China Dura Substitute Non Sutured Tissue Regeneration
China Dura Substitute Non Sutured Tissue Regeneration

  1. China Dura Substitute Non Sutured Tissue Regeneration
  2. China Dura Substitute Non Sutured Tissue Regeneration

Dura Substitute Non Sutured Tissue Regeneration

  1. MOQ: 5 pieces
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 5,000 pieces per month
Delivery Time After receiving the payment, we will send the express within 7 working days
Absorbability Good degradation performance, (passive degradation)
Adhesion Good adhesion to surrounding tissue
Sterility Sterile
Material New natural biomaterials with high biocompatibility and regeneration induction function were developed from animal tissues
Shape Rectangle
Ease Of Use Easy to handle and shape
Strength Good elasticity, High strength
Compatibility Excellent biocompatibility, complete antigen removal, also applicable to highly sensitive populations
Size Various sizes available
Biocompatibility High bionics;Tissue regeneration can be induced in situ after implantation.
Model Number Non-sutured Type
Certification ISO:9001/ISO:13485
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 5,000 pieces per month
Delivery Time After receiving the payment, we will send the express within 7 working days Absorbability Good degradation performance, (passive degradation)
Adhesion Good adhesion to surrounding tissue Sterility Sterile
Material New natural biomaterials with high biocompatibility and regeneration induction function were developed from animal tissues Shape Rectangle
Ease Of Use Easy to handle and shape Strength Good elasticity, High strength
Compatibility Excellent biocompatibility, complete antigen removal, also applicable to highly sensitive populations Size Various sizes available
Biocompatibility High bionics;Tissue regeneration can be induced in situ after implantation. Model Number Non-sutured Type
Certification ISO:9001/ISO:13485 Place of Origin China
High Light Dura Substitute Non suturedDura Substitute Tissue regenerationNon sutured dura patch

Quick Detail:

Indications Brain/spine tumors
  Craniocerebral/spine trauma
  Cerebrovascular disease
  Congenital disease
  Other dura/spinal membranes need to be replaced and strengthened
Specification Various specifications
With packing weight 200g
Warranty 3 years
Classification Class III
Package Sterile Packaging
Place of Origin: China
Product Type Sutureable type / Non-sutured type
Certification ISO:9001/ISO13485
MOQ 5 pieces
Price: Negotiable
Packaging Details Original packaging + carton
Payment Terms: Bank transfer
Supply Ability: 5,000 pieces per month
Delivery Time: After receiving the payment, we will send the express within 7 working days
Shipping FEDEX or Designate
Type Non-sutured type
Specifications: 40mm×50mm ,70mm×90mm,100mm×120mm
Core Technology Unique collagen extraction technology and product forming technology.High purity type I collagen
Notices Do not use if the package is damaged.
  Carefully open the outer package along a small incision, take out the inner package aseptically,and place it directly in a sterilized environment.
  During the operation, the ""smooth side"" should be attached to the brain tissue, and the ""rough side"" should be facing the outside.
  Use conventional methods to suture or paste on the dura (spinal) membrane defect."
  No second use
Contraindications It should be used with caution in patients with a history of allergy to bovine extract materials, and in patients with infected areas or inflammation. The product has not been tested on pregnant women.
Usage

1. Do not squeeze or fold the product. Cut to any shape using sterile technique while dry.

2. After sufficient hemostasis, the smooth surface of the collagen membrane of the product (the side with the logo is the smooth surface) should be oriented towards the defective tissue by aseptic technique in a dry state.

3. The periphery of the product should be 1.5-2cm larger than the defect part, so that the product can fully cover the defect part.

 

Using patent and independent technology, a large class of new natural biomaterials with high biocompatibility and regeneration induction function were developed from animal tissues.

has the following advantages:

 

1. High bionics;

2. Excellent biocompatibility, complete antigen removal, also applicable to highly sensitive populations;

3. De-residual toxicity;

4. Good mechanical compliance, can perfectly fit human tissue;

5. Good elasticity, high strength, safe repair;

6. Good degradation performance, (passive degradation), faster auto-chemical process;

7. Tissue regeneration can be induced in situ after implantation.

8. Applicable for all neurosurgery with dura damage

9. Product type:
                       

                         Non-sutured type Dura Substitute


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2017

  • Total Annual:

    2000000-4000000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

Sichuan Aoshi Yicheng Technology Co., Ltd. is a professional and reliable neurosurgery implant material,medical wound repair materials production and sales company.   We provide customers with high-quality and cost-effective products, and have gained their recognition and trust. Some pro... Sichuan Aoshi Yicheng Technology Co., Ltd. is a professional and reliable neurosurgery implant material,medical wound repair materials production and sales company.   We provide customers with high-quality and cost-effective products, and have gained their recognition and trust. Some pro...

+ Read More

Get in touch with us

  • Reach Us
  • Sichuan Aoshi Yicheng Technology Co., Ltd.
  • Building 3, No. 466 Huizhan Avenue, Xindu District, Chengdu City, Sichuan Province, China
  • https://www.woundneuro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement