| Payment Terms | T/T |
| Supply Ability | 1000set/month |
| Delivery Time | 30days |
| Packaging Details | Plywood case |
| Type | Pad Mounted,Radial Feed |
| Capacity | 500KVA |
| Primary Voltage | 34500GrdY/19920 |
| secondary Voltage | 208Y/120 |
| Frequency | 60 Hz |
| Insulation Rating | Class E Insulation |
| Standard | DOE 2016, CSA , ANSI,IEEE |
| UL/cUL Certification | UL-US-2431836-0, UL-CA-2423202-0 |
| Brand Name | WINLEY |
| Model Number | ZGS-500/34.5 |
| Certification | UL/cUL,CE,ISO |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
500Kva 3 Phase Pad Mounted Transformer Used Residential 34.5KV To 208V UL
1500 KVA Three Phase Pad Mounted Transformer with 7-Level Off-Circuit Tapping
2500Kva Three Phase Pad Mounted Isolation Oil-Immersed Transformer 480V To 480Y
3000 Kva 3 Phase Pad Mounted Transformer Step-Down 24940V & 12470V UL Certified
Product Specification
| Payment Terms | T/T | Supply Ability | 1000set/month |
| Delivery Time | 30days | Packaging Details | Plywood case |
| Type | Pad Mounted,Radial Feed | Capacity | 500KVA |
| Primary Voltage | 34500GrdY/19920 | secondary Voltage | 208Y/120 |
| Frequency | 60 Hz | Insulation Rating | Class E Insulation |
| Standard | DOE 2016, CSA , ANSI,IEEE | UL/cUL Certification | UL-US-2431836-0, UL-CA-2423202-0 |
| Brand Name | WINLEY | Model Number | ZGS-500/34.5 |
| Certification | UL/cUL,CE,ISO | Place of Origin | CHINA |
| High Light | 3 Phase Pad Mounted Transformer ,UL Certified Pad Mounted Transformer ,500Kva Pad Mounted Transformer | ||
UL Certified 3 Phase Pad Mounted Transformer Oil Immersed 500Kva 34.5KV to 208Y Dead Front Loop Feed
Summarization
The three phase pad mounted transformer immerses the load switch and fuse on the high voltage side of the transformer with the core and windings of the transformer in the same oil tank, has the advantages of advanced structure, reliable performance, energy saving and consumption reduction, flexible use, strong adaptability, and economical advantages.
![]()
![]()
Why choose us
Main data
| Phase | Three Phase |
| Capacity | 500 KVA |
| Vector Group | YnYn0 |
| Primary Voltage | 34500GrdY/19920 |
| Primary Voltage Class | 35 kV Class |
| Primary BIL | 150 KV |
| Secondary Voltage | 208Y/120 |
| Frequency | 60 Hz |
| Temperature Rise | 65°C |
| Insulation Rating | Class E Insulation - 120°C, 248°F |
| Cooling Class | KNAN; Self-Cooled |
| Winding Material | Copper |
| Enclosure Rating | NEMA 3R Weatherproof Wiring Cabinet, Sealed Tank |
| Efficiency % | 99.10% |
| No Load Loss (in watts) | +/- 695W |
| Full Load Loss (in watts) at 100% | +/- 4,950W |
Standard Features
• 60 Hz operation.
• 65°C average winding rise.
• Radial & loop feed arrangements.
• Dead and live front type of HV terminals.
• HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
• LV BIL 30 – 60 kV.
• Three-point latching of low-voltage door.
• High-voltage door, which can be opened only after
the low-voltage door is opened.
• Rigid steel partition.
• Transformer tank welded from cover to base.
• Permanent nameplate.
• One-inch NPT pipe cap filling provision.
• ANSI tank ground pads.
• One-inch drain valve and sampler.
• Automatic pressure-relief valve (35 SCFM).
• Tap changer with (2) 2.5% full capacity taps aboveand below nominal.
• One 10”x18” (or 14”x25”) hand hole in transformertank cover.
• Painted olive-green color (Munsell 7GY 3.29/1.5).
• Designed, manufactured and tested in accordancewith the latest ANSI standards
![]()
Performance
Technical drawings
![]()
Specification
| Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
No-load Loss (W) |
On-load Loss (W) |
Height (mm) |
Depth (mm) |
Width (mm) |
Weight (kg) |
Weight (Lbs) |
| 75KVA | 34.5KV 4.160KV 12.47KV 13.2KV 13.8KV 24940GrdY/14400 1247Grdy/7200 4160GrdY/2400 or others |
277V 347V 480V 600V 120/240V 208GrdY/120 415GrdY/240 480GrdY/277 600Y/347 |
180 | 1250 | 1430 | 910 | 1930 | 645 | 1422 |
| 150KVA | 280 | 2200 | 1530 | 980 | 1510 | 989 | 2180 | ||
| 300KVA | 480 | 3650 | 1680 | 1080 | 1660 | 1415 | 3119 | ||
| 500KVA | 680 | 5100 | 1790 | 1160 | 1810 | 1905 | 4200 | ||
| 750KVA | 980 | 7500 | 2030 | 1300 | 2030 | 2755 | 6074 | ||
| 1000KVA | 1150 | 10300 | 1854 | 1549 | 1651 | 3235 | 7132 | ||
| 1500KVA | 1640 | 14500 | 2150 | 1570 | 2210 | 5835 | 12864 | ||
| 2000KVA | 2160 | 20645 | 2220 | 1600 | 2380 | 6430 | 14175 | ||
| 2500KVA | 2680 | 23786 | 2330 | 1650 | 3070 | 8865 | 19544 | ||
| 3000KVA | 3300 | 30300 | 2460 | 1850 | 3260 | 11300 | 24912 | ||
| 3735KVA | 4125 | 37875 | 2680 | 2060 | 4080 | 14400 | 31746 |
Factory Tests
Production process
![]()
![]()
![]()
FAQ
1. Q: Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.
2. Q: What is the lead time?
A: Mass production time 15-25 days.
3. Q: How long is the warranty?
A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.
4. Q: Is OEM/ODM available?
A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.
Customized services:
a. Customized color and special function.
b. Customized box.
c. Print customer's logo.
d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.
5. Q: How to control the products quality?
A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$45M-$60M
Employee Number:
150~210
Ecer Certification:
Verified Supplier
R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to... R&D and production capabilities Winley Electric boasts a team of dozens of experienced senior engineers who are well-versed in transformer standards of different countries including ANSI, IEEE, CSA, DOE2016, NEMA and IEC60076, and who can tailor cost-effective transformer solutions according to...
Get in touch with us
Leave a Message, we will call you back quickly!