China factories

Chat Now Send Email
China factory - Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

  • China
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for
China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for

  1. China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for
  2. China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for
  3. China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for
  4. China High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for

High Current Digital Burn Through Bridge 60kV 600mA Cable Fault Pre-Locator for

  1. MOQ: 1 Unit
  2. Price: Negotiable
  3. Get Latest Price
Delivery Time 8-10 working days
Packaging Details Portable pull-rod case with shock-proof foam insert, export-grade wooden outer crate
Test Range 1-50000m
Operating Temperature -10\u2103 to +55\u2103
Burn-Through Output Voltage 0-60kV continuously adjustable
Power Supply 220V AC\u00b110%, 50Hz
Positioning Accuracy \u00b1(0.2%\u00b7L+1)m
Payment Terms T/T
Supply Ability 200 Units per Month
Suitable Cable Types XLPE, PILC, EPR - all MV/HV insulation types
Power Consumption 2kVA, generator compatible (>2kW)
Bridge Mode Output Voltage 0-4kV continuously adjustable
Bridge Mode Short Circuit Current 600mA
Burn-Through Short Circuit Current 600mA
LCD Display 3.5 inch TFT color screen
Maximum Cable Section 2,500mm\u00b2 (tested on 220kV XLPE)
Place of Origin Xi'an, Shaanxi, China
Model Number XHSC-60Q
Brand Name XZH TEST
Certification CE, ISO

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 8-10 working days Packaging Details Portable pull-rod case with shock-proof foam insert, export-grade wooden outer crate
Test Range 1-50000m Operating Temperature -10\u2103 to +55\u2103
Burn-Through Output Voltage 0-60kV continuously adjustable Power Supply 220V AC\u00b110%, 50Hz
Positioning Accuracy \u00b1(0.2%\u00b7L+1)m Payment Terms T/T
Supply Ability 200 Units per Month Suitable Cable Types XLPE, PILC, EPR - all MV/HV insulation types
Power Consumption 2kVA, generator compatible (>2kW) Bridge Mode Output Voltage 0-4kV continuously adjustable
Bridge Mode Short Circuit Current 600mA Burn-Through Short Circuit Current 600mA
LCD Display 3.5 inch TFT color screen Maximum Cable Section 2,500mm\u00b2 (tested on 220kV XLPE)
Place of Origin Xi'an, Shaanxi, China Model Number XHSC-60Q
Brand Name XZH TEST Certification CE, ISO
High Light High Current Digital Burn-Through Bridge ,60kV Cable Fault Pre-Locator ,Large Section Cable Tester
XHSC-60Q High Current Burn Through Bridge — 60kV/600mA for Large Section Cable Fault Pre-Location

The XHSC-60Q is a high-current digital burn-through bridge engineered specifically for rapid high-resistance-to-low-resistance fault conversion on large-section, long-distance high-voltage power cables. With a burn-mode output of 60kV and a short-circuit current of 600mA — the highest in its class — it reliably breaks down carbonized discharge channels in oil-paper and XLPE insulated cables where lower-current instruments struggle to achieve stable conduction.

Performance Highlight: 600mA short-circuit current in burn-through mode — three to six times higher than conventional 100–200mA burn-through instruments. This means faster fault conditioning, fewer burn-through cycles, and more accurate subsequent bridge positioning on large-section cables with high-resistance faults.

XHSC-60Q Detail Photos
Why 600mA Matters for Large Section Cables

High-resistance cable faults — particularly in long, large-conductor cables — present a high-impedance discharge path. A burn-through instrument with only 100–200mA of short-circuit current often requires repeated cycles to carbonize and stabilize the fault channel, and in some cases fails to achieve sufficiently low resistance for accurate bridge measurement. The XHSC-60Q’s 600mA output delivers proportionally higher energy into the fault point, accelerating the transition from unstable high-resistance arc to a stable low-resistance conduction path.

Once the fault is conditioned, the integrated intelligent bridge module takes over. Operating at 0–4kV with the same 600mA current capability, it drives sufficient test current through the now-low-resistance fault to ensure clean, repeatable ratio measurements — critical for achieving the specified ±(0.2%·L+1)m positioning accuracy.

Technical Specifications
Parameter Specification
Burn-Through Output Voltage 0–60kV continuously adjustable
Burn-Through Short Circuit Current 600mA
Bridge Mode Output Voltage 0–4kV continuously adjustable
Bridge Mode Short Circuit Current 600mA
LCD Display 3.5 inch TFT color screen
Positioning Accuracy ±(0.2%·L+1)m
Test Range 1–50,000m
Suitable Cable Types XLPE, PILC, EPR — all MV/HV insulation types
Maximum Cable Section 2,500mm² (tested on 220kV XLPE)
Power Supply 220V AC±10%, 50Hz
Power Consumption 2kVA (generator compatible, >2kW)
Operating Temperature -10°C to +55°C
Fault Conditioning Workflow
Step 1 — HV Withstand Test: Apply gradually increasing DC voltage using the burn-through mode to verify insulation condition and confirm the fault is still present
Step 2 — Burn-Through: Deliver 60kV/600mA into the fault point. Monitor voltage and current meters — as the fault carbonizes, voltage drops and current stabilizes, indicating successful conversion to low resistance
Step 3 — Bridge Pre-Location: Switch the turntable selector to bridge mode. Connect the four-wire shielded measurement cable. Use the rotary encoder knob on the 3.5-inch TFT display to select bridge, cross-section, or voltage comparison method based on available cable data
Step 4 — Pinpointing: With the fault pre-located, deploy acoustic-magnetic pinpointing (separate instrument) at the indicated distance for final excavation confirmation
Target Applications
High-resistance insulation faults on 33kV–220kV XLPE transmission cables (up to 2,500mm² conductor cross-section)
Oil-paper (PILC) cable faults where moisture ingress has created unstable, high-impedance discharge paths
Cable sheath faults on long cross-interconnected HV circuits requiring simultaneous burn-through of multiple sheath discontinuities
Pre-commissioning fault location on newly installed cables where construction damage has created latent high-resistance defects
Safety and Protection

The XHSC-60Q incorporates dual overload and short-circuit protection with autoranging impedance matching. A high-voltage enable mushroom button provides emergency power-off. The high-voltage adjustment knob is interlocked with the HV switch — boost voltage is only possible when the knob is returned to zero and the mode indicator confirms bridge or burn-through selection. All operations are conducted via an insulated rotary encoder at ground potential, with the LCD display and bridge electronics floating at high potential for measurement accuracy while the operator remains entirely isolated.

About XZH TEST: With over 15 years of specialization in cable fault location technology, XZH TEST provides complete diagnostic solutions — from TDR pre-locators and surge generators to burn-through bridges and acoustic-magnetic pinpointers. All products meet IEC 61010-1 safety requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

                        Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...                         Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. Has found in 2013, located in Xi'an, China. which is a highly experienced team dedicated to developing electrical...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
  • Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China
  • https://www.xzhtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement