Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 1000km per month |
Delivery Time | 10 ays or More |
Packaging Details | Wooden Drum or Steel Drum |
Phase Conductor | Aluminium |
Neutral Conductor | Aluminum Alloy |
Street Lighting | Aluminium |
Insulation | PE |
Rated Voltage | 0.6/1KV |
Application | Overhead Power Line |
No. of Cores | 5 |
Brand Name | HOLD-ONE |
Model Number | |
Certification | IEC 60502 |
Place of Origin | China |
View Detail Information
Explore similar products
Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System
Outdoor Two Core Aerial Bundled Cable , XLPE / PVC Insulation Cable
Custom Aerial Bundled Cable , PE Insulated Cable Aluminium Alloy Conductors
1000V Electrical ABC Aerial Bundled Cables Three Cores PVC Insulated
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000km per month |
Delivery Time | 10 ays or More | Packaging Details | Wooden Drum or Steel Drum |
Phase Conductor | Aluminium | Neutral Conductor | Aluminum Alloy |
Street Lighting | Aluminium | Insulation | PE |
Rated Voltage | 0.6/1KV | Application | Overhead Power Line |
No. of Cores | 5 | Brand Name | HOLD-ONE |
Model Number | Certification | IEC 60502 | |
Place of Origin | China | ||
High Light | aerial electrical cable ,abc power cable |
PE Insulation Five Core Aerial Drop Cable STANDARD NF C 33-209 NFA 2X
Construction
a)Phase - The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
b)Neutral or messenger - The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded c)Street Lighting- The street lighting conductors shall be of H68 condition aluminium conductor and compacted circular stranded..
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
Schedule of technical particulars
Phase conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||
Conductor temperature=75℃ | |||||||||
Messenger conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Street lighting conductor | |||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Completed cable | |||||||||
Approx. overall diameter | mm | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 470 | 560 | 740 | 980 | 1330 | 1580 | 1940 | 2410 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
STANDARD NF C 33-209
NFA 2X
Phases | Neutral/Messenger | ||||||||
Distribution Lines | Pub. Lighting | ||||||||
Cable Type | Number of | Number of | Avarage | Resistance | Conductance | Number of | Avarage | Rated | Resistance |
core | wire | diameter | at 20℃ | at 30℃ | core | diameter | Strength | at 20℃ | |
mm² | mm² | PCS | mm | ohm/km | A | mm² | mm | kN | ohm/km |
2x16 | 2x16 | 7 | 4.6 | 1.91 | 93 | - | - | - | - |
2x35 | 2x35 | 7 | 5.9 | 1.20 | 122 | - | - | - | - |
2x35 | 2x35 | 7 | 6.9 | 0.868 | 129 | - | - | - | - |
2x50 | 2x50 | 7 | 8.1 | 0.641 | 158 | - | - | - | - |
4x16 | 4x16 | 7 | 4.6 | 1.91 | 83 | - | - | - | - |
4x25 | 4x25 | 7 | 5.9 | 1.20 | 111 | - | - | - | - |
4x35 | 4x35 | 7 | 6.9 | 0.868 | 131 | - | - | - | - |
3x25+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | - | 9.6 | 16.0 | 0.63 |
3x25+1x16+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | 1x16 | 9.6 | 16.0 | 0.63 |
3x25+2x16+54.6 | 3x25 | 7 | 5.9 | 1.20 | 112 | 2x16 | 9.6 | 16.0 | 0.63 |
3x35+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | - | 9.6 | 16.0 | 0.63 |
3x35+1x16+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | 1x16 | 9.6 | 16.0 | 0.63 |
3x35+2x16+54.6 | 3x35 | 7 | 6.9 | 0.868 | 138 | 2x16 | 9.6 | 16.0 | 0.63 |
3x50+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | - | 9.6 | 16.0 | 0.63 |
3x50+1x16+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | 1x16 | 9.6 | 16.0 | 0.63 |
3x50+2x16+54.6 | 3x50 | 7 | 8.1 | 0.641 | 168 | 2x16 | 9.6 | 16.0 | 0.63 |
3x70+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | - | 9.6 | 16.0 | 0.63 |
3x70+1x16+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x16 | 9.6 | 16.0 | 0.63 |
3x70+2x16+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x16 | 9.6 | 16.0 | 0.63 |
3x70+1x25+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x25 | 9.6 | 16.0 | 0.63 |
3x70+2x25+54.6 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x25 | 9.6 | 16.0 | 0.50 |
3x70+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | - | 10.2 | 20.6 | 0.50 |
3x70+1x16+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | 1x16 | 10.2 | 20.6 | 0.50 |
3x70+2x16+70 | 3x70 | 12 | 9.7 | 0.443 | 213 | 2x16 | 10.2 | 20.6 | 0.50 |
3x95+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | - | 10.2 | 20.6 | 0.50 |
3x95+1x16+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | 1x16 | 10.2 | 20.6 | 0.50 |
3x95+2x16+70 | 3x95 | 12 | 11.5 | 0.320 | 258 | 2x16 | 10.2 | 20.6 | 0.50 |
3x120+70 | 3x120 | 12 | 12.8 | 0.253 | 300 | - | 10.2 | 20.6 | 0.50 |
3x120+1x16+70 | 3x120 | 19 | 12.8 | 0.253 | 300 | 1x16 | 10.2 | 20.6 | 0.50 |
3x120+2x16+70 | 3x120 | 19 | 12.8 | 0.253 | 300 | 2x16 | 10.2 | 20.6 | 0.50 |
3x150+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | - | 10.2 | 20.6 | 0.50 |
3x150+1x16+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | 1x16 | 10.2 | 20.6 | 0.50 |
3x150+2x16+70 | 3x150 | 19 | 14.5 | 0.206 | 344 | 2x16 | 10.2 | 20.6 | 0.50 |
3x120+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | - | 12.9 | 27.9 | 0.343 |
3x120+1x16+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | 1x16 | 12.9 | 27.9 | 0.343 |
3x120+2x16+95 | 3x120 | 19 | 12.8 | 0.253 | 300 | 2x16 | 12.9 | 27.9 | 0.343 |
3x150+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | - | 12.9 | 27.9 | 0.343 |
3x150+1x16+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | 1x16 | 12.9 | 27.9 | 0.343 |
3x150+2x16+95 | 3x150 | 19 | 14.5 | 0.206 | 344 | 2x16 | 12.9 | 27.9 | 0.343 |
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
8000000-10000000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
Founded in 2000, HOLD-ONE. is a modern large-scale enterprise specializing in R&D and manufacturing of wire and cable. The company has an insulated wire workshop, a low voltage cable workshop, a high voltage cable workshop and cable accessories, and a copper processing workshop. It consists of a... Founded in 2000, HOLD-ONE. is a modern large-scale enterprise specializing in R&D and manufacturing of wire and cable. The company has an insulated wire workshop, a low voltage cable workshop, a high voltage cable workshop and cable accessories, and a copper processing workshop. It consists of a...
Get in touch with us
Leave a Message, we will call you back quickly!