| Payment Terms | T/T |
| Supply Ability | 3000unit/year |
| Delivery Time | 5-8 work days |
| Packaging Details | wooden packaging |
| Brand Name | XZH TEST |
| Model Number | XHJL309 |
| Certification | ISO CE |
| Place of Origin | Xi'an Shaanxi China |
View Detail Information
Explore similar products
Wireless Zinc Oxide Surge Arrester Live Tester 0-10mA 25V-250V Six Test Modes 8
Wireless Zinc Oxide Arrester On-Line Tester LCD Fundamental Wave 3rd to 7th
Handheld Zinc Oxide Surge Arrester Live Tester Wireless Six Test Methods
Wireless Zinc Oxide Arrester Live Tester 433MHz 100m 0-10mA Resistive Current
Product Specification
| Payment Terms | T/T | Supply Ability | 3000unit/year |
| Delivery Time | 5-8 work days | Packaging Details | wooden packaging |
| Brand Name | XZH TEST | Model Number | XHJL309 |
| Certification | ISO CE | Place of Origin | Xi'an Shaanxi China |
| High Light | Sulfur Hexafluoride Analysis ,Two-thirds Gas Saving ,Dew Point Curve Display | ||
Integrating a micro-moisture meter, a purity tester and a decomposition product analyzer into a single unit, this device combines the functions that previously required three separate instruments. A single on-site measurement enables the testing of three indicators, which significantly reduces gas consumption for the equipment, cutting gas usage by two-thirds per measurement and boosting work efficiency substantially.
Sulfur hexafluoride (SF6) is the preferred insulating and arc-extinguishing medium for high-voltage switchgear, circuit breakers, gas-insulated switchgear and gas-insulated lines. The quality of the gas determines the reliability of the equipment: excessive moisture causes condensation and flashover, low purity weakens insulation, and decomposition products reveal internal discharge and arcing activity. This tester delivers all three answers in one connection.
With the dew point measured in 5 minutes and the purity and decomposition products measured in 2 minutes, the instrument keeps testing time to a minimum. The original German imported self-locking connectors guarantee a leak-free gas path, and the built-in 4Ah rechargeable lithium battery provides 10 hours of continuous operation for full-day inspection programs in industrial plants and factories.
| Parameter | Specification |
|---|---|
| Purity Measurement | 0% ~ 100%, accuracy ±0.5% |
| Dew Point Range | -80 °C ~ +20 °C, accuracy ±0.5 °C (-80 °C ~ -60 °C) |
| Dew Point Response | 63% in 10 seconds, 90% in 240 seconds / 63% in 5 seconds, 90% in 45 seconds |
| H2S Measurement | 0 ~ 200 ppm, accuracy ±0.5%, resolution 0.1 ppm |
| SO2 Measurement | 0 ~ 200 ppm, accuracy ±0.5%, resolution 0.1 ppm |
| CO Measurement | 0 ~ 1000 ppm, accuracy ±0.5%, resolution 1 ppm |
| Test Speed | Dew point in 5 minutes; purity and decomposition products in 2 minutes |
| Data Storage | 200 sets of test data |
| Display | Large screen with dew point measurement curve |
| Connectors | Original German imported self-locking connectors, no gas leakage |
| Built-in Power Supply | 4Ah rechargeable lithium battery, 10 hours continuous operation |
| Ambient Temperature | -40 °C ~ +60 °C |
| Ambient Humidity | 0 ~ 100% RH |
SF6 equipment passes through six stages in its service life. The tester supports the gas quality verification required at every stage, from first filling to final decommissioning.
| Lifecycle Stage | Activity | Testing Requirement |
|---|---|---|
| 1. New gas acceptance | Receiving new SF6 gas from the supplier | Verify purity and dew point before filling into the equipment |
| 2. Installation and filling | Filling the equipment with SF6 after assembly | Confirm the dew point and purity after the first filling |
| 3. Commissioning | Putting the equipment into service | Baseline measurement of dew point, purity and decomposition products |
| 4. Routine monitoring | Periodic preventive tests during operation | Compare with the baseline to detect moisture ingress and discharge activity |
| 5. Gas top-up and repair | Topping up gas or repairing after a fault | Measure decomposition products to assess internal arcing damage |
| 6. Decommissioning and recovery | Removing the equipment from service | Final gas quality record before gas recovery and recycling |
A stable dew point within the equipment specification indicates a healthy seal and drying system. A rising dew point trend between tests warns of moisture ingress through seals or gaskets, and requires investigation before the moisture level reaches the condensation risk zone.
Purity close to the rated value confirms the insulation and arc-extinguishing capability of the gas. A noticeable purity drop indicates contamination or leakage, and the gas should be topped up or treated before the equipment is returned to full service.
Low and stable H2S, SO2 and CO values mean no significant discharge activity. Rising SO2 and H2S values indicate internal arcing or partial discharge and call for internal inspection; rising CO indicates decomposition of organic materials such as seals and insulation.
Every sulfur hexafluoride tester is delivered with the main unit, self-locking connectors, gas hoses, charging adapter and operation manual, and is backed by one-year free warranty and lifetime technical service. For ordering, training and after-sales support, please contact our sales team.
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical... Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...
Get in touch with us
Leave a Message, we will call you back quickly!