| Payment Terms | T/T,, Western Union,Paypal |
| Supply Ability | 200 Pieces Per Month |
| Delivery Time | 3 - 7 Days |
| Packaging Details | Standard Export Wooden Box |
| Accuracy class | 0.05%, 0.1% |
| AC Current output Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
| Harmonic Harmonic times | 2nd-63th |
| Load capacity | 40VA |
| Temperature drift | 8 PPM/°C |
| Weight (kg) | 12 |
| Brand Name | GFUVE |
| Model Number | GF101 |
| Certification | ISO |
| Place of Origin | China |
View Detail Information
Explore similar products
Multi-Phase Secondary Current Injection Protection Relay Test System With
100A Three Phase Secondary Current Injection test equipment for Energy meter or
High Precision Protection Relay Testing Equipment / Protective Relay Test Set DC
Three Phase Secondary Injection Test Kit Universal Protection Device High
Product Specification
| Payment Terms | T/T,, Western Union,Paypal | Supply Ability | 200 Pieces Per Month |
| Delivery Time | 3 - 7 Days | Packaging Details | Standard Export Wooden Box |
| Accuracy class | 0.05%, 0.1% | AC Current output Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
| Harmonic Harmonic times | 2nd-63th | Load capacity | 40VA |
| Temperature drift | 8 PPM/°C | Weight (kg) | 12 |
| Brand Name | GFUVE | Model Number | GF101 |
| Certification | ISO | Place of Origin | China |
| High Light | secondary injection test kit ,protection relay testing equipment | ||
Program-controlled Single Phase Phantom Load Power Source
1 . Setting up and taking the load regulation of voltage, current, phase and frequency of the power factor
2 . Amplitude 2nd-128th phase harmonics, and it can be added to the fundamental wave in every harmonic output
3 . A wide range output of voltage and current, big power, high stability, small waveform distortion degree
4 . Strong load ability, taking capacitive load, sensibility load, resistive load or composite load, load regulation is higher than 0.01%
5 . Applying the 32-bit MPU + DSP + FPGA, powerful flexible;
6 . Using hardware PID, fast response, the change of load will not cause volatility output.
7 . Power frequency waves reach up to 50000 points a week of the wave kneading, signal output without filter, precise waveform output, precise harmonic output, small harmonic distortion degree
Parameters
| Electrical parameters | |
| Accuracy class | 0.05%, 0.1% |
| Power supply | Single phase AC 85-265V, 50/60 Hz |
| AC Voltage output | |
| Range | 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
| Accuracy | 0.05% RG |
| Stability | Better than 0.01% RG / 1 min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 40VA |
| Full load regulation rate | Less than 0.01% RG |
| Full load regulation time | Less than 1ms |
| Temperature drift | 8 PPM / °C |
| Long-term stability | 60 PPM/year |
| AC Current output | |
| Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
| Accuracy | 0.05% RG |
| Stability | Better than 0.01% RG/1 min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 40VA |
| Full load regulation rate | Less than 0.01% RG |
| Full load regulation time | Less than 1mS |
| Temperature drift | 8 PPM / °C |
| Long-term stability | 60 PPM/year |
| Power output | |
| Active power accuracy | 0.05% or 0.1% |
| Reactive power accuracy | 0.1% or 0.2% |
| Stability | Better than 0.01% RG / 1 min |
| Phase | |
| Range | 0°-359.99° |
| Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
| Accuracy | 0.03° |
| Frequency | |
| Range | 40-65 Hz |
| Adjustment resolution | 0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz |
| Accuracy | 0.002 Hz |
| Temperature drift | 0.5 PPM / °C |
| Long-term stability | 4 PPM/year |
| Harmonic | |
| Harmonic times | 2nd-63th |
| Adjustment resolution | 0.1% (Compared with fundamental wave) |
| Harmonic content (Compared with fundamental wave) | |
| Voltage | ≤ 40% |
| Current | ≤ 40% |
| Phase | 0°-360° |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 420x320x155 |
| Weight (kg) | 12 |
| Environmental conditions | |
| Operating temperature | 0°C to 40°C |
| Storage conditions | -30°C to 60°C |
| Relative humidity | ≤85% |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
$100,000,000-$150,000,000
Employee Number:
300~350
Ecer Certification:
Active Member
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...