China factories

Chat Now Send Email
China factory - Xiamen Winley Electric Co.,Ltd

Xiamen Winley Electric Co.,Ltd

  • China,Xiamen ,Fujian
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with
China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with

  1. China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with
  2. China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with
  3. China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with
  4. China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with
  5. China 1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with

1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with

  1. MOQ: 1unit
  2. Price: $1000-$100000
  3. Get Latest Price
Secondary Voltage 480Y/277V
Supply Ability 500set/month
Packaging Details Plywood case
Phase Three Phase
Delivery Time 30days
Type Dry type, Cast Resin Transformer
Temperature Rise 100K
Cooling Class AN/AF
Standard IEC60076
Payment Terms T/T
Capacity 1500kVA AN 2100kVA AF
Primary Voltage 13.2kV
Brand Name WINLEY
Certification CE ISO
Model Number SCB10-1500/13.2
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Secondary Voltage 480Y/277V Supply Ability 500set/month
Packaging Details Plywood case Phase Three Phase
Delivery Time 30days Type Dry type, Cast Resin Transformer
Temperature Rise 100K Cooling Class AN/AF
Standard IEC60076 Payment Terms T/T
Capacity 1500kVA AN 2100kVA AF Primary Voltage 13.2kV
Brand Name WINLEY Certification CE ISO
Model Number SCB10-1500/13.2 Place of Origin CHINA
1500kVA AN 2100kVA AF Cast Coil Dry Type Transformer 13.2kV to 480Y/277V with IEC60076 Standard

Best for:

Protected indoor electrical rooms, transformer rooms, data center power rooms, commercial building service rooms, and industrial facility power rooms requiring oil-free 13.2kV to 480Y/277V step-down distribution.


Customizable Specifications:

kVA, primary voltage, secondary voltage, frequency, vector group, enclosure material (e.g. 304 stainless steel), IP requirement, cooling method, tap range, altitude, destination port and required accessories.


Product Overview

This 1500kVA  AN / 2100kVA  AF cast coil dry type transformer is designed for indoor medium-voltage step-down distribution from 13.2kV to 480Y/277V. It is suitable for transformer rooms, electrical rooms, data center power rooms, commercial building service rooms, industrial facility power rooms, and integrated power distribution systems.

With cast resin insulated coils, IP00 open type construction, AN/AF cooling, Dyn11 vector group, and five-position high-voltage tap adjustment, this transformer is built for projects requiring oil-free indoor power distribution and flexible integration into customer electrical rooms, enclosures, or packaged power systems. The 480Y/277V secondary output is suitable for downstream distribution panels, lighting systems, HVAC equipment, auxiliary loads, and facility power systems.



Product Photos 







Main Data


Item Data
Product type Cast coil dry type transformer
Rated capacity 1500kVA OA / 2100kVA FA
Phase 3 Phase
Primary voltage 13,200V
Secondary voltage 480Y/277V
HV tap voltages 13,860 / 13,530 / 13,200 / 12,870 / 12,540V
Frequency 60Hz
Vector group Dyn11
Insulation class Class F
Temperature rise 100K
Cooling method

AN/AF

Climatic class C2
Environmental class E2
Fire class F1
No-load loss 2,650.2W
Load loss 12,708.8W at 120℃
No-load current 0.28%
Impedance 6.01% at 120℃
Dimensions 1780 × 900 × 2103mm
Weight 3430kg


Technical drawings



Standard Features

  • Cast resin windings: Provide an oil-free insulation structure for indoor electrical rooms, building service rooms, equipment cabinets and integrated power systems.

  • F-class insulation with C2 / E2 / F1 rating: Supports indoor dry-type transformer projects where temperature rise, environmental class and fire behavior need to be considered.

  • 1500kVA OA / 2100kVA FA capacity: Provides natural-air and fan-assisted capacity options for electrical room layouts, enclosure integration and load planning.

  • OA/FA cooling system: Natural air cooling with fan-assisted forced air cooling helps support additional heat dissipation when operating under fan-cooled capacity.

  • Temperature control system: Temperature monitoring and fan control arrangement help monitor winding temperature and support cooling operation during service.

  • Five-position high-voltage tap terminals: 13,860V / 13,530V / 13,200V / 12,870V / 12,540V tapping allows primary-side voltage adjustment during commissioning.



Applications

Sector Applications
Coastal or humid indoor projects Medium-voltage step-down distribution for projects where environmental class needs to be considered, with installation inside an electrical room, enclosure or customer-provided cabinet.
Indoor electrical rooms 13.2kV to 480Y/277V transformer installation for controlled electrical rooms, transformer rooms, switchgear rooms and building service areas.
Commercial building power systems Power supply for 480Y/277V distribution panels, lighting systems, HVAC equipment, pumps, elevators and building auxiliary loads.
Data center power rooms Indoor dry type transformer application for 480Y/277V power circuits, cooling equipment, auxiliary systems and electrical room integration.
Industrial equipment systems Step-down power distribution for low-voltage panels, control systems, fans, pumps, compressors and production support loads.
Fire-sensitive indoor areas Oil-free dry type transformer application for buildings or equipment rooms where liquid-filled transformers are not preferred.
Cabinet-integrated power systems Transformer integration for packaged power systems, switchgear lineups, customer-provided enclosures and skid-mounted electrical systems.


Specification

Rated capacity
(KVA)

High Voltage
(KV)

Low
Voltage
(KV)

Connection Symbol

No-Load Loss
(W)

On-Load Loss
(W)

No Load Current
(%)

Weight
(KG)

Dimension 

L*W*H(mm)

 

100




6

6.3

10

10.5

11






0.4





Dyn11
Yyn0

540

1990

 2.4

 520

 1600*1300*2200

315

970

4080

 1.8

 1085

 1800*1350*2200

500

1350

5790

 1.8

 1520

 2000*1400*2200

630

1530

 6840

 1.6

 1820

 2000*1400*2200

1000

2070

 9780

 1.4

 2550

 2450*1450*2200

1250

2380

11500 

 1.4

 2900

 2300*1500*2200

1600

2790

13800

 1.4

 3490

 2400*1550*2200

2000

3240

16300

 1.2

 4220

 2600*1600*2200

2500

3870

 19300

 1.2

 4955

 2600*1600*2200


Production Process





Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2007

  • Total Annual:

    $45M-$60M

  • Employee Number:

    150~210

  • Ecer Certification:

    Verified Supplier

R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to...

+ Read More

Get in touch with us

  • Reach Us
  • Xiamen Winley Electric Co.,Ltd
  • No. 99 Yilan Road,Siming,Xiamen,Fujian,China
  • https://www.winley-electric.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement