China Addressable Fire Detection And Fire Alarm System For Commercial / Industrial
China Addressable Fire Detection And Fire Alarm System For Commercial / Industrial

  1. China Addressable Fire Detection And Fire Alarm System For Commercial / Industrial
  2. China Addressable Fire Detection And Fire Alarm System For Commercial / Industrial

Addressable Fire Detection And Fire Alarm System For Commercial / Industrial

  1. MOQ: 1PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union
Supply Ability 500pcs/month
Delivery Time 7 Working days
Packaging Details 1PCS/Carton
Type Intelligent Smoke Alarm System
Backup Battery 12V 2.3 Ah
Main Power AC 90-240V, 50/60Hz
Capacity 254points/loop
Number Of Detectors 1 loop
Operating Temperature -10°C to 50°C
Wiring Mode Non-Polarity 2 Wired
Humidity Range 10% to 95% (non-condensing)
Alarm Output Relay Output
Brand Name XHA
Model Number CA100
Certification CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union Supply Ability 500pcs/month
Delivery Time 7 Working days Packaging Details 1PCS/Carton
Type Intelligent Smoke Alarm System Backup Battery 12V 2.3 Ah
Main Power AC 90-240V, 50/60Hz Capacity 254points/loop
Number Of Detectors 1 loop Operating Temperature -10°C to 50°C
Wiring Mode Non-Polarity 2 Wired Humidity Range 10% to 95% (non-condensing)
Alarm Output Relay Output Brand Name XHA
Model Number CA100 Certification CE
Place of Origin China
High Light Addressable Fire Detection And Fire Alarm System ,Addressable Fire Detection And Alarm System ,Addressable Fire Detection System

Addressable Fire Alarm System Fire Detection For Commercial And Industrial Facilities

 

 





Introduction

 

An addressable fire alarm system is a type of fire detection and alarm system that uses addressable devices, such as smoke detectors, heat detectors, and manual pull stations, to communicate their status and location back to a central control panel. Each addressable device is assigned a unique address or identifier, allowing the control panel to precisely pinpoint the location of a triggered alarm.

 

 


Parameters
 
Product Name Addressable Fire Alarm Control Panel Capacity 254points/loop
Capacity Maximum 1 loops Main power supply AC220V± 15%, 2.5A, 50HZ. 
Battery power supply DC 24V (1 sealed batteries: 1*12V*2.3Ah) Loop Bus wired Non-polarity 2 wired.
LCD Small size, easy Installation
 
 Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.



Main Functions

 

Addressable Devices: Unlike conventional fire alarm systems that use zone-based detection, addressable systems have individual devices with unique addresses. This allows the control panel to identify the exact location of an alarm or trouble condition.


Central Control Panel: The heart of the system is the addressable fire alarm control panel. It continuously monitors the status of all connected devices and can quickly identify the triggering device during an alarm.


Zoning and Mapping: The control panel can be programmed to associate addressable devices with specific zones or floor plans. This provides clear visual indication of alarm locations on the control panel's display.


Increased Flexibility: Addressable systems offer more flexibility in system design and expansion. New devices can be easily added or relocated without rewiring the entire system.


Advanced Diagnostics: The control panel can provide detailed diagnostic information, such as device status, maintenance requirements, and wiring faults, to aid in system troubleshooting and maintenance.


Integrated Systems: Addressable fire alarm systems can be integrated with other building systems, such as HVAC, access control, and security, for coordinated emergency response and control.


Scalability: Addressable systems can accommodate a large number of devices, making them suitable for small to large-scale commercial, industrial, and multi-story buildings.

 


 




Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide special technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2001

  • Total Annual:

    4300000-7140000

  • Employee Number:

    40~50

  • Ecer Certification:

    Verified Supplier

We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Xinhe'an Technology Co., Ltd.
  • 406,Jude Building,Zhengfeng South Road,Fuyong Street,Bao'An District, Shenzhen City, Guangdong Province. China,518103
  • https://www.xhafiresafety.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement