Payment Terms | T/T |
Brand Name | XZH TEST |
Model Number | XHDD503C |
Certification | CE ISO |
Place of Origin | China |
View Detail Information
Explore similar products
Low Voltage Hidden Cable Fault Locator For Detecting Earth Leakage Broken Core
Portable Underground Cable Fault Locator Set High Voltage 8 / 16 / 32kV 2000j
Cable Thumper High Voltage Pulse Generator For Cable Fault Location
High Voltage Surge Generator Cable Fault Locating Equipment Trolley Three
Product Specification
Payment Terms | T/T | Brand Name | XZH TEST |
Model Number | XHDD503C | Certification | CE ISO |
Place of Origin | China | ||
High Light | Acoustic Point Determination Cable Fault Locator ,Precise Fault Detection Cable Fault Locator |
This device uses the acoustic-magnetic synchronization method to accurately determine the fault location. It is a very accurate and unique location method. Its principle is based on the traditional acoustic point determination method and adds the detection and application of electromagnetic signals.
When the high-voltage generator performs impact discharge on the faulty cable , the sound generated by the discharge at the fault point is transmitted to the ground. The sound signal is picked up by a highly sensitive probe . After amplification, a "pop" sound can be heard by listening with headphones.
The built-in probe of the probe receives the magnetic field signal in real time, and uses the principle that the propagation speed of the magnetic field is much higher than the propagation speed of sound to determine the distance of the fault point by detecting the time difference between the electromagnetic signal and the sound signal. Keep moving the sensor position to find the point with the smallest acoustic-magnetic time difference, then the exact location of the fault point will be below it.
Traditional acoustic measurement legal point instruments generally only use earphones to monitor, or are supplemented by the swing of the meter pointer to identify the discharge sound at the fault point. Since the discharge sound disappears in an instant and is not much different from the ambient noise, it often brings great difficulties to operators who are not very experienced. The acoustic-magnetic synchronization method effectively avoids the above problems of the traditional acoustic measurement method.
Principle block diagram of acoustic and magnetic synchronized point instrument
1. Cable fault locator: accurately locate cable fault points within the rough measurement range.
2. Probe: including probe, probe, connecting rod , and three claws , which are connected to the input channel to receive signals.
3. Wear headphones; connect the input channel of the pointing instrument (feedback of the output signal).
4. 7-core signal cable: connecting cable between the pointing instrument and the probe (connecting the pointing instrument and the probe).
5. Charger: Connect to the charging socket of the instrument for charging.
6. Multifunctional flower wrench: used for disassembling and assembling connecting rods.
Within one year from the date of purchase, the instrument will be covered by a free warranty for product quality issues, and maintenance and technical services will be provided for life. If you find that the instrument is in abnormal condition or has a fault, please contact us so that we can arrange the most convenient and effective solution for you .
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. has found in 2013, located in Xi'an, China. which is a highly experienced team dedic... Xi'an Xu&Hui Electromechanical Technology Co., Ltd. /Xian XZH Electric Power Technology Co., Ltd. has found in 2013, located in Xi'an, China. which is a highly experienced team dedic...
Get in touch with us