China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0
China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0

  1. China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0
  2. China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0
  3. China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0
  4. China Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0

Cable Outer Sheath Fault Locator Portable High Voltage Murray Bridge and 0

  1. MOQ: 1unit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 3000unit/year
Delivery Time 5-8 work days
Packaging Details wooden packaging
Brand Name XZH TEST
Model Number XHHG521CL
Certification ISO/CE
Place of Origin Xi'an ShanXi

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 3000unit/year
Delivery Time 5-8 work days Packaging Details wooden packaging
Brand Name XZH TEST Model Number XHHG521CL
Certification ISO/CE Place of Origin Xi'an ShanXi
High Light 50Hz Cable Sheath Fault Locator ,Outer Sleeve Failure Cable Fault Locator ,Rough Measurement Outer Sleeve Fault Detector
XHHG521CL Portable Cable Sheath Fault Tester — Cable Fault Locator

The Cable Outer Sheath Fault Tester is built on the MURRAY bridge principle and is used to locate the breakdown points of wires and cables as well as defect points that have not yet broken down but show a low insulation-resistance value. The high-voltage source and the bridge are integrated in a single portable protective case, so the equipment combines high voltage with light weight, convenient operation and safe use.

Working Principle

The equipment uses a motorized voltage regulator and an R-type transformer to form a high-voltage constant-current source, with keys to raise and lower the voltage. A high-sensitivity amplifier and a galvanometer give the balance indication and, together with a proportional potentiometer, form a balanced bridge placed at high potential. The measuring cable is a specially designed two-core high-voltage rubber cable, and the four-terminal resistance measurement method avoids the error introduced by lead resistance, while the panel as a whole is at low potential. With one-key operation, once the cable length is entered the fault distance is calculated automatically.

Application Background

With the full spread of urban grid renovation, many power supply bureaus, construction parties and design units are working with 110kV and above XLPE cables for the first time. Because of time pressure and inexperience, many cables fail the sheath withstand test (10kV/1min) after laying. Cable outer sheaths mostly use HDPE sheath material that has already passed a DC 25kV/5min withstand test in the factory, with a leakage current as low as tens of μA, so post-laying defects mostly come from external-force damage during laying, including the filling and cover-plate work. After the cable is put into operation, defects usually come from termite bites, water ingress in grounding boxes, deterioration of existing defect points and moisture penetration in the branched part of the grounding wire that lowers the insulation resistance — and when a cable is buried too deep or the surroundings are complex, positioning becomes very difficult and some defect points remain unsolved for years.

Product Features Bridge Part
Adjustable output voltage, with high precision and stability.
A high-sensitivity amplifier and a galvanometer provide the balance indication, together with zero-position protection.
Automatic fault-point testing, while the manual testing function is retained.
Compared with the wave-reflection method, the bridge-balance method has no blind zone, so it suits short cables and breakdown points near the terminals.
Withstand-Test Part
Automatic over-current, over-voltage and over-heat protection.
Zero-position start protection, for greater safety and reliability.
A unique self-discharge design: as soon as the high-voltage output is cut off, the high voltage itself drops to zero.
Dual pointer meters for current and voltage, plus an over-current protection switch.
Recommended Users and Applications

This tester is dedicated to the outer sheath (protective layer) of high-voltage cables: locating sheath breakdowns and low-resistance defects and carrying out sheath withstand tests. It suits site teams that face post-laying sheath problems, and it is especially suited to:

1. Power supply bureaus, construction parties and design units in urban grid renovation

For projects meeting 110kV and above XLPE cables for the first time, where laid cables fail the sheath withstand test (10kV/1min) and the defective points must be found and dealt with.

2. Cable-laying contractors and filling / cover-plate works teams

For locating outer-sheath defect points caused by external-force damage during laying, filling and cover-plate work, using the bridge-balance method that has no blind zone.

3. Cable-joint and grounding-system operation and maintenance teams

For locating linear high-resistance breakdowns at cable intermediate joints, and for troubleshooting reduced insulation resistance caused by termite bites, water ingress in grounding boxes and moisture penetration in the branched part of the grounding wire.

Especially Suitable For
1.High-resistance breakdown points of laid cables, especially linear high-resistance breakdown points that are difficult to burn into low resistance, such as a linear high-resistance breakdown at a cable intermediate joint.
2.Flashover-type breakdown points: after breakdown the constant-current source can maintain the arc, so a stable current passes through the bridge and the bridge has sufficient sensitivity.
3.Defect points that have not yet broken down but have a low resistance, such as insulation defects that show a low resistance on a megohmmeter but do not break down at operating voltage.

The output voltage is 15kV and below, fully meeting the cable outer-sheath withstand-test requirements of the Chinese national standard GB50150-2006, including the sheath handover test and preventive test for cross-bonded systems. It quickly and accurately finds outer-sheath ground faults and excessive leakage current in 10kV–500kV single-core and three-core high-voltage and extra-high-voltage cables, and can carry out 5kV–15kV, 1-minute DC withstand tests on HDPE and PVC cable outer sheaths. It is essential dedicated equipment for the cable maintenance of 10kV–500kV single-core and three-core high-voltage and extra-high-voltage cable operation units, extra-high-voltage cable engineering companies and power transmission-and-transformation engineering companies.

Technical Parameters Bridge Part
Item Specification
No-load voltage ≥15kV
Short-circuit current ≥150mA (when balancing, 5–40mA is recommended)
Positioning ratio accuracy ±(0.2%·L±1) m
Working power Supply: AC 220V (±10%), 50Hz±1Hz; balancing power: 8.4V built-in battery
Withstand-Test Part
Item Specification
Input voltage 220V (±10%), 50Hz (±2Hz)
Output voltage 0–15kVDC, adjustable
Output current 0–150mA
Output capacity 2kVA
FAQ
Q1. What cable problems can this portable sheath fault tester solve?

It locates the breakdown points of wires and cables and defect points that have not yet broken down but show a low insulation resistance, finds outer-sheath ground faults and excessive leakage current in 10kV–500kV single-core and three-core high-voltage cables, and performs 5kV–15kV, 1-minute DC withstand tests on HDPE and PVC outer sheaths.

Q2. What are the main technical parameters?

Bridge part: no-load voltage ≥15kV; short-circuit current ≥150mA (5–40mA recommended when balancing); positioning ratio accuracy ±(0.2%·L±1) m; weight 35kg; supply AC 220V (±10%), 50Hz±1Hz and an 8.4V built-in balancing battery. Withstand-test part: input 220V (±10%), 50Hz (±2Hz); output 0–15kVDC adjustable; output current 0–150mA; output capacity 2kVA.

Q3. Does the output voltage meet the relevant standard?

Yes. The output is 15kV and below, fully meeting the Chinese national standard GB50150-2006 for cable outer-sheath withstand tests, including the sheath handover test and preventive test for cross-bonded systems.

Q4. Why is the bridge-balance method used?

Compared with the wave-reflection method, the bridge-balance method has no blind zone, so it is suitable for judging short cables and breakdown points near the terminals, as well as high-resistance breakdown points that are hard to burn into low resistance and flashover-type breakdown points.

Q5. How is the equipment operated, and what protection does it provide?

Operation is by one key: enter the cable length and the fault distance is calculated automatically. On the bridge there is zero-position protection; the withstand-test part provides automatic over-current, over-voltage and over-heat protection, zero-position start protection, a unique self-discharge design (the high voltage drops to zero as soon as the output is cut off), dual current/voltage pointer meters and an over-current protection switch.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

                        Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...                         Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
  • Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
  • https://www.xzhtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement