China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC
China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC

  1. China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC
  2. China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC
  3. China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC
  4. China 15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC

15kV Cable Fault Locator Outer Sheath Murray Bridge No Blind Zone and DC

  1. MOQ: 1unit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 3000unit/year
Delivery Time 5-8 work days
Packaging Details wooden packaging
Brand Name XZH TEST
Model Number XHHG521CL
Certification CE/ISO
Place of Origin Xi'an, Shaanxi, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 3000unit/year
Delivery Time 5-8 work days Packaging Details wooden packaging
Brand Name XZH TEST Model Number XHHG521CL
Certification CE/ISO Place of Origin Xi'an, Shaanxi, China
High Light Open-circuit voltage 15kV Cable Fault Locator ,Precise Detection Power Cable Fault Detector ,Outer sleeve failure Cable Fault Tester
XHHG521CL Cable Outer Sheath Fault Tester — Cable Fault Locator

The Cable Outer Sheath Fault Tester is designed on the MURRAY bridge principle and can be used to pinpoint the breakdown points of various wires and cables, as well as defect points that have not yet broken down but have a low insulation-resistance value.

The equipment uses a motorized voltage regulator and an R-type transformer to form a high-voltage constant-current source, with keys to raise and lower the voltage. Its no-load voltage is 15kV, with a high short-circuit current. A high-sensitivity amplifier and a galvanometer provide the balance indication, which together with a proportional potentiometer forms a balanced bridge placed at high potential. The measuring cable is a specially designed two-core high-voltage rubber cable, and the four-terminal resistance measurement method avoids the error introduced by lead resistance. The panel as a whole is at low potential. With one-key operation, the fault distance is calculated automatically once the cable length is entered. The high-voltage source and the bridge are integrated in one portable protective case, so the equipment offers high voltage, light weight, convenient operation and safe use.

Product Features Bridge Part
Adjustable output voltage.
High precision and stability.
A high-sensitivity amplifier and a galvanometer provide the balance indication.
Zero-position protection.
Automatic fault-point testing, while retaining the manual testing function.
Compared with the wave-reflection method, the bridge-balance method has no blind zone, making it suitable for judging short cables and breakdown points near the terminals.
Withstand-Test Part
Automatic over-current, over-voltage and over-heat protection.
Zero-position start protection, for greater safety and reliability.
A unique self-discharge design: as soon as the high-voltage output is cut off, the high voltage itself drops to zero.
Dual pointer meters for current and voltage give an intuitive and clear reading.
Over-current protection switch function.
Recommended Users and Applications

This tester works on the outer sheath (protective layer) of high-voltage and extra-high-voltage cables. Its focus is the sheath withstand test and the location of high-resistance and flashover-type sheath breakdowns on 10kV–500kV single-core and three-core cables, and it is especially suited to:

1. Extra-high-voltage cable engineering and transmission-and-transformation engineering companies

For the outer-sheath handover test after laying 110kV and above XLPE cables and for cross-bonded systems, meeting the GB50150-2006 sheath withstand-test requirements (including the 5kV–15kV, 1-minute DC withstand test on HDPE and PVC sheaths).

2. Operation units of 10kV–500kV single-core and three-core cables

For quickly and accurately finding outer-sheath ground faults and excessive leakage current, and for troubleshooting operating defects such as termite bites, water ingress in grounding boxes, deterioration of existing defect points and moisture penetration in the branched part of the grounding wire.

3. Teams locating high-resistance and flashover-type breakdowns

For linear high-resistance breakdown points that are hard to burn into low resistance (for example at cable intermediate joints), for flashover-type breakdown points where the constant-current source maintains the arc, and for defect points that have not broken down but show low resistance on a megohmmeter — using the bridge-balance method, which has no blind zone.

Especially Suitable For
1.High-resistance breakdown points of laid cables, especially linear high-resistance breakdown points that are difficult to burn into low resistance, such as a linear high-resistance breakdown at a cable intermediate joint.
2.Flashover-type breakdown points: after breakdown the constant-current source can maintain the arc, so a stable current passes through the bridge and the bridge has sufficient sensitivity.
3.Defect points that have not yet broken down but have a low resistance, such as insulation defects that are found to have a low resistance with a megohmmeter but do not break down at operating voltage.
Technical Parameters Bridge Part
Item Specification
No-load voltage ≥15kV
Short-circuit current ≥150mA (when balancing, 5–40mA is recommended)
Positioning ratio accuracy ±(0.2%·L±1) m
Working power Supply: AC 220V (±10%), 50Hz±1Hz; balancing power: 8.4V built-in battery
Withstand-Test Part
Item Specification
Input voltage 220V (±10%), 50Hz (±2Hz)
Output voltage 0–15kVDC, adjustable
Output current 0–150mA
Output capacity 2kVA
FAQ
Q1. What is the XHHG521CL Cable Outer Sheath Fault Tester used for?

It is designed on the MURRAY bridge principle to pinpoint the breakdown points of wires and cables and defect points that have not yet broken down but have a low insulation resistance. For high-voltage and extra-high-voltage cables it finds outer-sheath ground faults and excessive leakage current on 10kV–500kV single-core and three-core cables, and carries out 5kV–15kV, 1-minute DC withstand tests on HDPE and PVC outer sheaths.

Q2. Why is the bridge-balance method used?

Compared with the wave-reflection method, the bridge-balance method has no blind zone, so it is suitable for judging short cables and breakdown points near the terminals, as well as high-resistance breakdown points that are hard to burn into low resistance and flashover-type breakdown points.

Q3. What are the main technical parameters?

Bridge part: no-load voltage ≥15kV; short-circuit current ≥150mA (5–40mA recommended when balancing); positioning ratio accuracy ±(0.2%·L±1) m; weight 35kg; supply AC 220V (±10%), 50Hz±1Hz and an 8.4V built-in balancing battery. Withstand-test part: input 220V (±10%), 50Hz (±2Hz); output 0–15kVDC adjustable; output current 0–150mA; output capacity 2kVA.

Q4. What protection functions does it provide?

It offers zero-position protection on the bridge, and automatic over-current, over-voltage and over-heat protection with zero-position start protection on the withstand-test part, a unique self-discharge design (the high voltage drops to zero as soon as the output is cut off), dual current/voltage pointer meters and an over-current protection switch.

Q5. Does the output voltage meet the relevant standard?

Yes. The output is 15kV and below, which fully meets the cable outer-sheath withstand-test requirements of the Chinese national standard GB50150-2006, including the sheath handover test and preventive test for cross-bonded systems.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

                        Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...                         Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
  • Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
  • https://www.xzhtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement