China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum
China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum

  1. China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum
  2. China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum
  3. China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum
  4. China SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum

SF6 Leak Detector Qualitative 0.01-500ppm 3s Response LCD Audible Alarm Vacuum

  1. MOQ: 1set
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 3000unit/year
Delivery Time 5-8 work days
Packaging Details wooden packaging
Brand Name XZH TEST
Certification ISO CE
Place of Origin Xi'an Shaanxi China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 3000unit/year
Delivery Time 5-8 work days Packaging Details wooden packaging
Brand Name XZH TEST Certification ISO CE
Place of Origin Xi'an Shaanxi China
High Light 3s Fast SF6 Detection ,Split Probe Vacuum Pump ,LCD Audible Alarm

SF6 Leak Detector (Qualitative)

Qualitative SF6 Gas Leak Detection  |  0.01-500ppm for Circuit Breakers
Product Overview

This qualitative SF6 leak detector is designed for fast, reliable detection of sulfur hexafluoride gas leakage from circuit breakers and SF6-filled equipment. The working principle is based on the fact that when the concentration of SF6 gas in the air changes, the ionization degree of the mixed gas under the action of a high-frequency electromagnetic field varies accordingly; the SF6 concentration is reflected by detecting the ionization degree. With a separate probe and main unit, a small vacuum pump draws samples through a 4-meter pipe, while an LCD display shows the gas concentration and an audible alarm sounds automatically when the measured value reaches the set threshold.

Applications & Target Audience: Engineered for live-line working centers, customs and import-export inspection agencies, work safety supervision and occupational health organizations, hydrogen energy and fuel cell infrastructure projects and UAV and robotic inspection service providers that need to detect SF6 gas leakage from circuit breakers and gas-filled equipment for equipment integrity, personnel safety, emission compliance and inspection verification.
Key Specifications
Parameter Specification
Measurement Range 0.01ppm ∼ 500ppm
Response Time Less than 3 seconds
Indication Method LCD digital display, audible and visual alarm signals
Alarm Range 0.01ppm ∼ 500ppm (settable)
Vacuum Pump Pumping speed 0.5 liters/second, pipe length 4 meters
Operating Time Continuous operation up to 4 hours
Operating Conditions AC 220V 50Hz, 7°C ∼ 40°C, humidity ≤ 85%
Design Split type: separate probe and main unit, non-toxic probe
Certification ISO / CE
Performance Features
High-Frequency Ionization Principle: Concentration is determined by measuring the ionization degree of the air-gas mixture under a high-frequency electromagnetic field, providing stable and repeatable readings.
Split Probe with Vacuum Pump: The separate probe and main unit with a 0.5 liters/second vacuum pump and 4-meter pipe reach confined spaces and elevated breaker connections easily.
Non-Toxic Safe Probe: The probe is non-toxic and does not produce toxic gases, ensuring operator safety during prolonged leak surveys.
Automatic Audible Alarm: When the measured gas concentration is greater than or equal to the set value, the instrument automatically emits an alarm sound for hands-free operation.
Fast 3-Second Response: Rapid response time supports efficient scanning of circuit breaker bays and switchyards without missing transient leak signals.
Wide 0.01-500ppm Range: Covers both fine leak tracing and gross leak confirmation, with LCD digital display and visual alarm for clear indication.
SF6 Leak Risks and Compliance
Insulation Performance Degradation: SF6 leakage reduces gas pressure and dielectric strength inside circuit breakers and GIS chambers, increasing the risk of internal flashover and equipment failure.
Greenhouse Gas Emissions: SF6 has one of the highest global warming potentials of any industrial gas; systematic leak detection supports emission reduction targets and sustainability reporting.
Personnel and Environmental Safety: Decomposition products of SF6 under arcing can be harmful; early leak detection protects maintenance personnel and the surrounding environment.
Regulatory Compliance: Utilities and industrial users are increasingly required to document SF6 inventory and leakage under environmental and safety regulations.
Cost Control: Early detection of small leaks avoids expensive emergency gas refilling, unplanned outages and extended downtime of critical switchgear.

FAQ
Q1: What is this SF6 leak detector used for?
It is used for qualitative detection of sulfur hexafluoride gas leakage from circuit breakers, GIS chambers, flanges, valves and pipe connections, with a measurement range of 0.01ppm to 500ppm.
Q2: How does the detector measure SF6 concentration?
It measures the ionization degree of the air-gas mixture under a high-frequency electromagnetic field; changes in SF6 concentration cause corresponding changes in ionization, from which the concentration is determined.
Q3: How is the result indicated?
The concentration is shown on an LCD digital display, and the instrument automatically emits an audible alarm plus visual alarm signal when the measured concentration reaches the set value.
Q4: What is the advantage of the split type design?
The separate probe and main unit, with a small vacuum pump and 4-meter pipe, allow convenient access to confined spaces and hard-to-reach breaker connections while keeping the display and controls at hand.
Q5: What are the operating conditions?
The detector operates on AC 220V 50Hz at 7 to 40 degrees C with humidity up to 85%, and supports continuous operation for up to 4 hours.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

                        Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...                         Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
  • Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
  • https://www.xzhtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement