| Payment Terms | T/T |
| Supply Ability | 1000set/month |
| Delivery Time | 30days |
| Packaging Details | Plywood case |
| Phase | Three Phase |
| Capacity | 150KVA |
| Primary Voltage | 34500V |
| Secondary Voltage | 208Y/120V |
| Cooling Class | KNAN; Self-Cooled |
| Vector Group | DYN1 |
| Insulation Rating | Class E Insulation - 120°C, 248°F |
| Winding Material | Copper |
| Brand Name | WINLEY |
| Model Number | S-150/35 |
| Certification | UL/cUL,CE,ISO |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
1500 KVA Three Phase Pad Mounted Transformer with 7-Level Off-Circuit Tapping
2500Kva Three Phase Pad Mounted Isolation Oil-Immersed Transformer 480V To 480Y
3000 Kva 3 Phase Pad Mounted Transformer Step-Down 24940V & 12470V UL Certified
2000Kva Three Phase Pad Mounted Transformer Oil Immersed 12.47KV Distribution UL
Product Specification
| Payment Terms | T/T | Supply Ability | 1000set/month |
| Delivery Time | 30days | Packaging Details | Plywood case |
| Phase | Three Phase | Capacity | 150KVA |
| Primary Voltage | 34500V | Secondary Voltage | 208Y/120V |
| Cooling Class | KNAN; Self-Cooled | Vector Group | DYN1 |
| Insulation Rating | Class E Insulation - 120°C, 248°F | Winding Material | Copper |
| Brand Name | WINLEY | Model Number | S-150/35 |
| Certification | UL/cUL,CE,ISO | Place of Origin | CHINA |
| High Light | 34500v Pad Mounted Transformer ,150kva Pad Mounted Transformer ,208y/120v Pad Mounted Transformer | ||
150kva Three Phase Pad Mounted Transformer 34500v To 208y/120v IEEE/ANSI Standard 304 Stainless Steel
WINLEY Electric specializes in the production of three-phase pad-type transformers, which meet the applicable ANSI®/IEEE®/DOE standards, with voltages up to 34.5 kV and rated power up to 5500kVA. The products are exported to North America in large quantities and have rich experience in design, production, and after-sales service.
![]()
product structure
![]()
Standard Features
• 60 Hz operation.
• 65°C average winding rise.
• Radial & loop feed arrangements.
• Dead and live front type of HV terminals.
• HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
• LV BIL 30 – 60 kV.
• Three-point latching of low-voltage door.
• High-voltage door, which can be opened only after
the low-voltage door is opened.
• Rigid steel partition.
• Transformer tank welded from cover to base.
• Permanent nameplate.
• One-inch NPT pipe cap filling provision.
• ANSI tank ground pads.
• One-inch drain valve and sampler.
• Automatic pressure-relief valve (35 SCFM).
• Tap changer with (2) 2.5% full capacity taps above
and below nominal.
• One 10”x18” (or 14”x25”) hand hole in transformer
tank cover.
• Painted olive-green color (Munsell 7GY 3.29/1.5).
• Designed, manufactured and tested in accordance
with the latest ANSI standards
Main data
| Transformer Type | Pad Mounted, Compartmental-Type |
| Phase | Three Phase |
| Capacity | 150 KVA |
| Vector Group | DYN1 |
| Primary Voltage | 34500V |
| Primary Voltage Class | 35 kV Class |
| Primary BIL | 150 KV |
| Secondary Voltage | 208Y/120 |
| Secondary Voltage Class | 1.2 kV Class |
| Frequency | 60 Hz |
| Temperature Rise | 65°C |
| Insulation Rating | Class E Insulation - 120°C, 248°F |
| Cooling Class | KNAN; Self-Cooled |
| Efficiency Standard(s) | Meets DOE 2016 Standards, Meets CSA Standards Meets ANSI/IEEE Standards |
| K-Factor Rating (Harmonic Mitigation) | K-1 (Standard) |
| Insulation Fluid | Biodegradable Natural Vegetable Oil Ester Insulating Fluid - Non-PCB Fluid |
| Fluid (Oil) Capacity* | 108 Gallons |
| Winding Material | Copper |
| Ambient Temperature Rating | 40°C |
| Ambient Operating Temperature Range | -40°C to +40°C (-50°F to +104°F) |
| Sound Level | 55 dBA |
| Elevation (Altitude) | 3300ft (1000 meters) Above Sea Level |
| Core Material | Grain Oriented Steel |
| Tank Material | 304 Stainless Steel |
| Efficiency % | 99.16% |
| Based on transformer operating at 50% of nameplate base kVA. | |
| Load Losses Based on 85°C Reference Temp. | |
| No Load Loss (in watts) | +/- 320W |
| Full Load Loss (in watts) at 100% | +/- 1,600W |
| Total Load Loss (in watts) at 100% | +/- 1,920W |
Technical drawings
![]()
Specification
| Three Phase Pad Mounted Transformer | ||||
| Rated Power (KVA) | High Voltage (KV) | Low Voltage (V) | Loss (W) | |
| No-load Loss (W) | On-load Loss (W) | |||
| 75KVA | 24.94/14.4kV 12.47/7.2kV 34.5KV/ 19.92KV/ 13.8KV/ 13.2KV/ or others | 120/240V 480Y/ 277V 600Y/ 347V | 180 | 1250 |
| 112.5KVA | 200 | 1500 | ||
| 150KVA | 280 | 2200 | ||
| 225KVA | 400 | 3050 | ||
| 300KVA | 480 | 3650 | ||
| 500KVA | 680 | 5100 | ||
| 750KVA | 980 | 7500 | ||
| 1000KVA | 1150 | 10300 | ||
| 1500KVA | 1640 | 14500 | ||
| 2000KVA | 2160 | 20645 | ||
| 2500KVA | 2680 | 23786 | ||
| 3000KVA | 3300 | 25300 | ||
| 3750KVA | 4125 | 27875 | ||
| 5000KVA | 5200 | 30000 | ||
Production process
![]()
![]()
![]()
FAQ
1. Q: Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.
2. Q: What is the lead time?
A: Mass production time 15-25 days.
3. Q: How long is the warranty?
A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.
4. Q: Is OEM/ODM available?
A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.
Customized services:
a. Customized color and special function.
b. Customized box.
c. Print customer's logo.
d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.
5. Q: How to control the products quality?
A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to...
Get in touch with us
Leave a Message, we will call you back quickly!