500/4.16/0.48 |
| Certification | ANSI/IEEE | Place of Origin | CHINA |
| High Light | 1500kVA substation power transformer ,step down transformer 4.16kV to 480Y-277V ,ANSI IEEE standards power transformer | ||
| Item | Specification |
|---|---|
| Tranformer Type | Substation Power Transformer |
| Rated Capacity | 1500 kVA |
| Phase | 3 |
| Frequency | 60 Hz |
| Primary Voltage | 4.16 kV |
| Secondary Voltage | 480Y/277 V |
| Vector Group | Dyn1yn1 |
| Impedance | 5.46% |
| HV BIL / LV BIL | 60 kV / 30 kV |
| Temperature Rise | 55/65°C |
| Cooling | KNAN |
| No-load Loss | 1663 W |
| Load Loss at 85°C | 15323 W |
| No-load Current | 0.23% |
| Dimensions | 100 × 74 × 65 inch |
| Total Weight | 10789 lbs |
Technical drawings
![]()
| Station-type structure with separated HV and LV connection areas | Provides a clearer wiring layout for field installation, inspection, and maintenance in substations, industrial facilities, and station service systems. |
| Dyn1yn1 vector group with X/Y low-voltage terminal arrangement | Provides a defined secondary-side terminal layout for distribution systems that require grouped LV connections rather than a simple single-secondary output structure. |
| 5-position off-circuit tap changer | Allows primary-side voltage adjustment when the transformer is de-energized, helping match actual site voltage conditions during commissioning or operation. |
| FR3 non-PCB insulating fluid | Used for insulation and cooling in the liquid-immersed transformer system while meeting non-PCB insulating fluid requirements. |
| HV porcelain bushings, 5 kV class, 60 kV BIL | Provides the primary-side medium-voltage connection and insulation level suitable for a 4.16 kV system. |
| LV 4-hole spade terminals, 1.2 kV class, 30 kV BIL | Supports bolted connection to busbars or cable terminals on the 480Y/277 V secondary distribution side. |
| Oil level gauge, temperature gauge, pressure indicator, and pressure relief device | Allows operators to check oil level, temperature, and pressure conditions during routine inspection, while providing basic pressure relief protection. |
| Drain valve and sampling access | Supports insulating fluid sampling, testing, and maintenance during service life. |
![]()
Applications
| Sector | Applications |
|---|---|
| Industrial | Manufacturing plants, process facilities, motor control centers, 4.16 kV to 480 V distribution systems |
| Utility | Service substations, distribution substations, medium-voltage feeder step-down applications |
| Commercial | Large buildings, campuses, hospitals, data centers and facilities requiring 480Y/277 V distribution |
| Infrastructure | Water treatment plants, pumping stations, transportation facilities and public utility power systems |
Substation Transformer Specification
| kVA | HV | LV | Width(mm) | Length(mm) | Height(mm) |
| 315kVA | 11000V | 400V | 800 | 696 | 1336 |
| 500kVA | 27600V | 480GrdY/277V | 1730 | 2300 | 1510 |
| 500kVA | 11000V | 415V | 1700 | 1700 | 1650 |
| 750kVA | 11000V | 433V | 1850 | 1845 | 1465 |
| 1000kVA | 14400V | 415/240V | 1085 | 1860 | 1570 |
| 1200kVA | 13800V | 240V | 2450 | 1850 | 1820 |
| 1500kVA | 24940V | 600V | 1800 | 1880 | 1895 |
| 2000kVA | 7200V | 600GrdY/346 | 1766 | 2680 | 1982 |
| 2000kVA | 44000V | 600V | 1260 | 2090 | 1700 |
| 2500kVA | 24940V | 480GrdY/277V | 2400 | 2200 | 2060 |
| 3000kVA | 11000V | 415V | 1600 | 2330 | 1920 |
| 3000kVA | 22800V | 415/240V | 2130 | 3500 | 1910 |
| 3750kVA | 44000V | 600V | 2240 | 2650 | 2700 |
| 4000kVA | 33kV | 600Y/347 | 2150 | 3250 | 2290 |
| 5000kVA | 34500V | 7200V | 3780 | 1850 | 3450 |
| 5000kVA | 34500V | 4160V | 2799 | 2400 | 2938 |
| 6300kVA | 35000V | 400V | 3520 | 2820 | 3470 |
| 6800kVA | 34500V | 800V | 3400 | 2670 | 3400 |
| 7500kVA | 27600Y | 4160V | 3350 | 3290 | 2270 |
![]()
![]()
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to...