China factories

Chat Now Send Email
China factory - Hunan Yintu New Materials Co., Ltd.

Hunan Yintu New Materials Co., Ltd.

  • China,Changsha ,Hunan
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar
China Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar

  1. China Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar
  2. China Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar
  3. China Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar

Utility Scale ESS 5015 kWh Liquid Cooled DC Battery Container for Large Solar

  1. MOQ:
  2. Price: Quotation on request
  3. Get Latest Price
Cooling method Liquid cooling
Approximate weight 41 t
Corrosion protection C4; C5 optional
Installation Outdoor; non-walk-in external maintenance
Supply scope DC-side battery container
Communication interfaces CAN / Ethernet / RS485
Delivery Time Confirmed after configuration approval
Battery voltage range 1164.8–1497.6 V
BMS architecture 3-level
Auxiliary supply Approx. 40 kW; 400 V / 50 Hz; 3N + PE
System operating temperature −20 to +50°C; derating above 45°C
Cell specification LFP / 3.2 V / 314 Ah
Charge / discharge rate ≤0.5 CP
Ingress protection IP55
Temperature difference <2.5°C (battery cells)
Dimensions W × D × H 6058 × 2438 × 2896 mm
Container format 20 ft
Rated battery energy 5015.96 kWh
External protocol Modbus TCP
Nominal DC voltage 1331.2 V
Altitude ≤3000 m
Packaging Details Container transport, lifting plan and shipping arrangements confirmed for the project.
Brand Name YINTU
Model Number YT-Utility ESS-5015kWh

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Cooling method Liquid cooling Approximate weight 41 t
Corrosion protection C4; C5 optional Installation Outdoor; non-walk-in external maintenance
Supply scope DC-side battery container Communication interfaces CAN / Ethernet / RS485
Delivery Time Confirmed after configuration approval Battery voltage range 1164.8–1497.6 V
BMS architecture 3-level Auxiliary supply Approx. 40 kW; 400 V / 50 Hz; 3N + PE
System operating temperature −20 to +50°C; derating above 45°C Cell specification LFP / 3.2 V / 314 Ah
Charge / discharge rate ≤0.5 CP Ingress protection IP55
Temperature difference <2.5°C (battery cells) Dimensions W × D × H 6058 × 2438 × 2896 mm
Container format 20 ft Rated battery energy 5015.96 kWh
External protocol Modbus TCP Nominal DC voltage 1331.2 V
Altitude ≤3000 m Packaging Details Container transport, lifting plan and shipping arrangements confirmed for the project.
Brand Name YINTU Model Number YT-Utility ESS-5015kWh
High Light 5015 kWh Liquid Cooled Utility BESS ,314 Ah LFP Utility ESS Container ,C4 Corrosion Protected Utility BESS

UTILITY-SCALE DC BATTERY STORAGE

5015 kWh Liquid-Cooled DC Battery Container in a 20 ft Format

A compact 5015.96 kWh LFP battery platform using 314 Ah cells and liquid cooling for large solar and grid storage projects. Narrow cold plates and 314 Ah cells provide approximately 5 MWh in a 20 ft high-cube container. The stated container footprint is below 15 m²; the complete plant still needs service clearances, fire separation, PCS equipment and access roads.

Equipment and Supply Scope

This listing covers the DC-side battery container, including LFP batteries, battery management, thermal management, DC distribution and the specified protection systems. It is not a complete AC-connected power station. PCS, plant EMS/PPC, transformers, switchgear and grid connection equipment are separate project items unless expressly included in the agreed supply scope.

YINTU is an energy storage solution provider. We work with manufacturing partners to select battery equipment and coordinate the interfaces required for each project.

YT-Utility ESS-5015kWh application concept
Illustrative 20 ft battery-container application concept. External conversion and grid equipment are project-specific; this is not a completed-project photograph.

Grid and Renewable Energy Applications

Large photovoltaic projects with constrained battery layouts

Use a compact battery block to plan energy storage beside a solar collector station. Stored solar energy can be dispatched after the production peak through the separately selected PCS. Container density supports layout planning, but does not replace a full fire, foundation, lifting and maintenance-access study.

Renewable output smoothing and dispatch control

A coordinated PCS and plant EMS can charge or discharge the battery to moderate short-term variations in photovoltaic or wind output and follow an export schedule. The achievable ramp rate and response depend on converter capability, communications, available state of charge and the grid operator’s requirements.

Frequency regulation and operating reserves

The battery supplies or absorbs active energy when the selected PCS and controller respond to a regulation signal. Reserve availability must respect battery voltage, temperature, charge/discharge limits and state of charge. Frequency response is a complete-system function, not a standalone guarantee from the battery enclosure.

Peak management at a grid connection

Discharging during defined high-load intervals can reduce the peak power requested from a connection or support a constrained node. Suitability depends on the local load profile, connection limit and required duration. Any infrastructure-deferral or revenue case needs a project study; the battery rating alone does not establish the result.

System Features and Project Value

A defined energy block for plant design

Narrow cold plates and 314 Ah cells provide approximately 5 MWh in a 20 ft high-cube container. The stated container footprint is below 15 m²; the complete plant still needs service clearances, fire separation, PCS equipment and access roads.

Liquid cooling for thermal consistency

Water-and-glycol cooling is specified with a temperature difference of <2.5°C (battery cells). Narrow cold plates and active balancing support the compact architecture. Thermal performance contributes to consistent operation; it does not eliminate degradation or replace operating limits.

Layered electrical and fire protection

Pack, cluster, battery-bank and system-level fuse protection is described, together with cell-to-cluster insulation, pack/container sensing, gas and water suppression, active exhaust and explosion venting. Final equipment, water interfaces and fire strategy are confirmed with the manufacturing partner and site designers.

Maintainability and operating visibility

AI-based remaining-life and safety-risk prediction, active balancing and automatic cluster switching are described as maintenance-support features. The non-walk-in enclosure allows external maintenance. Monitoring supports inspection and planning but is not a guarantee of uninterrupted availability.

How the System Fits Your Site

In the illustrated AC-coupled example, the battery DC output connects to a compatible bidirectional PCS, then through the project transformer and switchgear to the grid. A photovoltaic plant connects through its own inverter and interface equipment to the AC collector. Plant EMS/PPC coordinates dispatch and exchanges status with the BMS. This battery container does not connect directly to PV strings or the AC grid. Alternative architectures require an approved project design.

YT-Utility ESS-5015kWh conceptual system topology
Concept diagram only. Follow the approved single-line diagram and installation documents.

Technical Specifications

Battery and DC Ratings

Parameter Specification
Model YT-Utility ESS-5015kWh
Cell chemistry / specification LFP / 3.2 V / 314 Ah
Rated battery energy 5015.96 kWh; P2 at 25 ±3°C
Nominal DC voltage 1331.2 V
Battery voltage range 1164.8–1497.6 V
Charge / discharge rate ≤0.5 CP
Source maximum charge / discharge power 2500 kW; configuration reference, not guaranteed AC export
Battery charging temperature 0 to +50°C
Battery discharging temperature −20 to +55°C
Recommended ambient temperature 25 ±10°C
Cycle life ≥6000 cycles; 25 ±10°C; 90% DOD; 80% EOL

Thermal Management and Protection

Parameter Specification
Cooling method / medium Liquid cooling / water + glycol
Temperature difference <2.5°C (battery cells)
BMS architecture 3-level
Auxiliary power supply Approx. 40 kW; 400 V / 50 Hz; 3N + PE
Fire suppression Perfluorohexanone + water; S-type aerosol / HFC-227EA optional
Ingress protection IP55
Corrosion protection C4; C5 optional
Lightning protection Level II

Environment and Enclosure

Parameter Specification
System operating temperature −20 to +50°C; derating above 45°C
Storage conditions −20 to +55°C; less than 6 months
Operating humidity 0–95% RH; non-condensing
Altitude ≤3000 m
Installation Outdoor; non-walk-in external maintenance
Daily duty Up to 2 charges and 2 discharges per day
Dimensions (W × D × H) 6058 × 2438 × 2896 mm (20 ft)
Approximate weight 41 t

Interfaces and Project Scope

Parameter Specification
Communication interfaces CAN / Ethernet / RS485
External communication protocol Modbus TCP
PCS and AC grid connection Separately specified project equipment
Plant EMS / PPC Project-level control scope to be confirmed
Standards listed in source GB/T 36276; GB/T 34131

Auxiliary AC supply ratings describe internal service power, not AC export capability. “CP” and “P2” are source designations retained without reinterpretation. Nameplate battery energy is not guaranteed usable AC energy. Standards are source references; confirm certificates and test-report scope for the supplied configuration. The source describes an AC-coupled configuration using 215 kW modular PCS units. This listing is for the DC battery container; PCS inclusion, topology and the 2500 kW configuration rating require separate project agreement.

From Project Requirements to a Storage Plant

1. Define power, energy and dispatch

Use generation and grid-dispatch profiles to define AC power, usable energy, delivery duration and reserve commitments. Evaluate auxiliary demand, conversion losses, temperature derating and the agreed end-of-life capacity target.

2. Match equipment and site design

YINTU coordinates battery and PCS interface reviews with manufacturing partners. Check the full DC voltage window, communications, grid requirements, foundations, lifting access, corrosion conditions and maintenance clearances.

3. Confirm the project scope

Confirm the battery supply boundary, external PCS, plant EMS/PPC, transformer, switchgear, protection, auxiliary power, civil works, fire design and commissioning responsibilities. Grid connection and local approvals are project-specific.

Frequently Asked Questions

Does this product include a grid-connected inverter?

The published scope is the DC battery container. A compatible PCS and the required AC/MV interface are specified separately. The auxiliary AC supply does not make the container a standalone grid-connected system.

Can solar panels connect directly to the battery container?

No direct PV-string interface is offered in this listing. Solar integration requires the appropriate PV inverter or DC conversion architecture, protection and plant controls. The illustrated scheme is one possible AC-coupled arrangement.

How many containers and how much PCS power are needed?

Start with the required AC MW, usable MWh, dispatch duration and end-of-life target. Account for the usable SOC window, conversion losses, auxiliary demand, temperature derating and reserve commitments. Select the converter against the entire battery voltage window and the agreed charge/discharge limits.

Can it provide backup, grid-forming or black-start operation?

These functions require a specifically engineered complete system, including suitable PCS controls, auxiliary-power arrangements, protection and an approved operating sequence. They are not standalone capabilities guaranteed by this DC battery container.

Is the listed cycle life a warranty?

No. The ≥6000-cycle figure applies under the stated test conditions, depth of discharge and end-of-life threshold. Warranty terms and expected degradation for the actual operating profile require a separate agreement.

Plan Your Utility-Scale Battery Storage Project

Share the required AC power and usable energy, solar generation profile, grid connection voltage, dispatch schedule, site climate and available layout. YINTU can coordinate battery selection, PCS matching and technical clarification with manufacturing partners for a defined project scope.

Parameters are based on the supplied model datasheet and remain subject to final technical confirmation. Illustrations show application concepts, not completed YINTU projects. Listed standards require configuration-specific documentation; cycle life and design life are not warranty commitments.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Exporter,Trading Company

  • Year Established:

    2016

  • Total Annual:

    $ 10 million-$ 20,million

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with... Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with...

+ Read More

Get in touch with us

  • Reach Us
  • Hunan Yintu New Materials Co., Ltd.
  • 201, Building B6, Xinggongchang Industrial Park, No.1 Lantian North Road, Economic Development Zone, Changsha, Hunan, China
  • https://www.yintuenergy.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement