| Packaging Details | Portable pull-rod case with shock-proof foam insert, export-grade wooden outer crate |
| Functions | Intelligent diagnosis / burn-through / bridge / cross-section pre-location |
| Delivery Time | 8-10 working days |
| Bridge Output | 0-4kV DC bipolar, max 750mA |
| Data Storage | 100 history records |
| Test Range | 1-50000m |
| Humidity | ≤90%RH |
| Protection Rating | IP54 |
| Supply Ability | 200 Units per Month |
| Model NO. | XHSC-60Q |
| Power Supply | AC 100-240V, 50/60Hz, max 2kVA |
| Location Accuracy | ±(0.1%·L+1)m |
| Dimensions | 30x46x50cm |
| Display | 320x240 dot-matrix LCD, sunlight readable |
| Working Temperature | -10°C to +55°C |
| Diagnosis Output | 0-60kV DC negative, max 30mA |
| Payment Terms | T/T |
| Weight | 22kg (excluding accessories) |
| Burn-through Output | 0-60kV DC negative, max 400mA |
| Certification | CE, ISO 9001 |
| Place of Origin | Xi'an, Shaanxi, China |
| Brand Name | XZH TEST |
| Model Number | XHSC-60Q |
View Detail Information
Explore similar products
Digital Portable cable fault location 0-60kV 600mA High Voltage Burn Through
Intelligent Burn-Through Bridge Cable Fault Locator 60kV 400mA Burn-Through
60kV Intelligent Burn-Through Bridge Cable Fault Locator 750mA Digital Bridge HV
Digital Burn Through Bridge for Cable Fault Location in High Voltage Large
Product Specification
| Packaging Details | Portable pull-rod case with shock-proof foam insert, export-grade wooden outer crate | Functions | Intelligent diagnosis / burn-through / bridge / cross-section pre-location |
| Delivery Time | 8-10 working days | Bridge Output | 0-4kV DC bipolar, max 750mA |
| Data Storage | 100 history records | Test Range | 1-50000m |
| Humidity | ≤90%RH | Protection Rating | IP54 |
| Supply Ability | 200 Units per Month | Model NO. | XHSC-60Q |
| Power Supply | AC 100-240V, 50/60Hz, max 2kVA | Location Accuracy | ±(0.1%·L+1)m |
| Dimensions | 30x46x50cm | Display | 320x240 dot-matrix LCD, sunlight readable |
| Working Temperature | -10°C to +55°C | Diagnosis Output | 0-60kV DC negative, max 30mA |
| Payment Terms | T/T | Weight | 22kg (excluding accessories) |
| Burn-through Output | 0-60kV DC negative, max 400mA | Certification | CE, ISO 9001 |
| Place of Origin | Xi'an, Shaanxi, China | Brand Name | XZH TEST |
| Model Number | XHSC-60Q | ||
| High Light | Intelligent Burn Through Bridge cable fault locator ,60kV 400mA railway cable fault locator ,Metro traction power cable tester | ||
Railway and metro traction power cables run long, large-section routes through tunnels, bridges and cross-bonded sections, often terminated at GIS switchgear. The XHSC-60Q was designed for exactly these systems: its 60kV burn-through with up to 400mA arc current converts high-resistance and flashover insulation faults into measurable low-resistance faults, and the 750mA digital bridge and cross-section modes then deliver the fault distance with ±(0.1%·L+1)m accuracy over up to 50km, without dismantling GIS terminations or opening cross-bonding links.
| Parameter | Specification |
|---|---|
| Model | XHSC-60Q |
| Functions | Intelligent diagnosis, burn-through, bridge pre-location, cross-section pre-location |
| Diagnosis Output | 0-60kV DC (negative), max 30mA |
| Burn-through Output | 0-60kV DC (negative), max 400mA arc current |
| Bridge / Cross-section Output | 0-4kV DC bipolar, max 750mA test current |
| Location Accuracy | ±(0.1%·L+1)m |
| Test Range | 1-50000m |
| Display | 320x240 dot-matrix LCD, sunlight readable |
| Data Storage | Up to 100 history records |
| Power Supply | AC 100-240V, 50/60Hz, max 2kVA |
| Working Environment | -10°C to +55°C, ≤90%RH |
| Dimensions / Weight | 30x46x50cm, 22kg (excluding accessories) |
| Protection | IP54, protective earth <10Ω, emergency stop and auto discharge |
Instead of guessing the fault nature first, the XHSC-60Q runs an automatic intelligent diagnosis at up to 60kV and tells you exactly what to do next. This is how the built-in workflow decides the fastest route to the fault distance:
| Diagnosis Result | Automatic Guidance |
|---|---|
| Low-resistance fault (impedance shown) | Go directly to bridge mode or cross-section mode for distance measurement |
| High-resistance fault (impedance shown) | Raise the test voltage and retest, or start burn-through directly |
| Flashover below 3kV, current stable above 20mA after breakdown | Go directly to bridge mode or cross-section mode |
| Flashover above 3kV, or current unstable / below 20mA | Run burn-through first, then pre-locate |
| Impedance within safe operating range | Cable passes; no fault found |
In burn-through mode the unit outputs up to 60kV with a 400mA arc current to carbonize high-resistance and flashover faults into stable low-resistance faults. With the intelligent burn-through function enabled, the test stops automatically as soon as the fault impedance drops to the level required by the ranging modes, instead of running the full preset time. The bridge accuracy can be verified on site with the supplied bridge test box (33.3% reference line) whenever a suspicious reading appears.
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical... Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...
Get in touch with us