China factories

China factory - SHEN ZHEN YIERYI Technology Co., Ltd

SHEN ZHEN YIERYI Technology Co., Ltd

  • China
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 1.000-1.070SG Aquarium Salinity Tester Manual Calibration With Soft Rubber
China 1.000-1.070SG Aquarium Salinity Tester Manual Calibration With Soft Rubber

  1. China 1.000-1.070SG Aquarium Salinity Tester Manual Calibration With Soft Rubber

1.000-1.070SG Aquarium Salinity Tester Manual Calibration With Soft Rubber

  1. MOQ: 25 PCS
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union,paypal
Supply Ability 25 pcs/day
Delivery Time 5-8 work days
Packaging Details Export packing
Brix scale 0 to 10%Brix
Reference Temperature 20°C
Compensation Range 10°C~30°C (50°F~86°F)
SKU RHS-10ATC
name propylene glycol refractometer
feature durable
Brand Name YIERYI
Model Number RHS-10ATC
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union,paypal Supply Ability 25 pcs/day
Delivery Time 5-8 work days Packaging Details Export packing
Brix scale 0 to 10%Brix Reference Temperature 20°C
Compensation Range 10°C~30°C (50°F~86°F) SKU RHS-10ATC
name propylene glycol refractometer feature durable
Brand Name YIERYI Model Number RHS-10ATC
Certification CE Place of Origin CHINA
High Light handheld salinity refractometerglycol tester refractometer

Yieryi 1.000-1.070SG Salinity Seawater salinometer brix refractometer 0-10% Salinity meter

 

Specifications:
  • Manual calibration with mini-screw driver provided
  • One SCALE: Brix scale: 0 to 10%Brix;
  • Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)

Feature:

  • With Built-in ATC compensation Range (Automatic Temperature Compensation) from 10°C to 30°C
  • For field use, without having to re-calibrate after changes in ambient working temperature.
  • Soft rubber eye piece for comfortable viewing
  • Equipped with scale measurement which provides direct reading
  • Accurate testing results guaranteed
  • Extremely easy-to-use and calibrate
  • Durable and built to last long
  • Adjustable manual focusing
  • Uses ambient light only which means battery or power source is not required.
  • Cushioned with soft & comfortable non-slip rubber

 

Characteristic:

 

With Built-in ATC Compensation range (Automatic Temperature Compensation) from 10 ° C to 30 ° C


For use in the field, without the need for recalibration after changes in ambient operating temperature.


Soft rubber eye piece for comfortable viewing


A measurement scale is provided that provides direct reading


Accurate testing results are guaranteed


Extremely easy to use and calibrate


Durable and built to last a long time


Adjustable manual focus


Uses diffused light that just means a battery or power source is not required.


Soft with soft and comfortable non-slip rubber

 

 

 

Usage


Refractometer is a precision optical instrument, featuring in simple use, accurate measurement, light

 

weight, small volume and etc. By using this instrument, it can measure percent concentration of sugar

 

degree in liquid accurately. It is used for foodstuff and agricultural scientific reasearch.

 

 

 

Using method

1. Let the deviation prism point to the light, adjust the visual ring till the gage mark becomes clear.


2. Adjustment benchmark: Before using, pls keep the standard liquor (purified water), instrument and

 

liquid under measurement at the same temperature.Open the cover plate and apply 1~2 drops of

 

standard liquor onto the diviation prism, and then use hand to press the cover plate lightly to get a

 

dividing line. Turn the calibration screw to coincide the dividing line with the benchmark (0%). The one for

 

honey will be an exception.


Note: The instrument has been calibrated before delivering, you are allowed to use it directly.


3. Open the cover plate and use the soft rag to clear the surface of prism: apply 1~2 drops of liquid under

 

measurement onto the deviation prism and close the cover plate to press lightly; afterwards read the

 

relevant scale for dividing line; the reading will be the concentration value and destiny value of the liquid

 

under measurement.


4. After measuring, use the wet rag to clean the prism and cover plate; when it becomes dry, please store

 

the prism safely.

 

 
 
 

Packing list:

  • refractometer *1

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2012

  • Total Annual:

    1 Million-2.5Million

  • Ecer Certification:

    Verified Supplier

Shenzhen Yieryi Technology Co., Ltd Company Profile Company Overview Shenzhen Yieryi Technology Co., Ltd was established in 2012 and is located in the Economic Development Zone of Shenzhen City, Guangdong Province. Leveraging our superior geographic location, convenient transportation facilities, ou... Shenzhen Yieryi Technology Co., Ltd Company Profile Company Overview Shenzhen Yieryi Technology Co., Ltd was established in 2012 and is located in the Economic Development Zone of Shenzhen City, Guangdong Province. Leveraging our superior geographic location, convenient transportation facilities, ou...

+ Read More

Get in touch with us

  • Reach Us
  • SHEN ZHEN YIERYI Technology Co., Ltd
  • Room 302 Ping Ji Road 303 ping hu street Long Gang Districe Shzen Zhen City Guang Dong province China
  • https://www.yieryitools.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement