DC24V Ultraviolet Flame Detector

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 1000PCS/Month
Delivery Time 7 Working days
Packaging Details 360*250*460mm/Carton
Type Ultroviolet Flame Detector
Operating Voltage Range 12 to 28 VDC Volts
Spectrum 180~290nm
Protection Rating IP21
Relay Contact Load 1A@DC24V
Detection Sensitivity Level 1 25m
Detection Angle 120degree
Alarm Current ≤30 mA
Brand Name XHA
Model Number XHARS602
Certification CCC
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 1000PCS/Month
Delivery Time 7 Working days Packaging Details 360*250*460mm/Carton
Type Ultroviolet Flame Detector Operating Voltage Range 12 to 28 VDC Volts
Spectrum 180~290nm Protection Rating IP21
Relay Contact Load 1A@DC24V Detection Sensitivity Level 1 25m
Detection Angle 120degree Alarm Current ≤30 mA
Brand Name XHA Model Number XHARS602
Certification CCC Place of Origin China
High Light DC24V Ultraviolet Flame Detector ,IP21 Ultraviolet Flame Detector ,IP21 UV Flame Detector

DC24V Ultraviolet Flame Detector With Relay Output And Detection For Fire Alarm System




Introduction
 

The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive
liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm


Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g

 Ultroviolet Flame Detector with Relay Output for Fire Alarm System

Installation
 
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall or Ceiling Products.
1. Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
3. To attach product to mounting base.
4. Secure product by tightening the two mounting screws in the front of the product housing.
5. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
6. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
7. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.

WARNIING:
Not to install flame detector near the below subjects:
1. Halogen lamp, Electric discharge lamp, ultraviolet ray lamp.
2. Welding spark, Electric spark
3. Heavy current magnetic field, thunder discharge.
4. Direct sunlight.
5.Ultra violet radiation subjects
The UV flame detector can not detect the following:
1. The flame behind the glass or transparent resin.
2. Lighted cigarette.
3. Burning charcoal and coal cakes.
4. Burning material without flame.

Application in Conventional Fire Alarm system

Ultroviolet Flame Detector with Relay Output for Fire Alarm SystemUltroviolet Flame Detector with Relay Output for Fire Alarm System

Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement