| Payment Terms | T/T,L/C |
| Model | Feyond-L100 |
| Packaging Details | carton |
| Wavelength Range | 200–850 nm |
| Supply Ability | 500pcs/month |
| Detection Mode | Glow and flash luminescence |
| Linear Dynamic Range | 7 logs for flash ATP assays |
| Product Type | Luminescence Microplate Reader |
| Delivery Time | 15 days |
| Supported Microplates | 6- to 384-well microplates |
| Detection Limit | 5 amol/well under optimized conditions |
| Standard Filters | 470 nm and 560 nm |
View Detail Information
Explore similar products
APW-200 96 Well Plate Washer Automatic Microplate Washer For ELISA Plates
96-Well ELISA Microplate Reader With Touchscreen Absorbance Detection
UV-Vis Absorbance Microplate Reader With Monochromator 200–1000Nm
Top Reading Fluorescence Microplate Reader For Cell Based And Nucleic Acid
Product Specification
| Payment Terms | T/T,L/C | Model | Feyond-L100 |
| Packaging Details | carton | Wavelength Range | 200–850 nm |
| Supply Ability | 500pcs/month | Detection Mode | Glow and flash luminescence |
| Linear Dynamic Range | 7 logs for flash ATP assays | Product Type | Luminescence Microplate Reader |
| Delivery Time | 15 days | Supported Microplates | 6- to 384-well microplates |
| Detection Limit | 5 amol/well under optimized conditions | Standard Filters | 470 nm and 560 nm |
| High Light | 384 Well Luminescence Microplate Reader ,Luciferase Assays Luminescence Microplate Reader ,6 Well luminescence plate reader | ||
The Feyond-L100 is a compact luminescence microplate reader designed for sensitive glow and flash luminescence assays. It supports 6- to 384-well microplates and uses a low-noise photomultiplier tube to detect weak light signals.
The Feyond-L100 Luminescence Microplate Reader is developed for laboratories performing sensitive chemiluminescence and bioluminescence assays.
A low-noise PMT detector provides high sensitivity across a wavelength range of 200-850 nm. The system supports both glow and flash measurements, with a linear dynamic range of up to seven logs for flash ATP assays. Its optical design limits well-to-well crosstalk to no more than 0.05%, helping improve data reliability in high-density plates.
The standard 470 and 560 nm filters help reduce background noise during luciferase reporter gene measurements. Other filter wavelengths can be configured according to specific assay requirements.
An optional single or dual automatic injector can dispense reagents directly into 96- or 384-well plates. The injector and detection module work together to capture rapid luminescence signals immediately after reagent addition, making the system suitable for flash-type reactions.
The 10-inch touchscreen and built-in software allow the instrument to operate independently without a computer. Users can create plate layouts, set measurement parameters, analyze data and save assay programs directly on the reader. PC software and FTP data transfer are also supported.
The instrument also provides microplate shaking and temperature-controlled incubation from room temperature plus 4°C to 45°C.
The Feyond-L100 is suitable for universities, research institutes, biotechnology companies and pharmaceutical research laboratories. Actual detection performance depends on the reagent system, microplate type, injector settings and assay conditions.
| Luminescence Detection Parameters | ||
|---|---|---|
| Parameter | Specification | |
| Detector | PMT | |
| Detection Limit | 5 amol/well under optimized conditions | |
| Linear Dynamic Range | 7 logs for flash ATP assays | |
| Crosstalk | ≤0.05% | |
| Wavelength Range | 200-850 nm | |
| Standard Filters | 470 nm and 560 nm | |
| Measurement Types | Glow and flash luminescence | |
| Basic Parameters | ||
|---|---|---|
| Category | Parameter | Specification |
| Plate Support | Supported Plates | 6- to 384-well microplates |
| Accessories | Injector | |
| Shaking and Incubation | Shaking Modes | Linear, annular and double annular |
| Incubation Temperature | Room temperature +4°C to 45°C | |
| Temperature Uniformity | ±0.5°C at 37°C | |
| Software | Software Interface | Chinese/English |
| Screen Size | 10-inch | |
| Operation Method | Capacitive touchscreen and mouse | |
| Data Capacity | 10 GB | |
| PC Compatibility | ReaderIt-II PC software | |
| Network Transmission | Test reports can be uploaded to a PC server through FTP | |
| Others | Instrument Ports | 2 × USB Type-A, 1 × USB Type-B, 1 × Ethernet and RS232 injector interface |
| Power Supply | AC 100-240 V, 50/60 Hz | |
| Dimensions (W × D × H) | 420 × 487 × 318 mm | |
| Weight | 30 kg | |
| Standard Filter Configuration | ||
|---|---|---|
| Filter | Wavelength | Typical Purpose |
| LUM-470 | 470 nm | Background reduction for selected luminescence assays |
| LUM-560 | 560 nm | Background reduction for luciferase-based assays |
Company Details
Business Type:
Manufacturer
Year Established:
2021
Total Annual:
10000000-50000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
About Us:Shanghai Yukey Technology Co., Ltd. is a professional manufacturer and supplier of laboratory instruments and equipment, dedicated to providing high-quality, reliable and innovative solutions for laboratories worldwide. With years of experience in the industry, we have built a strong reputa... About Us:Shanghai Yukey Technology Co., Ltd. is a professional manufacturer and supplier of laboratory instruments and equipment, dedicated to providing high-quality, reliable and innovative solutions for laboratories worldwide. With years of experience in the industry, we have built a strong reputa...
Get in touch with us
Leave a Message, we will call you back quickly!