Model No. | YF-B030 |
Brand | YUKA |
Origin | China |
Element Serve Life | 6000~8000 Hours |
Trademark | Yuka |
HS Code | 8421399090 |
Clapboard | Without Clapboard |
Flow Rate | 1.8 M³/Min |
Medium Material | Fiberglass |
Connection Size | Rc3/4" |
Material | Aluminum Alloy |
Housing Serve Lige | 15 Years |
Filtration Performance | From 5 μm To 0.01μm |
Operate Temperature | 1.5~80ºc |
Resistance Corrosion | Inside & Outside |
Transport Package | Brown Inner Box & Cardboard |
Efficiency | F9 |
Filtration Grade | Medium Filter |
Maxi. Operate Pressure | 1.6 Mpa |
Belong To | Air Compressor System |
Filter Type | Coalescing |
Option Parts | Connection Kit |
Configuration | Manual Ball Valve |
Element Top Cap | Diversion Fin |
Filter Number | 1 |
Dimension | 96 X 79x 286mm |
Type | Cartridge Filter |
Packaging Details | Box Package |
Delivery Time | 3-7working days |
Payment Terms | L/C,T/T |
Supply Ability | 300,000pcs/month |
Place of Origin | China |
Brand Name | Yuka |
View Detail Information
Explore similar products
Yuka Brand Air Compressor Inline Filter
YD-B058 dust air filters for adsorption dryer
compressed air line filter for air compressor
Quality active carbon air filter for air dryers
Product Specification
Model No. | YF-B030 | Brand | YUKA |
Origin | China | Element Serve Life | 6000~8000 Hours |
Trademark | Yuka | HS Code | 8421399090 |
Clapboard | Without Clapboard | Flow Rate | 1.8 M³/Min |
Medium Material | Fiberglass | Connection Size | Rc3/4" |
Material | Aluminum Alloy | Housing Serve Lige | 15 Years |
Filtration Performance | From 5 μm To 0.01μm | Operate Temperature | 1.5~80ºc |
Resistance Corrosion | Inside & Outside | Transport Package | Brown Inner Box & Cardboard |
Efficiency | F9 | Filtration Grade | Medium Filter |
Maxi. Operate Pressure | 1.6 Mpa | Belong To | Air Compressor System |
Filter Type | Coalescing | Option Parts | Connection Kit |
Configuration | Manual Ball Valve | Element Top Cap | Diversion Fin |
Filter Number | 1 | Dimension | 96 X 79x 286mm |
Type | Cartridge Filter | Packaging Details | Box Package |
Delivery Time | 3-7working days | Payment Terms | L/C,T/T |
Supply Ability | 300,000pcs/month | Place of Origin | China |
Brand Name | Yuka |
Features & Benefit
①Unique aluminum alloy with die-casting integrated technology, filter housing with 15 years warranty.
②Spin Element is compatible with lubrcants.Multi-wrap borosilicate fiber glass media, ensure filtration accuracy up to ISO8573.1-2010.
③100% leak-tested in three times
④Low pressure drop, saving energy and cost for ownership
⑤Manual Drain Valve
Element Specification
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21℃),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21℃),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21℃),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the Compressed Air Filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Size of solid particles(ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Filtration performance of solid particles(ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil(ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Residual oil content(ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Product Picture
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W (Width) | D (Depth) | H (Height) | A | B | C (clearance for housing) | ||
YFB010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 357 | 37 | 320 | 208 |
YFB070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 902 | 74 | 828 | 764 |
YFB160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 902 | 74 | 828 | 764 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
10000000-50000000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work... Hongrijia Depurate Facility Science & Technology Co.,Ltd. was found in China Shenzhen since 1998. YUKA is our brand, we dedicated in Compressed Air Treatment,New Delhi, South American and Middle-est has subsidiary and sales center. With 12000 square meter in Huizhou for Compressed air dryer work...
Get in touch with us
Leave a Message, we will call you back quickly!