Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"11kv 33kv Electric Power Cable Fault Locator 8\/16\/32kv 1000j Hv Pulse Generator","imgUrl":"https:\/\/img.chinax.com\/nimg\/82\/82\/b9817ca9489c486ca27eab6737fe-200x200-1\/11kv_33kv_electric_power_cable_fault_locator_8_2f16_2f32kv_1000j_hv_pulse_generator.jpg","attrs":{"Brand Name":"XZH Test","Model Number":"XHHV535-2T","Certification":"CE\/ISO","Place of Origin":"China"}}
{"title":"Low Voltage Hidden Cable Fault Locator For Detecting Earth Leakage Broken Core","imgUrl":"https:\/\/img.chinax.com\/nimg\/3b\/ff\/55d9145aca0f6f9a5e77f2531979-200x200-1\/low_voltage_hidden_cable_fault_locator_for_detecting_earth_leakage_broken_core_cable.jpg","attrs":{"Brand Name":"XZH TEST","Model Number":"XHHD530M","Certification":"CE","Place of Origin":"Xi'an, Shaanxi, China"}}
{"title":"Portable Underground Cable Fault Locator Set High Voltage 8 \/ 16 \/ 32kV 2000j","imgUrl":"https:\/\/img.chinax.com\/nimg\/ad\/ee\/7b07dded8db31bccf67e7d07d997-200x200-1\/portable_underground_cable_fault_locator_set_high_voltage_8_2f_16_2f_32kv_2000j.jpg","attrs":{"Certification":"CE, ISO","Payment Terms":"T\/T","Brand Name":"XZH Test","Model Number":"502+503C+507+535-4TS"}}
{"title":"Cable Thumper High Voltage Pulse Generator For Cable Fault Location","imgUrl":"https:\/\/img.chinax.com\/nimg\/5b\/76\/26a5e4c5b015e4c14e1560adb532-200x200-1\/cable_thumper_high_voltage_pulse_generator_for_cable_fault_location.jpg","attrs":{"Brand Name":"XZH TEST","Model Number":"XHHV535-4T","Certification":"CE","Place of Origin":"Xi'an, Shaanxi, China"}}
{"title":"High Voltage Surge Generator Cable Fault Locating Equipment Trolley Three","imgUrl":"https:\/\/img.chinax.com\/nimg\/3d\/80\/291b3d75db3592ceb9857a1af3a3-200x200-1\/high_voltage_surge_generator_cable_fault_locating_equipment_trolley_three_voltage_shielded.jpg","attrs":{"Certification":"CE, ISO","Brand Name":"XZH Test","Model Number":"XHHV535-4TS","Place of Origin":"China"}}
{"title":"HV Surge Generator 1000j 0-32kv for Portable DC Withstand Pulse Discharge","imgUrl":"https:\/\/img.chinax.com\/nimg\/20\/5d\/bad8c4670258300d2950410fc36c-200x200-1\/hv_surge_generator_1000j_0_32kv_for_portable_dc_withstand_pulse_discharge.jpg","attrs":{"Certification":"CE, ISO","Brand Name":"XZH Test","Model Number":"XHHV535-2L","Place of Origin":"China"}}
{"title":"With Path Deviation Indication Function Audio Cable Tester","imgUrl":"https:\/\/img.chinax.com\/nimg\/91\/de\/32c70492255db117f12194084bf2-200x200-1\/with_path_deviation_indication_function_audio_cable_tester.jpg","attrs":{"Certification":"CE, ISO","Brand Name":"XZH TEST","Model Number":"XHDD503E","Place of Origin":"Xi'an, Shaanxi, China"}}
Description The XHHV535-4T high voltage surge generator is currently the most user-friendly trolley-type DC impulse high-voltage equipment.It can be used for shock discharge in the detection of medium and low voltage cable faults.High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.
Panel introduction 1. Ammeter: Indication of the current size on the low-voltage side. 2. Voltmeter: Indication of high-voltage output voltage kV meter. 3. High-voltage lamp (HV): On indicates high-voltage output, off indicates no high-voltage output. 4. Power lamp (Power): After turning on the power switch, the indicator light is on. 5. Zero position lamp (Zero): Indicates that the voltage adjustment knob is in the zero position state. The high voltage can only be started when the zero position lamp is on. 6. Overcurrent protection switch: Pressing the state indicates that the overcurrent protection function has started; when it pops up, it indicates that the instrument has triggered the overcurrent protection. 7. Power switch (Power Switch): Turn clockwise to turn on the system power supply, and counterclockwise to turn off the cable fault test device 112 system power supply. 8. Single key (Single): When the mode selection key is in the Single function, this key is valid. 9. Mode selection (Mode select): It is divided into three modes: withstand voltage (DC), single (Single), and cycle (Cycle). DC is the withstand voltage function. When this function is selected, the cable will be subjected to withstand voltage test; Single is a manual function. When this function is selected, the high voltage will be started and then boosted. Pressing the Single key can manually trigger the impact discharge; Cycle is an automatic function. When this function is selected, the high voltage will be started and boosted. The instrument will automatically trigger the impact discharge for about 7 seconds. 10. Start button (Start): In the zero position state, press the start button, the high voltage will start, and the high voltage light will be on. In the non-zero position state, the high voltage light will not be on when started. 11. Stop button (Stop): When the test is completed or an abnormality occurs, press this button to cut off the high voltage output. At this time, the remaining high voltage of the test will also be automatically discharged. 12. Voltage control knob (Voltage control): When this knob is in the zero position state, the zero position light will be on, and the high voltage can be started. The voltage can only be boosted through the voltage control knob after the high voltage is started.
Technical parameters
Impact high voltage
0~35kV
High voltage partial pressure
2.5 level
Built-in capacitor
2μF
Discharge power
1225J
Impact power
2000W
Output voltage polarity
negative polarity
Impact time
about 7 seconds for automatic impact, arbitrary control time for manual impact
Over current protection
10A (more than 5 seconds) Low voltage side
Volume(mm)
534L×444W×805H
Weight
not more than 120kg
Power supply
AC220V±10%, 50Hz±2Hz(60Hz)
Ambient temperature
-20~+60ºC
Packing List
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. has found in 2013, located in Xi'an, China. which is a highly experienced team dedic...
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. has found in 2013, located in Xi'an, China. which is a highly experienced team dedic...