Model No. | YF-B090 |
Brand | YUKA |
Material | Aluminum Alloy |
Housing Serve Lige | 15 Years |
Element Serve Life | 6000~8000 Hours |
Maxi. Operate Pressure | 1.6 Mpa |
Operate Temperature | 1.5~80ºc |
Connection | Rc2" |
Filtration Performance | From 5 μm To 0.01μm |
Resistance Corrosion | Inside And Outside |
Filter Type | Coalescing |
Option Parts | Connection Kit |
Configuration | Manual Ball Valve |
Element Top Cap | Diversion Fin Less Pressure Loss |
Element Top Cap Color | Colorful To Distinguish |
Color | Light Blue |
Transport Package | Brown Inner Box & Cardboard |
Specification: Dimension | 174 X 142x 558mm |
HS Code | 8421399090 |
Clapboard | Without Clapboard |
Filter Number | 1 |
Medium Material | Fiberglass |
Filtration Grade | Medium Filter |
Type | Cartridge Filter |
Efficiency | F9 |
Flow Rate | 10 M³/Min |
Packaging Details | Box Package |
Delivery Time | 3-7working days |
Payment Terms | L/C,T/T |
Supply Ability | 300,000pcs/month |
Place of Origin | China |
Brand Name | Yuka |
View Detail Information
Explore similar products
1/2 Inch coalescing air filter 1.8m3/min
Compressed air filtration with 0.01 micron
Active Carbon Air Filter Cartridge Replacement
Coalescant Air Filter Precision Filter Industry Gas Filter
Product Specification
Model No. | YF-B090 | Brand | YUKA |
Material | Aluminum Alloy | Housing Serve Lige | 15 Years |
Element Serve Life | 6000~8000 Hours | Maxi. Operate Pressure | 1.6 Mpa |
Operate Temperature | 1.5~80ºc | Connection | Rc2" |
Filtration Performance | From 5 μm To 0.01μm | Resistance Corrosion | Inside And Outside |
Filter Type | Coalescing | Option Parts | Connection Kit |
Configuration | Manual Ball Valve | Element Top Cap | Diversion Fin Less Pressure Loss |
Element Top Cap Color | Colorful To Distinguish | Color | Light Blue |
Transport Package | Brown Inner Box & Cardboard | Specification: Dimension | 174 X 142x 558mm |
HS Code | 8421399090 | Clapboard | Without Clapboard |
Filter Number | 1 | Medium Material | Fiberglass |
Filtration Grade | Medium Filter | Type | Cartridge Filter |
Efficiency | F9 | Flow Rate | 10 M³/Min |
Packaging Details | Box Package | Delivery Time | 3-7working days |
Payment Terms | L/C,T/T | Supply Ability | 300,000pcs/month |
Place of Origin | China | Brand Name | Yuka |
Installation method of Compressed Air Filter
①Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.
②The Filter Element should be replaced regularly. When replacing the filter element, use an Allen wrench to unscrew the four screws of the lower cover and take out the old filter element from below. Carefully record the replacement time. It is recommended that the working time z should not exceed 8000 hours.
③The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;
④Different grades of compressed Air Filters can be equipped with electronic drain valves or manual valves according to customer requirements.
7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Product Picture
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H (Height) | A | B | C(clearance for housing) | ||
YFB010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 357 | 37 | 320 | 208 |
YFB070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 902 | 74 | 828 | 764 |
YFB160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 902 | 74 | 828 | 764 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
10000000-50000000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work... Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work...
Get in touch with us
Leave a Message, we will call you back quickly!