Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"2 Zone Conventional Fire Alarm Panel Wall Mounted For Fire Fighting System","imgUrl":"https:\/\/img.chinax.com\/nimg\/00\/fb\/93b0e42eb0b23999e21a56cf919c-200x200-1\/2_zone_conventional_fire_alarm_panel_wall_mounted_for_fire_fighting_system.jpg","attrs":{"Brand Name":"XHA","Model Number":"XHA1002","Certification":"CE","Place of Origin":"China"}}
{"title":"2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm","imgUrl":"https:\/\/img.chinax.com\/nimg\/09\/fd\/c95a260cfe1763b9c975c349d1be-200x200-1\/2_wire_conventional_fire_alarm_system_wall_mount_with_sound_and_light_alarm.jpg","attrs":{"Brand Name":"XHA","Place of Origin":"China","Certification":"CE","Minimum Order Quantity":"1"}}
{"title":"AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke","imgUrl":"https:\/\/img.chinax.com\/nimg\/55\/0c\/9ee45063fc08cdde1ab25a99d029-200x200-1\/ac90_270v_fire_alarm_control_panel_4_zone_8_zone_16_zone_with_conventional_smoke_alarm.jpg","attrs":{"Brand Name":"XHA","Place of Origin":"China","Certification":"CE","Minimum Order Quantity":"1"}}
{"title":"Wall \/ Ceiling Mount Conventional Fire Alarm System With Smoke \/ Heat Detector","imgUrl":"https:\/\/img.chinax.com\/nimg\/ca\/db\/c77efecbdd85a847198a7f178b98-200x200-1\/wall_2f_ceiling_mount_conventional_fire_alarm_system_with_smoke_2f_heat_detector.jpg","attrs":{"Brand Name":"XHA","Place of Origin":"China","Certification":"CE","Minimum Order Quantity":"1"}}
{"title":"2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm","imgUrl":"https:\/\/img.chinax.com\/nimg\/bd\/9e\/34f4f3e74e6d3bfcd5a4934f6d81-200x200-1\/2_wire_fixed_rate_of_rise_heat_detector_ror_for_conventional_safety_fire_alarm_system.jpg","attrs":{"Brand Name":"XHA","Model Number":"YT105","Certification":"CE","Place of Origin":"China"}}
{"title":"4 Zone 8 Zone 16 Zone Conventional Fire Alarm System For Industrial Buildings","imgUrl":"https:\/\/img.chinax.com\/nimg\/8b\/88\/fb5e633fdb7e90efba2f2b344593-200x200-1\/4_zone_8_zone_16_zone_conventional_fire_alarm_system_for_industrial_buildings.jpg","attrs":{"Brand Name":"XHA","Place of Origin":"China","Certification":"CE","Minimum Order Quantity":"1"}}
{"title":"Conventional 2 Zone Fire Alarm Panel","imgUrl":"https:\/\/img.chinax.com\/nimg\/55\/0c\/9ee45063fc08cdde1ab25a99d029-200x200-1\/conventional_2_zone_fire_alarm_panel.jpg","attrs":{"Brand Name":"XHA","Model Number":"XHA1002","Certification":"CE","Place of Origin":"China"}}
Conventional Fire Alarm Panel 2 Zone For Fire Fighting System
Introduction
The fire alarm control panels (2 Zone,4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a
leading edge conventional fire alarm system along with the simple operation and efficient installation methods
demanded by both installers and building users.
The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top
cable entries.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical,
ionization, photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides
assurance that the control panel, smoke detectors, interface devices and the ancillary components are all fully
compatible with one another and that the full range of system functionality is supported by each device.
This series of panels are basically the same in application and operation, their differences are shown in Table 1. PANEL
will be described as the example in the following sections.
Product Features
4,8,16 Class B Initiating Device Circuits (lDCs). . All zones accept conventional detectors and any normally open contact device. . Four Class B Notification Appliance Circuits (NACs). . One Form-A Alarm Relay. . One Form-A Fault Relay. . One Form-A Supervisory Relay . 3.0 amps ofsystem power. . Max 30 conventional detectors in one zone. . Auto/Manual mode setting enable. . Each Zone can be disabled. . Sound output can be disabled. . Manual active sound output enabled. . Able to report short and broken circuit of detection zones. . Designed with standby batteries and space provision for 1 sealed lead- acid batteries Evacuate,Testing and disable functions. . Remote reset and silence alarm functions . Can conneet max 32 repeater panels by RS485 communication port . Dimensions :14.57"(37 cm) long X 17.32"(44 cm) high X 3.94"(10cm) . Weight: 6.6kg (without battery)
Specification
Primary AC
120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating
2 Amps @ 24VDC
Maximum Battery Charging Current
0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones
Alarm Zone 2
Normal Initiating Operating Voltage
23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
<50mA
Alarm Current (not include the others)
<150 mA
Short Circuit Initiating Current (per zone)
35mA Maximum
Maximum Initiating Resistance (per zone)
10 ohms
Initiating End-of-Line Resistor
4K7 ohms, 1/2W 5%
Standby Detector Current (per zone)
4mA maximum
Maximum Detector Count (per zone)
30 detectors
Initiating Cabling Type
18AWG Twisted Shielded pair (14 – 18 AWG)
Detector Base Impedance
430 ohms
Notification Appliance Circuits
1 NACs, Special Application
Maximum NAC Current Rating
1 Amp maximum per circuit
NAC Operating Voltage
26VDC Nominal, 30VDC Maximum
NAC End-of-line Resistor
1N4007 Diode
FAULT Relay rating
2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating
2A & 30VAC, resistive
Master alarm panel
Digital & LED display
Slave alarm panel
LED display only
Product range
Conventional Fire Alarm System Addressable fire alarm system Gas Extinguishing control system Beam Detector Standalone smoke detectors and combustable gas detector 4 wire smoke detectors with relay output. 2 wire Conventional smoke and heat detectors Explosion-proof flame detector for fire alarm system
Service
1. OEM &ODM service. 2. Provide technical support and after-sale service. 3. 1 year warranty. 4. Normally 15 working days lead time. 5. Welcome sample order.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Year Established:
2001
Total Annual:
4300000-7140000
Employee Number:
40~50
Ecer Certification:
Verified Supplier
We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...