Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"Cable Route Tracer XHLJ504L 100W Audio Frequency for Underground Cable Path","imgUrl":"https:\/\/img.chinax.com\/nimg\/96\/8e\/ddacd42d138b60dff2d53d548750-200x200-1\/cable_route_tracer_xhlj504l_100w_audio_frequency_for_underground_cable_path_detection_and_burial_depth_measurement.jpg","attrs":{"Brand Name":"XZH TEST","Model Number":"XHLJ504L","Certification":"CE\/ISO","Place of Origin":"China"}}
{"title":"Cable Identifier | High Voltage Cable Identifier AC 220V Adjustable Frequency","imgUrl":"https:\/\/img.chinax.com\/nimg\/95\/8b\/a48e28fed51bf6bfeaa0381c5c19-200x200-1\/cable_identifier_7c_high_voltage_cable_identifier_ac_220v_adjustable_frequency_power_cable_identification_instrument_7c_xhsb505.jpg","attrs":{"Price":"Negotiable","Brand Name":"XZH TEST","Model Number":"XHSB505","Certification":"ISO CE"}}
{"title":"Cable Identifier | High Power AC Cable Identification Instrument with Adjustable","imgUrl":"https:\/\/img.chinax.com\/nimg\/42\/4f\/6118129b04469203e7a2cb721013-200x200-1\/cable_identifier_7c_high_power_ac_cable_identification_instrument_with_adjustable_signal_frequency_7c_xhsb505.jpg","attrs":{"Price":"Negotiable","Brand Name":"XZH TEST ISO\/CE","Model Number":"XHSB505","Place of Origin":"Xi'an, Shaanxi, China"}}
{"title":"Cable Identifier | Multifunctional Live De-energized Cable Identifier Power","imgUrl":"https:\/\/img.chinax.com\/nimg\/c4\/54\/d63b49331e27ec0092afedd79934-200x200-1\/cable_identifier_7c_multifunctional_live_de_energized_cable_identifier_power_cable_identification_tester_for_engineers_7c_xhsb505d.jpg","attrs":{"Brand Name":"XZH TEST","Model Number":"XHSB505DS","Certification":"ISO CE","Place of Origin":"Xi'an ShanXi China"}}
The XHSB505B Cable Identifier is designed for high-voltage cable construction, installation and maintenance personnel who need a practical way to identify a specific cable among many cables on site. Guided by electromagnetic field theory and built with modern electronic technology and tooling, it delivers fast and accurate cable identification. In power cable laying, relocation, maintenance and fault handling, one of the most troublesome problems is determining which cable is the one you are looking for — especially in cable trenches where many cables of the same specification run together. This device solves that problem quickly and accurately.
Key Features
Accurate, error-free identification
Large identification clamp suitable for a wide range of cables
Extremely simple operation
Clear and intuitive indication
Portable and neat main and auxiliary parts
Adjustable receiver signal strength
Identifies both de-energized (dead) and live cables
Compact, portable and lightweight
How It WorksDe-energized (dead) cable identification
The transmitter generates a special pulse signal that is applied to the cable to be identified through the connecting line. Based on the principle of electromagnetic induction, a signal consistent with the transmitted signal is induced along the cable. On site, a high-sensitivity receiver clamp combined with the handheld receiver is used to test all cables present, and the target cable (the de-energized cable carrying the injected signal) can be identified accurately from the indication on the handheld receiver.
Live (energized) cable identification
The transmitter generates a special pulse signal that is applied to one point of the live cable to be identified through the dedicated transmitter clamp. Based on the principle of electromagnetic induction, a signal consistent with the transmitted signal is induced along the cable. On site, a high-sensitivity receiver clamp combined with the handheld receiver is used to test all cables present, and the target cable (the live cable carrying the injected signal) can be identified accurately from the indication on the handheld receiver.
Technical Parameters
Item
Specification
Identification Method
Determined by the swing direction of the meter pointer
Transmitter Clamp
Φ125 mm
Receiver Clamp
Φ200 mm
Output Voltage
Position I (direct connection method): 150 V; Position II (coupling method): 250 V
Operating GuideDe-energized (dead) cable identification — direct connection method
Transmitter wiring
Method 1: connect the red test line of the transmitter to the cable core (any one phase is sufficient); connect the black test line to ground; and connect the far end of the phase connected to the red test line to earth (the cable shield and armor are not grounded).
Method 2: (1) connect the red test line to the cable core (any one phase is sufficient); (2) connect the black test line to the copper shield or cable armor; (3) connect the far end of the phase connected to the red test line to the copper shield or cable armor; (4) check the grounding state of the copper shield or cable armor.
Method 3: when the resistance of the grounding loop is too large or unreliable, the states differ. In these states the transmitted signal may fail to load or may be cancelled, and the identification effect is not ideal. If this occurs, check and adjust the wiring and use the wiring of Method 1 or Method 2.
Cable identification is affected by the grounding condition of the grounding system and by whether the cable shield or armor is intact; the two wiring methods above give the most ideal identification results.
Operating steps
Turn on the transmitter power switch and set the position switch to "I". The power light blinks three times and the ammeter pointer also swings three times at the same frequency, cyclically outputting the pulse signal.
Connect the receiver to the receiver clamp, and clamp the receiver clamp onto the cable to be tested.
Note the arrow direction of the receiver clamp (the arrow points to the far end), otherwise the pointer will swing in the opposite direction.
Turn the receiver adjustment knob clockwise; when you hear a "beep" and the indicator lights up, the receiver switch is on. Then adjust the received signal strength to a suitable position. At this time, only the cable carrying the injected signal receives continuous characteristic signals in the same direction (three times), with a swing frequency consistent with the transmitter, and emits a "beep-beep-beep" sound.
Live (energized) cable identification — coupling method
Precautions
No operation on the tested cable is needed; directly clamp the transmitter clamp onto the cable for testing.
Both ends of the cable sheath must be well grounded, otherwise the coupling current decreases as the grounding resistance increases.
If the sheath is not grounded at both ends or is broken in the middle, the coupling method cannot be used.
When clamping the transmitter clamp onto the cable, the arrow on the clamp points toward the far end of the cable.
Keep the receiver clamp at least 2 m away from the transmitter clamp.
Operating steps
Connect the transmitter output to the transmitter clamp, and clamp the transmitter clamp at a suitable position on the live cable to be identified, with the clamp arrow pointing to the cable far end.
Turn on the transmitter power switch and select position "II"; the power light blinks three times and the ammeter pointer also swings three times at the same frequency, cyclically outputting the pulse signal.
Connect the receiver clamp to the receiver, and clamp the receiver clamp onto the cable to be tested.
Note the arrow direction of the receiver clamp, which points to the cable far end, otherwise the pointer swings in the opposite direction.
Turn the receiver adjustment knob clockwise; when you hear a "beep" and the indicator lights up, the receiver switch is on. Then adjust the received signal strength to a suitable position. At this time, only the cable carrying the injected signal receives the signal, with a swing frequency consistent with the transmitter output switching frequency, and emits a "beep-beep-beep" sound.
If the required cable cannot be identified with the coupling method, the direct connection method is recommended.
Safety Precautions & Warnings
Read this manual in detail and follow the relevant precautions.
The instrument can be used both indoors and outdoors, but it should be kept away from rain, corrosive gas, heavy dust and high temperature.
The operator should have general knowledge of using electrical equipment or instruments.
This is a high-precision instrument and should be protected from severe vibration.
Repair, care and adjustment of the instrument should be carried out by professionals.
Charge the transmitter once every 2 months for maintenance, to avoid battery damage.
During testing, adjust the received signal strength of the receiver to a suitable level (neither too high nor too low), and do not adjust it during the test.
After the cable to be tested has been identified, the cable must be punctured (spiked) before construction to ensure safety.
When the receiver clamp is clamped on the cable to be tested, make sure the clamp jaws make good contact. Dust, gaps or loose contact on the jaws will all affect signal reception.
If the pointer on the receiver does not swing obviously on site, check whether the receiver clamp is in good contact.
When identifying a live cable, if severe interference causes the receiver clamp to magnetically saturate and no signal can be received, it is recommended to use the de-energized method for identification.
The instrument can be directly short-circuited for testing.
When the receiver pointer swing frequency is inconsistent with the transmitter, or the swing amplitude is too small, the received signal is too weak: turn the receiver adjustment knob clockwise to increase the received signal strength.
When the receiver pointer swings irregularly or does not swing at all, the interference signal is too strong, or the tested cable is not the target cable.
After-Sales Service
The instrument comes with a one-year free warranty for quality problems from the date of purchase, and lifetime repair and technical service are provided. If you find that the instrument is not operating normally or a fault occurs, please contact us so that we can arrange the most convenient and effective solution for you. Service phone: 400-029-0829.
FAQ
Q1. Can the XHSB505B identify both live and de-energized cables? Yes. The direct connection method (position "I") is used for de-energized cables, and the coupling method (position "II") is used for live cables. Both methods use the same principle of injecting a pulse signal and reading the indication on the handheld receiver.
Q2. How do I know which of the cables is the target one? Identification is based on the swing direction of the meter pointer. Only the cable carrying the injected signal shows continuous characteristic signals in the same direction, with a swing frequency consistent with the transmitter, and emits a "beep-beep-beep" sound. Note the arrow direction of the receiver clamp — the arrow points to the far end — otherwise the pointer swings in the opposite direction.
Q3. What should I do if the pointer swings too weakly or irregularly? If the pointer swing frequency is inconsistent with the transmitter or the swing amplitude is too small, the received signal is too weak: turn the receiver adjustment knob clockwise to increase the received signal strength. If the pointer swings irregularly or not at all, the interference is too strong or the tested cable is not the target cable. When identifying a live cable with severe interference that causes the receiver clamp to magnetically saturate, it is recommended to use the de-energized method.
Q4. Do I need to power off the cable before testing? Not necessarily. For live cables, use the coupling method: clamp the transmitter clamp directly onto the cable with no operation on the tested cable. Both ends of the cable sheath must be well grounded; if the sheath is not grounded at both ends or is broken in the middle, the coupling method cannot be used and the direct connection method is recommended instead. Also keep the receiver clamp at least 2 m away from the transmitter clamp.
Q5. What is included in the package, and what about after-sales service? The standard package includes the transmitter, receiver, charger, one red output line, one black output line, one transmitter clamp, one receiver clamp and two AA (No. 5) batteries. The instrument comes with a one-year free warranty for quality problems from the date of purchase, plus lifetime repair and technical service.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd.
Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd.
Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...