China factories

Chat Now Send Email
China factory - Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

  • China
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase
China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase

  1. China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase
  2. China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase
  3. China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase
  4. China CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase

CT PT Analyzer Transformer Comprehensive Characteristic Tester Ratio Error Phase

  1. MOQ: 1 unit
  2. Price: Negotiable
  3. Get Latest Price
Secondary Winding Resistance 0~600Ω
Input Power AC220V±10%, 50Hz
Test Purpose CT, PT
PT Ratio Range 1~35000
Dimensions / Weight 365×290×153mm / <10kg
CT Ratio Range 1~40000
AC Load Measurement 0~1000VA
Payment Terms T/T
Phase Accuracy ±5min, resolution 0.5min
Working Environment -10℃~50℃, ≤90%RH
Packaging Details Wooden case
Optional Booster Output 0~180A
Supply Ability 2000 PCS/Year
Output 0~180Vrms, 12Arms, 36A peak
Voltage Measurement Accuracy ±0.2%
Display 5.7-inch transflective LCD
Delivery Time 5-8 days
Model NO. XHTX206
Place of Origin Xi'an, Shaanxi, China
Model Number XHTX206
Certification CE, ISO
Brand Name XZH TEST

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Secondary Winding Resistance 0~600Ω Input Power AC220V±10%, 50Hz
Test Purpose CT, PT PT Ratio Range 1~35000
Dimensions / Weight 365×290×153mm / <10kg CT Ratio Range 1~40000
AC Load Measurement 0~1000VA Payment Terms T/T
Phase Accuracy ±5min, resolution 0.5min Working Environment -10℃~50℃, ≤90%RH
Packaging Details Wooden case Optional Booster Output 0~180A
Supply Ability 2000 PCS/Year Output 0~180Vrms, 12Arms, 36A peak
Voltage Measurement Accuracy ±0.2% Display 5.7-inch transflective LCD
Delivery Time 5-8 days Model NO. XHTX206
Place of Origin Xi'an, Shaanxi, China Model Number XHTX206
Certification CE, ISO Brand Name XZH TEST
High Light CT PT Analyzer transformer ratio testerCT PT Analyzer phase accuracy testerCT PT Analyzer comprehensive characteristic tester
CT PT Analyzer (Transformer Comprehensive Characteristic Tester)| XHTX206

The XHTX206 transformer comprehensive characteristic tester is a new-generation revolutionary CT and PT testing instrument developed on the basis of traditional transformer VA characteristic, ratio and polarity testers that rely on voltage regulators, boosters and current boosters. Adopting a high-performance DSP and FPGA with advanced manufacturing technology, the instrument ensures stable and reliable performance, complete functions, high automation and high testing efficiency. It is a professional testing instrument for instrument transformers in the electric power industry.

Applications & Target Audience: Engineered for electric power utilities, metering departments, transformer manufacturers, and relay protection testing teams that perform on-site verification of current transformers (CT) and voltage transformers (PT).
Key Features
  • Complete functions: tests excitation (VA) characteristics, ratio, polarity, secondary winding resistance, secondary load, ratio error and phase error of CTs (protection, metering, TP class), as well as excitation, ratio, polarity, secondary resistance and ratio error of PT electromagnetic units.
  • On-site CT verification without standard CT, current booster, load box, voltage regulating control box or heavy high-current cables, greatly reducing workload and improving efficiency.
  • Accurate ratio and phase measurement: maximum permissible ratio error ±0.1%, maximum permissible phase error ±5min, enabling on-site testing of 0.2S class CTs with a CT ratio measurement range of 1 to 40000.
  • With the optional dedicated current booster, outputs 180A current for convenient on-site current flow testing.
  • Advanced frequency conversion method tests CT/PT VA characteristic curves and 10% error curves; outputs only up to 180V AC and 12Arms (36A peak), yet handles CTs with knee point up to 60kV.
  • Automatically outputs knee point voltage/current, 10% (5%) error curves, accurate limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence factor (Kr), saturation and unsaturated inductance.
  • Tests comply with GB1208 (IEC60044-1), GB16847 (IEC60044-6), GB1207 and other instrument transformer standards, with automatic standard selection by transformer type and class.
  • One-key CT resistance, excitation, ratio and polarity test with the same wiring for all CT tests except load testing.
  • 5.7-inch graphic transflective LCD, clearly visible in sunlight; rotary optical mouse operation; built-in printer for automatic test report printing; stores 1000 groups of test data without loss after power-off.
Technical Specifications
Main Unit
Parameter Specification
Test Purpose CT, PT
Output 0 ~ 180Vrms, 12Arms, 36A (peak)
Voltage Measurement Accuracy ±0.2%
CT Ratio Measurement Range 1 ~ 40000
CT Ratio Accuracy 1~2000: <0.1%; 2000~5000: <0.2%; 5000~35000: <0.5%
PT Ratio Measurement Range 1 ~ 35000
PT Ratio Accuracy 1~2000: <0.1%; 2000~5000: <0.2%; 5000~35000: <0.5%
Phase Measurement Accuracy ±5min, resolution 0.5min
Secondary Winding Resistance 0 ~ 600Ω, accuracy <0.5%±2mΩ
AC Load Measurement 0 ~ 1000VA, accuracy <0.5%±0.02VA
Input Power Supply AC220V ±10%, 50Hz
Working Environment -10 °C ~ 50 °C, humidity ≤90%
Dimensions / Weight 365 × 290 × 153 mm / <10kg
Optional Current Booster
Parameter Specification
Test Purpose Current flow test
Input 0 ~ 180VAC
Current Output 0 ~ 180A, accuracy <0.2%
Working Environment -10 °C ~ 50 °C, humidity ≤90%
Dimensions / Weight 200 × 150 × 170 mm / <5kg


FAQ
Q1: Who is this CT PT analyzer designed for?
It is designed for electric power utilities, metering departments, transformer manufacturers, and relay protection testing teams that perform on-site verification of current transformers and voltage transformers.
Q2: What tests can it perform on CT and PT?
It tests excitation (VA) characteristics, ratio, polarity, secondary winding resistance, secondary load, ratio error and phase error of CTs (protection, metering, TP class), and excitation, ratio, polarity, secondary resistance and ratio error of PT electromagnetic units.
Q3: What accuracy does it offer?
It offers a maximum permissible ratio error of ±0.1%, maximum permissible phase error of ±5min, and voltage measurement accuracy of ±0.2%, enabling field testing of 0.2S class CTs with a CT ratio range of 1 to 40000.
Q4: How does it handle high knee-point CTs with low output?
Based on the frequency conversion method, it outputs only up to 180V AC and 12Arms (36A peak) yet handles CTs with knee point up to 60kV, automatically deriving knee point voltage, 10% (5%) error curve, ALF, FS and other parameters.
Q5: What makes it different from a conventional CT PT tester?
Unlike conventional testers that require standard CTs, current boosters, load boxes and regulator boxes, it completes CT resistance, excitation, ratio and polarity tests with one key and the same wiring, featuring a 5.7-inch sunlight-visible LCD, built-in printer and 1000-group data storage.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

                        Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...                         Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
  • Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
  • https://www.xzhtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement