| Payment Terms | T/T, Western Union |
| Supply Ability | 10000PCS/Month |
| Delivery Time | 3 Working days |
| Packaging Details | 100pcs/carton |
| Apaitplicon | Fire Alarm System |
| Product Type | Restorable Call Point |
| Relay contact rating | 1A/30VDC |
| Working Voltage | 9 to 33 VDC |
| Wired | 2 Wired,Non-polarized |
| Operating Temperature | 0-50 degrees Celsius |
| Name | Resettable Call Point |
| Brand Name | XHA |
| Model Number | XHA8032 |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
2 Wire Conventional Fire Alarm System Wall Mount With Sound And Light Alarm
AC90-270V Fire Alarm Control Panel 4 Zone 8 Zone 16 Zone With Conventional Smoke
Wall / Ceiling Mount Conventional Fire Alarm System With Smoke / Heat Detector
2 Wire Fixed Rate Of Rise Heat Detector ROR For Conventional Safety Fire Alarm
Product Specification
| Payment Terms | T/T, Western Union | Supply Ability | 10000PCS/Month |
| Delivery Time | 3 Working days | Packaging Details | 100pcs/carton |
| Apaitplicon | Fire Alarm System | Product Type | Restorable Call Point |
| Relay contact rating | 1A/30VDC | Working Voltage | 9 to 33 VDC |
| Wired | 2 Wired,Non-polarized | Operating Temperature | 0-50 degrees Celsius |
| Name | Resettable Call Point | Brand Name | XHA |
| Model Number | XHA8032 | Certification | CE |
| Place of Origin | China | ||
| High Light | Safety Device Resettable Call Point ,Resettable Call Point Conventional ,Conventional Manual Pull Station Fire Alarm System | ||
Resettable Call Point For Conventional Fire Detection Fire Safety System
![]()
Introduction
A manual call point, also known as a manual pull station or manual fire alarm is a safety device used in fire alarm systems to allow occupants to manually activate the fire alarm in the event of an emergency. Here's a more detailed introduction to manual call points:
Purpose:
Manual call points are designed to provide a means for building occupants to manually trigger the fire alarm system.
They allow people to alert the fire department and other building occupants of a potential fire or other emergency situation.
Activation:
Manual call points typically have a prominent red housing and a lever, button, or pull-down handle that must be activated to trigger the alarm.
Activating the manual call point, either by pulling the lever, pressing the button, or breaking the glass (if present), sends a signal to the fire alarm control panel to initiate the alarm sequence.
Alarm Activation:
When a manual call point is activated, it triggers the fire alarm system, causing the building's audible and visual alarms (such as sirens, bells, and strobe lights) to be activated.
This alerts building occupants to the emergency and prompts them to evacuate the premises.
Placement:
Manual call points are strategically placed throughout a building, usually near exits and along common pathways, to ensure they are easily accessible to building occupants.
Their placement is typically governed by local fire codes and regulations to ensure adequate coverage and accessibility.
Resetting:
After a manual call point has been activated, it must be reset by a trained professional, such as a fire alarm technician or a firefighter.
Resetting the call point involves restoring the lever, button, or pull-down handle to its original position, which then allows the fire alarm system to be reset.
Parameters
| Product Name | Restorable Call Point | Rated operational voltage | 9 to 33VDC Volts Non-polarized |
| Relay contact rating | 1A/30VDC | Work temperature | -10°C~+50°C |
| Certification | CE | Humidity | ≤95%. |
| Size | 86*89*37mm | Weight | 125 g |
TO RESET
The call point can be reset by a key from alarm return to normal status
![]()
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Company Details
Year Established:
2001
Total Annual:
4300000-7140000
Employee Number:
40~50
Ecer Certification:
Verified Supplier
We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres... We sepecializes in design and manufacture of high quality fire protection solutions for commerical, industrial and domestic applications. we have nearly 20 years experience in the field of fire protection industry.Everlasting desire for innovation drives our company's product development progres...
Get in touch with us
Leave a Message, we will call you back quickly!