| AC Rated Voltage | 690 V; final PCS scope to be confirmed |
| Wired Interfaces | LAN / CAN / RS485 |
| Monitoring | Real-time cloud monitoring; service scope per project |
| Packaging Details | Containerized equipment; transport protection, lifting and shipping scope agreed per project |
| Rated Power | 2.5 MW; datasheet rating |
| System Platform | 1500 V class |
| Fire Suppression | Integrated gas and water devices |
| Configuration | Final enclosure and equipment arrangement per approved design |
| Battery Chemistry | LiFePO4 (LFP) |
| DC Rated Voltage | 1331.2 V |
| Ingress Protection | IP54 |
| Application | Utility dispatch / renewable energy shifting |
| DC Voltage Range | 1164.8-1497.6 V |
| Communication Protocol | Modbus TCP |
| Cooling Method | Liquid cooling |
| Noise | <65 dB at 1 m |
| Rated Energy | 5.016 MWh |
| Enclosure Protection | C4H, as stated in the datasheet |
| Cell Capacity | 314 Ah |
| Solution Provider | YINTU |
| Delivery Time | Confirmed after configuration approval |
| System Weight | 45,000 kg |
| Brand Name | YINTU |
| Model Number | YT-Container ESS-5016kWh |
View Detail Information
Explore similar products
3.44 MWh Liquid-Cooled Utility ESS with 1.725 MW Rated Power
3290 kWh Utility Scale Battery Energy Storage Systems Modular 20 Foot Battery
3.85 MWh Liquid Cooled Utility Scale ESS With 2 MW Rated Power IP54 Protection
5017 KWh Utility Scale Energy Storage Systems Liquid Cooled For Large Solar
Product Specification
| AC Rated Voltage | 690 V; final PCS scope to be confirmed | Wired Interfaces | LAN / CAN / RS485 |
| Monitoring | Real-time cloud monitoring; service scope per project | Packaging Details | Containerized equipment; transport protection, lifting and shipping scope agreed per project |
| Rated Power | 2.5 MW; datasheet rating | System Platform | 1500 V class |
| Fire Suppression | Integrated gas and water devices | Configuration | Final enclosure and equipment arrangement per approved design |
| Battery Chemistry | LiFePO4 (LFP) | DC Rated Voltage | 1331.2 V |
| Ingress Protection | IP54 | Application | Utility dispatch / renewable energy shifting |
| DC Voltage Range | 1164.8-1497.6 V | Communication Protocol | Modbus TCP |
| Cooling Method | Liquid cooling | Noise | <65 dB at 1 m |
| Rated Energy | 5.016 MWh | Enclosure Protection | C4H, as stated in the datasheet |
| Cell Capacity | 314 Ah | Solution Provider | YINTU |
| Delivery Time | Confirmed after configuration approval | System Weight | 45,000 kg |
| Brand Name | YINTU | Model Number | YT-Container ESS-5016kWh |
| High Light | 5.016 MWh Liquid Cooled Utility ESS ,IP54 Rating Utility ESS ,5.016 MWh Utility Scale Energy Storage Systems | ||
UTILITY-SCALE ENERGY STORAGE SOLUTIONS
5.016 MWh liquid-cooled LFP storage with 2.5 MW rated power, IP54 protection and Modbus TCP communication. For utility dispatch, renewable energy shifting and large industrial projects; final equipment scope is project-specific.
The 5.016 MWh configuration combines 314 Ah LFP cells with a stated 2.5 MW power rating and a 1331.2 V rated DC bus. It provides the largest energy block in these three configurations for developers assessing large solar-plus-storage plants and scheduled grid dispatch. Its 45,000 kg source weight makes transport, lifting and foundation planning an early design consideration.
YINTU is an energy storage solution provider. We work with capable manufacturing partners to match battery equipment, clarify technical interfaces and coordinate a defined supply proposal for developers, EPCs and project owners.
Large battery modules and an integrated architecture support coordinated installation, operation and maintenance. A defined block helps EPC teams plan repeated equipment interfaces across a larger plant; final dimensions, equipment arrangement and service access follow the approved drawing.
Liquid cooling provides the thermal-management approach for the selected LFP configuration. The project review should establish ambient operating limits, cooling auxiliaries, maintenance access and operating setpoints. The supplied sheet does not state a universal temperature-uniformity or cycle-life guarantee.
The source describes multiple balancing measures and integrated gas and water fire-suppression devices. These features form part of the equipment protection strategy. Site fire design, detection interfaces, water connections and emergency procedures are coordinated for the installation.
Multidimensional battery analysis supports fault location, while real-time cloud monitoring provides operating visibility. LAN, CAN and RS485 interfaces with Modbus TCP support integration planning. Remote access, communications mapping, cloud service and cybersecurity requirements are agreed for the project.
C4H enclosure protection and an enclosure service-life claim exceeding 15 years are listed in the source. These describe the enclosure and must not be treated as a battery capacity warranty. Confirm site conditions, protective-coating documentation and maintenance requirements for the destination.
Plan multi-MWh storage alongside a solar collector system to extend energy delivery beyond the production peak. The 5.016 MWh block can support energy-block sizing, while usable AC delivery is calculated from the agreed SOC window, reserve, efficiency and auxiliary consumption. The final plant layout must include converter equipment, access and project-specific safety clearances.
Charge and discharge under an approved operating schedule to align stored energy with grid demand. The project value comes from flexibility in when energy is delivered. Market rules, tariff structures, interconnection limits and degradation assumptions determine the business case; equipment ratings alone do not establish revenue.
With a suitable PCS, plant controller and approved connection scheme, battery storage can be assessed for active-power regulation and reserve duties. Maintain sufficient state-of-charge and power headroom for the contracted service. Response performance and service eligibility belong to the complete system and require project validation.
Combine onsite generation and storage to shift energy toward production periods and manage selected demand peaks. Coordinate the storage schedule with plant operations, connection capacity and any reserved energy. Backup or island operation requires a separately verified control and protection design.
In an AC-coupled concept, the battery DC system exchanges energy with a bidirectional PCS. The AC side connects through project-selected transformer, switchgear, metering and protection equipment to the grid or site bus. A solar plant connects through its PV inverter. Plant EMS/PPC coordinates dispatch while exchanging battery status and limits with the BMS.
| Parameter | Specification |
|---|---|
| Model | YT-Container ESS-5016kWh |
| Battery type | LFP 314 Ah |
| Rated energy | 5.016 MWh (5016 kWh) |
| Rated power | 2.5 MW |
| DC rated voltage | 1331.2 V |
| DC voltage range | 1164.8-1497.6 V |
| AC rated voltage | 690 V |
| System platform | 1500 V class |
| DC-side efficiency | Up to 93%; source claim, test conditions not specified |
| Maximum system efficiency | >89%; source wording, test boundary not specified |
| Parameter | Specification |
|---|---|
| System weight | 45,000 kg |
| IP protection level | IP54 |
| Cooling type | Liquid cooling |
| Noise | <65 dB at 1 m from the system |
| Wired communication interfaces | LAN / CAN / RS485 |
| Communication protocol | Modbus TCP |
| Enclosure protection | C4H, as stated in the source |
| Enclosure service life | Over 15 years; enclosure design claim, not battery-life or warranty term |
| Fire suppression | Integrated gas and water devices |
| Monitoring | Multidimensional battery analysis and real-time cloud monitoring |
| Dimensions and operating environment | Not specified in this datasheet; confirm installation drawing and limits |
The 1500 V platform description is a voltage class, not the nominal DC voltage. The 93% DC-side figure and >89% system-efficiency figure have different source descriptions and are retained separately; no AC round-trip efficiency is inferred. Rated energy is not guaranteed usable AC energy. The source lists 690 V AC but does not define the PCS location or a complete bill of supply. Confirm PCS inclusion, transformer, switchgear, plant EMS/PPC and site interfaces in the technical agreement.
Standards listed in the supplied series datasheet: IEC/EN 62477, NFPA 855, IEC/EN 62619, IEC/EN 60730, IEC/EN 63056, UL 1973 and UL 9540A. Confirm model-specific certificates, test reports and their scope. These references do not replace the applicable site design, utility interconnection process or local approvals.
Prioritize the total plant energy target, transport route, lifting capacity and foundation design. Review the upper DC operating voltage of 1497.6 V against the selected converter and protection equipment.
Share the target AC MW and usable MWh, generation or load profile, grid connection voltage, operating schedule, climate and available site layout. YINTU coordinates equipment selection and technical clarification with manufacturing partners. The proposal defines included batteries, cooling, protection, controls, conversion equipment and project accessories. Installation, commissioning, transport, civil works and grid connection services are included only where agreed.
The sheet specifies rated system power and 690 V AC but does not provide a complete equipment list or PCS arrangement. YINTU will confirm the battery, PCS, controls, transformer and switchgear boundaries in the project proposal. Do not treat the illustration as proof of included conversion equipment.
No direct PV-string or MPPT input is specified. Solar integration requires a project-selected PV inverter or another approved conversion architecture, protection and coordinated controls. The diagram shows an AC-coupled concept.
Actual duration depends on the load or dispatch power, usable SOC window, reserve requirements, conversion and auxiliary losses, operating temperature and end-of-life target. Nominal MWh divided by MW is a planning ratio, not a guaranteed delivered duration.
These functions are not specified in the supplied datasheet. They require suitable conversion equipment, control functions, auxiliary-power arrangements and an approved operating sequence. Confirm them as explicit project requirements.
The datasheet lists standards, but a listing does not establish certification of every supplied configuration. Request model-specific certificates and test reports, including their versions, applicable equipment and test scope.
Send YINTU your project location, power and energy targets, site data and delivery schedule. We will coordinate a suitable configuration and a clear technical and commercial proposal with our manufacturing partners.
Technical source: YT-Container ESS-5016kWh datasheet, V1.0, October 2026. Series illustration; final enclosure and equipment configuration may vary by model. Original datasheet attached. Final specifications and supply boundaries follow the approved project agreement.
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company
Year Established:
2016
Total Annual:
$ 10 million-$ 20,million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with... Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with...
Get in touch with us
Leave a Message, we will call you back quickly!