ARC Multi-Pulse Cable Fault Pre-Locator 10.1-inch Touch 120km Range 400MHz
TDR Cable Fault Pre-Locator Portable with Printer 30km Range 5.7-inch LCD
ARC Multi-Pulse Cable Fault Pre-Locator 400MHz 120km Range 0.07m Resolution with
ARC Cable Fault Pre-Locator with Report Generator | 12.1-inch 400MHz 68km |
Product Specification
| Payment Terms | T/T | Supply Ability | 3000unit/year |
| Delivery Time | 5-8 work days | Packaging Details | wooden packaging |
| Brand Name | XZH TEST | Model Number | XHGG502A |
| Certification | ISO CE | Place of Origin | Xi'an ShanXi China |
| High Light | Smart Cable Fault Locator ,TDR Cable Tester ,Low Voltage Cable Fault Detector | ||
XHGG502A电缆故障预定位仪是一款用于测量和分析电力电缆状况及故障距离的专用仪器.它采用工业级10.1英寸触摸屏一体机,配备简易的操作软件界面,方便人机交互测试;并采用工业级集成电路和元器件,内置高容量锂离子电池,确保了仪器的稳定性,可靠性和易用性.
它结合了现代电子和计算机技术,实现了信号滤波,采集,数据处理,图形显示和图形分析,从而完成了电缆速度测量,电缆长度测试和电缆故障距离测试.它适用于各种截面和介质的电力电缆,高频同轴电缆,路灯电缆和埋地电缆的低阻,短路,开路和断路故障,以及高阻泄漏和高阻闪络故障.
主要特点当电磁波在不均匀的传输线中传播时——即某点的特性阻抗发生变化时——波不仅会继续向前传播,还会产生反向传播回到测试端.这种反向传播的波称为反射波,这种现象称为反射;入射波和反射波合起来称为行波.在短路点,回波的极性与发射脉冲的极性相反;而在开路点(包括电缆端子),回波的极性与发射脉冲的极性相同.因此,低阻故障和开路故障可以根据回波极性,通过低压脉冲法轻松定位.对于高阻故障,则采用高压闪络法:高压脉冲信号源(漏电高阻故障)或直流高压电源(闪络高阻故障)在故障点产生闪络放电,产生反射信号,该信号在测试端被检测到.反射信号随后通过高速 A/D 转换器和计算机控制系统,从模拟信号转换为数字信号,存储并进行数字处理,然后发送到显示器进行波形分析——完成故障距离的粗略测量.
低压脉冲法对被测电缆施加低压脉冲信号;脉冲在故障点反射,测试仪处理反射信号并显示波形,通过分析反射波形确定粗略故障距离.
高压闪络法The system includes an integrated high-voltage generator capable of generating a single-impact high voltage, a multiple-pulse generator, a multiple-pulse automatic triggering device and test waveform analysis software. The multiple-pulse generator guides the instantaneous high-voltage pulse onto the faulty phase, ensuring sufficient breakdown at the fault point and extending the arc duration after breakdown. The automatic triggering device then immediately sends out multiple low-voltage test pulses. The first eight test pulses use the short-circuit characteristics at the moment of cable arc breakdown to form eight fault reflection pulses; after the arc extinguishes, eight more test pulses measure the cable's open-circuit reflection waveform, forming eight sets of secondary pulse waveforms. The multiple-pulse method effectively avoids the interference of the large cosine oscillations that occur under high-voltage impact, allowing clear standard echoes resembling a short-circuit fault to be obtained during the relatively stable arc — greatly simplifying the testing procedure.
Technical Specifications| Item | Specification |
|---|---|
| Sampling frequency | 1 MHz ~ 400 MHz |
| Low-voltage pulse amplitude | 300 V ±15% |
| Distance measurement range | ≥ 120 km |
| Test range | 100 m / 300 m / 500 m / 1 km / 3 km / 5 km / 10 km / 25 km / 50 km / 100 km |
| Pulse width | 0.1 µs / 0.30 µs / 0.60 µs / 1.20 µs / 2.4 µs / 5.0 µs / 7.5 µs / 10 µs |
| Minimum resolution | 0.07 m |
| Test blind zone | ≤ 10 m |
| Measurement error | ≤ ±(0.5% × L + 1 m), where L is the cable length |
| Power supply | Rechargeable AC 110 V ~ 240 V, 50 Hz / 60 Hz; built-in 11.1 V lithium battery pack; charging time approximately 2 hours, working time over 5 hours |
| Pulse coupler withstand voltage | DC 35 kV |
| Operating conditions | Temperature -20 ℃ ~ +65 ℃; relative humidity 90%; atmospheric pressure 750 ±30 mmHg |
After the boot screen the system operation interface is shown. The main interface is divided into a working-status indicator area, a waveform display area, an instrument parameter display area, a function setting area and an instrument operation area. The working-status area displays "Standby Status" when the instrument is ready and switches to "Sampling Status" when the sampling button is pressed.
The function setting area includes: medium speed (cross-linked, oil-immersed and rubber cable types; cable propagation speed can be customised); operating modes (five methods: pulse, flashover, velocimetry, multiple measurements and megohmmeter); test range (100 m / 300 m / 500 m / 1 km / 3 km / 5 km / 10 km / 25 km / 50 km / 100 km); file processing (save the current waveform, open previously saved waveforms for comparison, and export waveform files to PC software); sample / hold (start and stop sampling; the waveform display area then refreshes in real time); and system settings (set the system time, turn the auto-range function on / off, adjust brightness and turn the operation feedback buzzer on / off).
The waveform display area shows the real-time sampled waveform in the middle, the test results and distance / wave velocity on the right, and the current instrument parameters at the bottom. The instrument operation area provides amplitude adjustment (three levels X1, X2 and X3; can also be adjusted with the panel amplitude knob during sampling), baseline adjustment (in sampling mode, adjust the upper and lower baseline positions with the "baseline up" and "baseline down" buttons), waveform compression (in hold, use the "Waveform Compression" button to compress or expand the waveform), cursor (while holding the distance, press the "Cursor" button and select cursor 1 or cursor 2, then use the left / right keys to adjust the cursor positions, or press and drag the bottom of the cursor; there are 6 levels X1–X6, where a larger number means a greater distance per step) and automatic measurement (in hold or sampling mode, pressing "Automatic Measurement" automatically calculates the distance result).
Low-voltage pulse methodThe instrument is covered by a one-year warranty from the date of purchase for product quality issues, and lifetime maintenance and technical services are provided. If you find any abnormality or malfunction in the instrument, please contact us so that we can arrange the most convenient and effective solution for you.
FAQQ1. What cable faults can the XHGG502A test?
It tests low-resistance, short-circuit, open-circuit and broken-circuit faults, as well as high-resistance leakage and high-resistance flashover faults. It is applicable to power cables, high-frequency coaxial cables, streetlight cables and buried wires of various cross-sections and media. Low-resistance and open-circuit faults are judged with the low-voltage pulse method, while high-resistance faults are tested with the high-voltage flashover method.
Q2. What are the test methods, range and accuracy?
The instrument supports the low-voltage pulse method, the high-voltage flashover method (direct flashover and impulse flashover), the multiple-pulse method (8 pulses) and velocimetry. Sampling frequency is 1 MHz–400 MHz, the low-voltage pulse amplitude is 300 V ±15%, the distance measurement range is ≥ 120 km, the test range is 100 m to 100 km, the minimum resolution is 0.07 m, the test blind zone is ≤ 10 m and the measurement error is ≤ ±(0.5% × L + 1 m).
Q3. How is it powered, and how should the battery be cared for?
It charges from AC 110 V–240 V, 50 Hz / 60 Hz and works from a built-in 11.1 V lithium battery pack; charging takes approximately 2 hours and working time is over 5 hours. High-voltage flashover and multiple-pulse sampling are strictly prohibited while charging, and if the instrument is not used for a long time it should be charged about every 2 months.
Q4. Is the coupler included for the multiple-pulse method?
Yes. This configuration is supplied with the coupler, so the multiple-pulse method can be used directly. Used with the pulse coupler, the multiple-pulse method displays 8 sets of high / low voltage waveforms for comparison, making automatic distance testing, manual analysis and distance measurement easier. Note that the coupler connection lines must only be plugged / unplugged, never rotated or twisted.
Q5. What is included in the package, and what about after-sales service?
The packing list includes the cable fault tester (1 unit), power cord (1 pc), single Q line (1 pc), double Q line (1 pc), sampling box (1 pc), coupler host (1 unit), transparent grounding wire (1 pc), coupler high-voltage line A (1 pc), coupler high-voltage line B (1 pc) and USB communication cable (1 pc). The instrument is covered by a one-year warranty for product quality issues from the date of purchase, plus lifetime maintenance and technical services
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical... Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...
Get in touch with us
Leave a Message, we will call you back quickly!